About Pressure Switches
More
Pressure Switches for Air Compressors


Maintain the air pressure needed for air-powered devices. These switches turn your electric air compressor off when it reaches the set pressure and on when it reaches the reset pressure. All are NEMA rated to protect their parts from dirt and stand up to some corrosion, but they shouldn’t be used outdoors. UL listed and CSA certified, all meet American and Canadian safety standards. Those that are CE marked meet European safety standards.
Switches with an air exhaust valve release the air between the cylinder and check valve when the compressor shuts off, reducing stress on the compressor’s motor. This extends the life of the motor and makes for an easier startup each time.
Switches with plastic housing stand up to corrosion.
For technical drawings and 3-D models, click on a part number.
Max. Horsepower | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Setpoint, psi | Reset Point, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Accuracy | AC (Single Phase) | AC (Three Phase) | DC | Wire Connection Type | Environmental Rating | Each | |
Switches | |||||||||||
Polypropylene Plastic Housing—1/4 NPSF Female Pipe Connection | |||||||||||
20-80 | 5-60 | 22 | 80 | ±3% | 2 hp @ 115 V AC 3 hp @ 230 V AC | 3 hp @ 115 V AC 5 hp @ 230 V AC | 1 hp @ 115 V DC 1 hp @ 230 V DC | Screw Terminals | NEMA 1 | 0000000 | 000000 |
40-100 | 20-80 | 20 | 100 | ±3% | 1 1/2 hp @ 115 V AC 2 hp @ 230 V AC | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | Screw Terminals | NEMA 1 | 0000000 | 00000 |
60-200 | 40-170 | 30 | 200 | ±3% | 2 hp @ 115 V AC 3 hp @ 230 V AC | 3 hp @ 115 V AC 5 hp @ 230 V AC | 1 hp @ 115 V DC 1 hp @ 230 V DC | Screw Terminals | NEMA 1 | 0000000 | 00000 |
100-200 | 60-160 | 40 | 200 | ±3% | 1 1/2 hp @ 115 V AC 2 hp @ 230 V AC | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | Screw Terminals | NEMA 1 | 0000000 | 00000 |
Switches with Air Exhaust Valve | |||||||||||
Polypropylene Plastic Housing—1/4 NPSF Female Pipe Connection | |||||||||||
20-80 | 5-60 | 22 | 80 | ±3% | 2 hp @ 115 V AC 3 hp @ 230 V AC | 3 hp @ 115 V AC 5 hp @ 230 V AC | 1 hp @ 115 V DC 1 hp @ 230 V DC | Screw Terminals | NEMA 1 | 0000000 | 000000 |
40-100 | 20-80 | 20 | 100 | ±3% | 1 1/2 hp @ 115 V AC 2 hp @ 230 V AC | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | Screw Terminals | NEMA 1 | 0000000 | 00000 |
60-200 | 40-170 | 30 | 200 | ±3% | 2 hp @ 115 V AC 3 hp @ 230 V AC | 3 hp @ 115 V AC 5 hp @ 230 V AC | 1 hp @ 115 V DC 1 hp @ 230 V DC | Screw Terminals | NEMA 1 | 0000000 | 000000 |
100-200 | 60-160 | 40 | 200 | ±3% | 1 1/2 hp @ 115 V AC 2 hp @ 230 V AC | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | Screw Terminals | NEMA 1 | 0000000 | 00000 |
Pressure Switches for Water Pumps


Activate or deactivate your electric water pump based on water pressure. These switches turn your pump off when pressure increases to the set pressure and on when pressure drops to the reset pressure. All are NEMA rated to stand up to some corrosion, but they shouldn’t be used outdoors. UL listed and CSA certified, switches meet American and Canadian safety standards.
Use switches with a manual on/off lever to turn off your system for maintenance or for long periods of time. When you turn them back on, they’ll resume pump control and remember their pressure setpoints.
Switches with low-pressure cutoff turn your pump off if water pressure dips 10 psi lower than the reset pressure. This stops the system from pumping when there’s an issue in your line, such as a leak or break, to avoid flooding or other damage. These switches will also resume pump control with their previous setpoints when turned back on.
Switches with pressure surge protection won’t activate during brief periods of high pressure. They’re often used in systems that have frequent pressure spikes.
For technical drawings and 3-D models, click on a part number.
Max. Horsepower | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Setpoint, psi | Reset Point, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Accuracy | AC (Single Phase) | AC (Three Phase) | DC | Wire Connection Type | Environmental Rating | Each | |
Switches with Manual On/Off Lever | |||||||||||
1/2 NPSF Female Pipe Connection | |||||||||||
20-65 | 5-45 | 20 | 65 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | __ | Screw Terminals | NEMA 1 | 00000000 | 000000 |
25-80 | 5-60 | 20 | 80 | ±3% | 2 hp @ 120 V AC 3 hp @ 240 V AC | 3 hp @ 120 V AC 5 hp @ 240 V AC | 1/2 hp @ 120 V DC 1/2 hp @ 240 V DC | Screw Terminals | NEMA 1 | 00000000 | 00000 |
Switches with Manual On/Off Lever and Low-Pressure Cutoff | |||||||||||
1/2 NPSF Female Pipe Connection | |||||||||||
20-65 | 5-45 | 20 | 65 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 1/4 hp @ 240 V AC 1/4 hp @ 120 V DC | Screw Terminals | NEMA 1 | 00000000 | 00000 |
Switches with Pressure Surge Protection | |||||||||||
1/2 NPSF Female Pipe Connection | |||||||||||
20-65 | 5-45 | 20 | 65 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | __ | Screw Terminals | NEMA 1 | 00000000 | 00000 |
Multiport Pressure Switches for Air Compressors
With multiple ports, these switches maintain the air pressure of your electric air compressor, while also including ports for up to three air-powered devices, reducing the complexity of your air system setup. These switches turn off the compressor when it reaches the set pressure and on when the pressure drops to the reset point. They have an air exhaust valve, so when they shut off, they automatically release air between the compressor’s cylinder and check valve. This reduces stress on the motor to extend its life and makes for easier startups. All are NEMA rated to protect from dirt and stand up to some corrosion, but they shouldn’t be used outdoors. UL listed, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
Switches with a manual on/off lever let you turn off your system for maintenance or extended periods of time. When you flip the lever back on, the switch will automatically have the setpoint and reset point from its last use.
Use plugs (sold separately) in ports that are not in use. The NPT threads on the plugs are compatbile with the NPSC threads on the switch.


Max. Horsepower | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Setpoint, psi | Reset Point, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Accuracy | AC (Single Phase) | AC (Three Phase) | DC | Wire Connection Type | Environmental Rating | Each | |
Switches with Air Exhaust Valve | |||||||||||
1/4 NPSC Pipe Connection | |||||||||||
70 -150 | 40 - 120 | 30 | 150 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 1/4 hp @ 120 V DC 1/4 hp @ 240 V DC | Screw Terminals | NEMA 1 | 0000000 | 000000 |
100 -200 | 60 - 160 | 40 | 200 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 1/4 hp @ 120 V DC 1/4 hp @ 240 V DC | Screw Terminals | NEMA 1 | 0000000 | 00000 |
Switches with Air Exhaust Valve and Manual On/Off Lever | |||||||||||
1/4 NPSC Pipe Connection | |||||||||||
70 -150 | 40 - 120 | 30 | 150 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 1/4 hp @ 120 V DC 1/4 hp @ 240 V DC | Screw Terminals | NEMA 1 | 0000000 | 00000 |
100 -200 | 60 - 160 | 40 | 200 | ±3% | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 1/4 hp @ 120 V DC 1/4 hp @ 240 V DC | Screw Terminals | NEMA 1 | 0000000 | 00000 |

Pipe Size | Connection | Each | |
1/4 | NPT Male | 00000000 | 00000 |