About Pressure Switches
More
Electronic Pressure Switches for Compressed Air
With a set pressure range that works for most air systems, these switches send signals when your air system reaches a set pressure to your programmable logic controller (PLC) to activate automated controls and alarms. All meet at least one American, Canadian, or European safety standard.
Monitor your pressure on the display and change your setpoint, reset point, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point.
Add a square panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Setpoint, psi | Approximate Difference Between Setpoint and Reset Point | Max. Continuous Pressure, psi | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | Wire Connection Type | For Use With | Environmental Rating | Each | |
PNP Output | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/8 NPT Male Pipe Connection | |||||||||||
0-145 | Adjustable | 145 | ±0.2% | 25 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Wire Leads | Air, Argon, Nitrogen | IP40 | 0000000 | 000000 |
1/4" Female Push-to-Connect Tube Connection | |||||||||||
0-145 | Adjustable | 145 | ±0.2% | 25 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Wire Leads | Air, Argon, Nitrogen | IP40 | 0000000 | 00000 |
NPN Output | |||||||||||
1/8 NPT Male Pipe Connection | |||||||||||
0-145 | Adjustable | 145 | ±0.2% | 25 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Wire Leads | Air, Argon, Nitrogen | IP40 | 0000000 | 00000 |
1/4" Female Push-to-Connect Tube Connection | |||||||||||
0-145 | Adjustable | 145 | ±0.2% | 25 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Wire Leads | Air, Argon, Nitrogen | IP40 | 0000000 | 00000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Dual-Setpoint Electronic Pressure Switches for Compressed Air
Compatible with most air systems, these switches send digital signals to a programmable logic controller (PLC) to trigger separate processes when they reach either of their two set pressures. For example, they’ll activate a compressor if the pressure is too low or a relief valve if the pressure is too high. Or use them to signal an alarm before switching off a compressor. Some of these switches also work with liquids and gases, so they can be built into hydraulic systems and wet or humid environments, such as cleaning lines.
Monitor your pressure on the display and change your setpoints, reset points, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. Add a panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
Rated IP65, they seal out dust and water from washdowns. Switches are UL and C-UL recognized components and CE marked to meet American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.

Setpoint, psi | Approximate Difference Between Setpoint and Reset Point | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Signal Output Type | Accuracy | Max. Switching Current | Process Temperature Range, ° F | Connection Material | Environmental Rating | Each | |
For Use With Air, Argon, Inert Gas, and Nitrogen | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Leads—1/8 NPT Male Pipe Connection | |||||||||||
15-150 | Adjustable | 150 | 215 | PNP | ±0.2% | 35 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | IP65 | 0000000 | 0000000 |
For Use With Air, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, and Water | |||||||||||
Wire Leads—1/4 NPT Male Pipe Connection | |||||||||||
15-150 | Adjustable | 150 | 290 | PNP | ±0.2% | 35 mA @ 24 V DC | 25° to 120° | 304 Stainless Steel | IP65 | 0000000 | 000000 |
15-300 | Adjustable | 300 | 580 | PNP | ±0.2% | 35 mA @ 24 V DC | 25° to 120° | 304 Stainless Steel | IP65 | 0000000 | 000000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Electronic Vacuum Switches for Compressed Air

Specifically made for air systems, these switches send signals to your programmable logic controller (PLC) to trigger processes when they reach a set vacuum. Use them to turn equipment on or off, activate automated controls, or signal alarms. Check the vacuum on the display and change your setpoint, reset point, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of vacuum change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. All switches meet at least one American, Canadian, or European safety standard.
Add a square panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.
Digital Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Setpoint, in. of Hg | Approximate Difference Between Setpoint and Reset Point | Maximum Continuous Pressure, psi | No. of | Signal Type | Accuracy | Maximum Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Switches | ||||||||||||
Wire Leads—1/8 NPT Male Pipe Connection | ||||||||||||
30-0 | Adjustable | 14.7 | 1 | PNP | ±0.2% | 25 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Air, Argon, Nitrogen | IP40 | 0000000 | 000000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Dual-Setpoint Electronic Vacuum Switches for Compressed Air
Trigger two different processes in vacuum applications by sending signals to a programmable logic controller (PLC) when these switches reach one of their two set vacuums. Designed specifically for air systems, they can turn on a vacuum pump if the vacuum is too low or a valve if the vacuum is too high. Or use them to signal an alarm before switching off a pump. Check the vacuum on the display and change your setpoint, reset point, scaling, and other settings using the buttons. An adjustable reset means you can control the amount of pressure change before the switch resets. This pressure difference is commonly referred to as deadband and differential. Choose anywhere within the setpoint range for your reset point.
Rated IP65, these switches seal out dust and water from light rinses. They meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components as well as CE marked.
Add a square panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Setpoint, in. of Hg | Approximate Difference Between Setpoint and Reset Point | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Signal Output Type | Accuracy | Maximum Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Wire Leads | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/8 NPT Male Pipe Connection | ||||||||||||
30-0 | Adjustable | 14.6 | 72 | PNP | ±0.2% | 35 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Air, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, Water | IP65 | 0000000 | 0000000 |

For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Electronic Pressure and Vacuum Switches for Compressed Air
Designed specifically for air systems, these switches send signals to your programmable logic controller (PLC) to activate controls or alarms when your system reaches a set pressure or vacuum. All meet at least one American, Canadian, or European safety standard.
Monitor pressure, setpoint, and reset point on the digital display. Use the display’s buttons to change your settings. These switches have an adjustable reset point (also called adjustable deadband or differential), so you can control the amount of pressure or vacuum change before the switch resets. Choose anywhere within the setpoint range for your reset point.
Add a panel-mounting bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Setpoint | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Vacuum, in. of Hg | Approximate Difference Between Setpoint and Reset Point | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Accuracy | Maximum Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Switches (PNP) | ||||||||||||
Wire Leads—1/8 NPT Male Pipe Connection | ||||||||||||
0-14.5 | 29-0 | Adjustable | 14.5 | 72 | ±0.2% | 25 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Air, Argon, Inert Gas, Nitrogen | IP40 | 0000000 | 000000 |
For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |
Dual-Setpoint Electronic Pressure and Vacuum Switches for Compressed Air
With two setpoints, these switches trigger different actions in your air system by sending signals to a programmable logic controller (PLC) when they reach one of their set pressures or vacuums. For example, they can activate one light when a system is pressurized and another when it’s under vacuum. They have an adjustable reset, so you can control the amount of pressure change before the switch resets. This pressure difference is also called deadband or differential. Choose a reset point anywhere within the setpoint range.
Easily monitor your pressure or vacuum setpoint on the digital display. Use its buttons to adjust the settings and setpoint.
These switches are rated IP65 to seal out dust and water from light rinses. They’re CE marked, UL and C-UL recognized components, and CSA certified to meet American, Canadian, and European safety standards.
Add a panel-mounting bracket (sold separately) to mount switches to a control panel for easy viewing and adjusting.
For technical drawings and 3-D models, click on a part number.

Setpoint | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Vacuum, in. of Hg | Approximate Difference Between Setpoint and Reset Point | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Signal Output Type | Accuracy | Maximum Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Wire Leads | |||||||||||||
1/8 NPT Male Pipe Connection | |||||||||||||
0-14.5 | 29-0 | Adjustable | 14.5 | 72 | PNP | ±0.2% | 35 mA @ 24 V DC | 25° to 120° | Nickel-Plated Brass | Air, Argon, Inert Gas, Nitrogen | IP65 | 0000000 | 0000000 |

For Panel Cutout | ||||
---|---|---|---|---|
Ht. | Wd. | Mounting Hole Style | Each | |
1 7/32" | 1 7/32" | Straight | 0000000 | 00000 |