    7 Products

    Pressure Switches for Oxygen

    Cleaned to ASTM G93 requirements and then bagged, these switches meet the strict cleaning standards required for oxygen service lines. Removing all contaminants extends the life of the switch and helps maintain a safe environment.
    When a set pressure is reached, these switches can turn equipment on and off, activate automated controls, or signal alarms. They have an internal setpoint adjustment with a sliding cover to prevent accidental setting changes. They’re single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    NEMA rated, they seal out dust and water from washdowns and the weather. These switches also meet UL 508, are CE marked, and are UL and C-UL recognized components, so they meet American, Canadian, and European safety standards.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Oxygen.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K120000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K14000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K16000000
     
    1/4 Threaded NPT Male Pipe
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K17000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K18000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K19000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K21000000
     