McMaster-Carr logo
    Filter by
    System of Measurement
    Pipe Size
    Industrial Info Compare
    Thread Type
    Operates On
    Switch Starting Position
    Industrial Info Compare
    Set Point Adjustability
    Connection Material
    Fitting Connection
    Connects To
    Gender
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    35 Products

    Compact Pressure Switches

    With a round body that’s at least one-third thinner than traditional pressure switches, these fit in tight, cramped spaces. They’re often built into pumps and hydraulic systems with limited space in order to turn equipment on and off, activate automated controls, or signal alarms when they reach a set pressure. These switches are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They also meet at least one American, Canadian, or European safety standard.
    Quick-Disconnect-Terminal Wire Connection
    Image of Product. Top orientation. Pressure Switches. Compact Pressure Switches, Quick-Disconnect-Terminal Wire Connection.
    External Adjustment—Switches with an external setpoint adjustment have an external ring, so you can set the pressure quickly by hand.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches protect against corrosion.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    1.6 to 2813075±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N110000000
    3 to 481.55075±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N12000000
    4.5 to 962100150±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N13000000
    9.7 to 2405250375±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N14000000
    20 to 48510500750±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N15000000
    100 to 800605,0006,000±5%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N22000000
    500 to 3,0001353,0004,000±6%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    CE Marked
    7799N24000000
    600 to 5,0002905,0006,000±6%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    CE Marked
    7799N26000000
     
    Internal Adjustment
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K81000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K1000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K2000000
     
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K82000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K3000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K83000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K84000000
     

    Economy Pressure Switches

    Use these switches for applications that need reliable switching but don’t require high accuracy. When a set pressure is reached, they turn equipment on and off, signal automatic controls, or trigger alarms. These are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). All meet safety standards.
    Quick-Disconnect-Terminal Wire Connection
    Image of Product. Front orientation. Contains Annotated. Style A. Economy Pressure Switches.
    Style
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    A1 1/2 to 3 1/21.1600750±8%15 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N11000000
    A3 to 403.5600750±3%25 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N1300000
    A30 to 15017.5600750±425 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N1500000
    A100 to 50075600750±5%25 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N1700000
     

    Fixed Setpoint Vacuum Switches

    Image of Product. Front orientation. Vacuum Switches. Fixed Setpoint Vacuum Switches.
    Prevent changes to the set vacuum that powers equipment, activates controls, or signals alarms. The setpoint on these switches isn't adjustable. They’re single pole, double throw (SPDT) and can either turn one circuit from off to on (normally open) or on to off (normally closed).
    NEMA 4 Enclosure Rating—NEMA 4 rated, they seal out dirt, oil, and water from washdowns. All meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components and CE marked.
    NEMA 13 Enclosure Rating—NEMA 13 rated, they seal out dirt, oil, and water from washdowns. All meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components and CE marked.
    Pressure Set
    Point, in. Hg
    Approx. Reset
    Point, in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Quick-Disconnect-Terminal
     
    1/4 NPT Male Pipe Connection
    2817250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N25000000
    2616250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2400000
    2415250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2300000
    2214250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2200000
    2012250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2100000
    1811250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1900000
    1610250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1800000
    149250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1700000
    128250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1600000
    106250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1500000
    85250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1400000
    63250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1300000
    42250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1200000
    21250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1100000
     

    Air-Actuated Hand Switches

    Image of Product. Front orientation. Air-Actuated Switches. Air-Actuated Hand Switches.
    Keep live electrical circuits away from work areas—these switches use air pressure to turn circuits on or off.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Lg.
    Wd.
    Ht.
    Quick-Disconnect
    Tab Wd.
    Includes
    Each
    11 Off or 1 On
    Momentary
    3SPDT
    20 amp @ 125V AC, 250V AC2 1/8"1 3/4"1 1/4"0.187"10 ft. Tubing7695K11000000
    11 Off or 1 On
    Maintained
    3SPDT
    20 amp @ 125V AC, 250V AC2 1/8"1 3/4"1 1/4"0.187"10 ft. Tubing7695K1200000
     
    back to top