    8 Products

    Hazardous-Location Easy-Setup Pressure Transmitters

    Safely monitor liquid, gas, and steam pressure in hazardous locations with these transmitters. They meet NEC safety standards, so they protect against an explosion where flammable gases and vapors are present.
    These transmitters automatically compensate for error created by vibration or fluctuations in temperature, so there’s no need to account for these factors when programming your receiving device. Use the keypad to set the pressure range, choose the unit of measure, and zero the reading. They convert pressure into an electrical signal and send it to your receiving devices, such as remote displays, programmable logic controllers (PLCs), and motor speed controls to monitor pressure or control equipment. Transmitters will only provide accurate readings within the rated pressure range.
    All transmitters are rated IP66 and NEMA 4X to protect against dirt, dust, washdowns, weather, and corrosion, and their Hastelloy nickel connection resists harsh chemicals.
    These transmitters typically connect using two wires to send a 4-20mA output current. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. They can also be configured using three or four wires.
    4 mA to 20 mA Output Current—Screw-Terminal Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Hazardous-Location Easy-Setup Pressure Transmitters.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing
    Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
    HART Communication Protocol
     
    1/2 NPT Male Pipe Connection
    0 to 5514511 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N110000000
    0 to 303058011 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N12000000
    0 to 15015087011 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N13000000
    0 to 4504502,17511 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N14000000
    0 to 1,5001,5002,90011 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N15000000
    0 to 3,0003,00011,60011 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N16000000
    0 to 6,0006,00011,60011 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N17000000
    0 to 10,00010,00016,00011 to 555 1/8"4 3/8"NEC Class I Divisions 1, 2 Groups A, B, C, D
    IP66, NEMA 4X
    CE Marked, CSA Certified
    Air
    Argon
    Hydraulic Fluid
    Nitrogen
    Water
    ±0.075%Aluminum
    Hastelloy Nickel-40 to 1808874N18000000
     