Filter by
Valve Function
System of Measurement
Air Directional Control Valve Flow Pattern
Maximum Pressure @ Temperature
Valve Position
Electrical Connection Type
Connects To
Inlet Connection
Actuation Type
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
Export Control Classification Number (ECCN)
DFARS Specialty Metals
Seat Material
Solenoid Flow-Adjustment Valves
Valves | DIN Plugs | PLCs | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure @ Temp. | Valve Type | Actuation Time, ms | Input Signal | Valve Lg. | Overall Ht. | Enclosure Rating | For Use With | Seal Material | Each | Each | Each | |||||
Brass Body | ||||||||||||||||||||
Fail Closed—24V DC | ||||||||||||||||||||
| 1/2 | Female | NPT | 1.6 | 145 psi @ 190° F | Pressure Drop Assisted, Solenoid | 200 | 24V DC | 1 15/16" | 3 3/8" | IP65 | Water, Oil | Fluoroelastomer | 2675N1 | 0000000 | 2675N11 | 000000 | 2675N12 | 0000000 | ||
| 3/4 | Female | NPT | 5.8 | 145 psi @ 190° F | Pressure Drop Assisted, Solenoid | 200 | 24V DC | 3 1/8" | 5 13/16" | IP65 | Water, Oil | Fluoroelastomer | 2675N2 | 000000 | 2675N11 | 00000 | 2675N12 | 000000 | ||
| 1 | Female | NPT | Not Rated | 145 psi @ 190° F | Pressure Drop Assisted, Solenoid | 200 | 24V DC | 3 1/8" | 5 13/16" | IP65 | Water, Oil | Fluoroelastomer | 2675N3 | 000000 | 2675N11 | 00000 | 2675N12 | 000000 | ||
Compact Solenoid Flow-Adjustment Valves
Thread Size | Gender | Thread Type | Max. Pressure @ Temp. | Valve Type | Min. Pressure Drop Req. | Temp. Range, ° F | Input Signal | Valve Dia. | Overall Ht. | For Use With | Seal Material | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nickel-Plated Brass Body with Wire Leads | |||||||||||||||
Fail Closed—12V DC | |||||||||||||||
| 10-32 | Female | UNF | 100 psi @ 70° F | Zero Pressure Drop, Solenoid | None | 35 to 120 | 0 to 10V DC | 7/8" | 1 9/16" | Air, Argon, Helium, Krypton, Neon, Xenon | Fluoroelastomer | 2555N12 | 0000000 | ||
Fail Closed—24V DC | |||||||||||||||
| 10-32 | Female | UNF | 100 psi @ 70° F | Zero Pressure Drop, Solenoid | None | 35 to 120 | 0 to 20V DC | 7/8" | 1 9/16" | Air, Argon, Helium, Krypton, Neon, Xenon | Fluoroelastomer | 2555N13 | 000000 | ||
Electrically Operated Air Directional Control Valves with Flow Control
Push-to-Connect Male Inlet x Push-to-Connect Male Outlet
Valves | Replacement Solenoids | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | ||||||||||||||||||
No. of Flow Ports | For Tube OD | For Tube ID | For Tube ID | For Tube OD | Exhaust Connection | Max. Flow Rate @ 100 psi, scfm | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | Mounting Fasteners Included | Choose a Voltage | Each | Each | ||||
5/2 Flow Pattern | ||||||||||||||||||||
Single Solenoid—Spring Return | ||||||||||||||||||||
| 5 | 1/4" | 11/64" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 24V DC | 4666A71 | 0000000 | 4666A61 | 0000000 | ||
| 5 | 1/4" | 11/64" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 120V AC | 4666A72 | 000000 | 4666A62 | 000000 | ||
| 5 | 3/8" | 1/4" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 24V DC | 4666A21 | 000000 | 4666A61 | 000000 | ||
| 5 | 3/8" | 1/4" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 120V AC | 4666A22 | 000000 | 4666A62 | 000000 | ||
Double Solenoid—Solenoid Return | ||||||||||||||||||||
| 5 | 1/4" | 11/64" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 24V DC, 120V AC | 4666A5 | 000000 | ——— | 0 | ||
| 5 | 3/8" | 1/4" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 24V DC, 120V AC | 4666A1 | 000000 | ——— | 0 | ||
5/3 (Closed Center) Flow Pattern | ||||||||||||||||||||
Double Solenoid—Solenoid Return | ||||||||||||||||||||
| 5 | 1/4" | 11/64" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 24V DC, 120V AC | 4666A8 | 000000 | ——— | 0 | ||
| 5 | 3/8" | 1/4" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 24V DC, 120V AC | 4666A3 | 000000 | ——— | 0 | ||
5/3 (Pressure Center) Flow Pattern | ||||||||||||||||||||
Double Solenoid—Solenoid Return | ||||||||||||||||||||
| 5 | 1/4" | 11/64" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 24V DC, 120V AC | 4666A9 | 000000 | ——— | 0 | ||
| 5 | 3/8" | 1/4" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20 to 150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 24V DC, 120V AC | 4666A4 | 000000 | ——— | 0 | ||