McMaster-Carr logo
    Filter by
    Valve Function
    System of Measurement
    Pipe Size
    Industrial Info Compare
    Air Directional Control Valve Flow Pattern
    Thread Type
    Industrial Info Compare
    Environment
    Maximum Pressure @ Temperature
    Valve Position
    Vacuum Rating
    Electrical Connection Type
    Number of Solenoids
    Connects To
    Flow Coefficient (Cv)
    Industrial Info Snippet
    Inlet Connection
    Return Actuation
    Actuation Type
    Body Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    19 Products

    Solenoid Flow-Adjustment Valves

    Image of Product. Front orientation. Contains Annotated. Flow-Adjustment Valves. Solenoid Flow-Adjustment Valves.
    Also known as proportional solenoid valves, these adjust and regulate flow based on the intensity of the electrical signal into the valve. All are controlled with PWM signal. Valves are fail closed unless actuated. They require a minimum pressure drop between the inlet and outlet for operation; the upstream pressure must be 7 psi greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves are IP65 rated to resist splashing water and dust. Add a cable plug for DIN connection. To program these valves, use the programmable logic controller (PLC). It has a DIN plug connector and can operate 4-20mA inputs.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    DIN Plugs
    PLCs
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Actuation
    Time, ms
    Input
    Signal
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    For Use
    With
    Seal Material
    Each
    Each
    Each
    Brass Body
     
    Fail Closed—24V DC
    1/2 FemaleNPT
    1.6145 psi @ 190° FPressure Drop Assisted, Solenoid20024V DC1 15/16"3 3/8"IP65
    Water, OilFluoroelastomer
    2675N100000002675N110000002675N120000000
    3/4 FemaleNPT
    5.8145 psi @ 190° FPressure Drop Assisted, Solenoid20024V DC3 1/8"5 13/16"IP65
    Water, OilFluoroelastomer
    2675N20000002675N11000002675N12000000
    1FemaleNPT
    Not Rated145 psi @ 190° FPressure Drop Assisted, Solenoid20024V DC3 1/8"5 13/16"IP65
    Water, OilFluoroelastomer
    2675N30000002675N11000002675N12000000
     

    Compact Solenoid Flow-Adjustment Valves

    Image of Product. Front orientation. Contains Annotated. Flow-Adjustment Valves. Compact Solenoid Flow-Adjustment Valves.
    Available in smaller pipe sizes than other solenoid flow-adjustment valves, these are often used with gas controllers and analytical instrumentation. They adjust and regulate flow based on the intensity of the electrical signal into the valve and are often integrated into PLC systems for automatic control over the valve position based on system conditions. They are fail closed unless actuated. Valves don’t require a pressure drop for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Thread
    Size
    Gender
    Thread
    Type
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Input
    Signal
    Valve
    Dia.
    Overall
    Ht.
    For Use With
    Seal Material
    Each
    Nickel-Plated Brass Body with Wire Leads
     
    Fail Closed—12V DC
    10-32 FemaleUNF
    100 psi @ 70° FZero Pressure Drop, SolenoidNone35 to 1200 to 10V DC7/8"1 9/16"Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer
    2555N120000000
     
    Fail Closed—24V DC
    10-32 FemaleUNF
    100 psi @ 70° FZero Pressure Drop, SolenoidNone35 to 1200 to 20V DC7/8"1 9/16"Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer
    2555N13000000
     

    Electrically Operated Air Directional Control Valves with Flow Control

    Create motion and control the speed of that motion with a single valve. Also known as 4-way valves, these valves create two actions, such as extending and retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion, and adjust the volume of air exiting an air cylinder (meter out) to control speed. Apply voltage to the electrical connection to actuate.
    Push-to-Connect Male Inlet x Push-to-Connect Male Outlet
    Image of Product. Single Solenoid. Front orientation. Single Solenoid. Electrically Operated Air Directional Control Valves with Flow Control.
    Image of Product. Double Solenoid. Front orientation. Double Solenoid. Electrically Operated Air Directional Control Valves with Flow Control.

    Single Solenoid

    Double Solenoid

    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Valves
    Replacement
    Solenoids
    Inlet
    Outlet
    Overall
    No. of Flow
    Ports
    For Tube
    OD
    For Tube
    ID
    For Tube
    ID
    For Tube
    OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Choose a
    Voltage
    Each
    Each
    5/2 Flow Pattern
     
    Single Solenoid—Spring Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No24V DC4666A7100000004666A610000000
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No120V AC4666A720000004666A62000000
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No24V DC4666A210000004666A61000000
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No120V AC4666A220000004666A62000000
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A5000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A1000000———0
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A8000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A3000000———0
     
    5/3 (Pressure Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A9000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A4000000———0
     
    back to top