    Compact Solenoid Flow-Adjustment Valves

    Image of Product. Front orientation. Contains Annotated. Flow-Adjustment Valves. Compact Solenoid Flow-Adjustment Valves.
    Available in smaller pipe sizes than other solenoid flow-adjustment valves, these are often used with gas controllers and analytical instrumentation. They adjust and regulate flow based on the intensity of the electrical signal into the valve and are often integrated into PLC systems for automatic control over the valve position based on system conditions. They are fail closed unless actuated. Valves don’t require a pressure drop for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Thread
    Size
    Gender
    Thread
    Type
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Input
    Signal
    Valve
    Dia.
    Overall
    Ht.
    For Use With
    Seal Material
    Each
    Nickel-Plated Brass Body with Wire Leads
     
    Fail Closed—12V DC
    10-32 FemaleUNF
    100 psi @ 70° FZero Pressure Drop, SolenoidNone35 to 1200 to 10V DC7/8"1 9/16"Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer
    0000000000000
     
    Fail Closed—24V DC
    10-32 FemaleUNF
    100 psi @ 70° FZero Pressure Drop, SolenoidNone35 to 1200 to 20V DC7/8"1 9/16"Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer
    000000000000
     

    Motor-Driven Flow-Adjustment Valves

    Image of Product. Assembled View. Front orientation. Contains Annotated. Flow-Adjustment Valves. Motor-Driven Flow-Adjustment Valves.
    Image of Product. Exploded View. Front orientation. Exploded view. Flow-Adjustment Valves. Motor-Driven Flow-Adjustment Valves.

    Assembled View

    Exploded View

    Also known as proportional V-ball valves, these have a motor that adjusts and regulates flow in applications with higher flow rates and pressures than solenoid valves. As you increase the intensity of the electrical signal, the motor opens the valve, moving a ball with a V-cut opening that proportionately allows more flow as the valve opens. They're often integrated into PLC systems for automatic control over the valve position based on system conditions. Valves can accept both 4-20 mA current and 0-10 DC voltage. All are fail open unless actuated. They don't require a minimum pressure drop between the inlet and outlet for operation. All are full port, so they do not restrict flow.
    The three-piece bolted body comes apart for access to internal components without unthreading pipe connections and removing the valve from your line. It is 316 stainless steel for excellent corrosion resistance. The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. A manual override allows you to operate the valve during power outages.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Overall
    Pipe
    Size
    Gender
    Thread
    Type
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Actuation
    Time, sec.
    Input Signal
    Valve
    Lg.
    Ht.
    Lg.
    Enclosure
    Rating
    For Use With
    Seal Material
    Certification
    Flow Coefficient
    (Cv)
    Each
    316 Stainless Steel Body with Screw Terminals
     
    Fail Open—100V AC to 240V AC
    1FemaleNPT
    1,000 psi @ 100° FZero Pressure Drop, BallNone0 to 40084 to 20 mA, 0 to 10V DC3 5/8"10 3/4"7 3/8"NEMA 4X
    Water, Oil, Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer/PTFE PlasticCSA Certified, UL Listed
    220000000000000000
    1 1/2 FemaleNPT
    1,000 psi @ 100° FZero Pressure Drop, BallNone0 to 40094 to 20 mA, 0 to 10V DC4 9/16"12 9/16"7 3/4"NEMA 4X
    Water, Oil, Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer/PTFE PlasticCSA Certified, UL Listed
    57000000000000000
    2 FemaleNPT
    1,000 psi @ 100° FZero Pressure Drop, BallNone0 to 40094 to 20 mA, 0 to 10V DC5 3/8"12 15/16"7 3/4"NEMA 4X
    Water, Oil, Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer/PTFE PlasticCSA Certified, UL Listed
    89000000000000000
    3 FemaleNPT
    350 psi @ 100° FZero Pressure Drop, BallNone0 to 400274 to 20 mA, 0 to 10V DC7 1/16"15 1/2"10 1/2"NEMA 4X
    Water, Oil, Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer/PTFE PlasticCSA Certified, UL Listed
    227000000000000000
     

    Solenoid Flow-Adjustment Valves

    Image of Product. Front orientation. Flow-Adjustment Valves. Solenoid Flow-Adjustment Valves.
    Also known as proportional solenoid valves, these adjust and regulate flow based on the intensity of the electrical signal into the valve. All are controlled with PWM signal. Valves are fail closed unless actuated. They require a minimum pressure drop between the inlet and outlet for operation; the upstream pressure must be 7 psi greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves are IP65 rated to resist splashing water and dust. Add a cable plug for DIN connection. To program these valves, use the programmable logic controller (PLC). It has a DIN plug connector and can operate 4-20mA inputs.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Flow-Adjustment Valves
    DIN Plugs
    Programmable
    Logic Controllers
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Actuation
    Time, sec.
    Input Signal
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    For Use
    With
    Seal Material
    Each
    Each
    Each
    Brass Body
     
    Fail Closed—24V DC
    1/2 FemaleNPT
    1.6145 psi @ 190° FPressure Drop Assisted, Solenoid10333 mA, 24V DC1 15/16"3 3/8"IP65
    Water, OilFluoroelastomer
    0000000000000000000000000000000000000000
    3/4 FemaleNPT
    5.8145 psi @ 190° FPressure Drop Assisted, Solenoid10667 mA, 24V DC3 1/8"5 13/16"IP65
    Water, OilFluoroelastomer
    0000000000000000000000000000000000000
    1FemaleNPT
    Not Rated145 psi @ 190° FPressure Drop Assisted, Solenoid10667 mA, 24V DC3 1/8"5 13/16"IP65
    Water, OilFluoroelastomer
    0000000000000000000000000000000000000
     