About Process Pumps
More
How to Determine Feet of Head
More
How to Prime Your Pump
More
About Vacuum Pumps
More
About Sump, Water-Removal, Condensate, and Submersible Pumps
More
Adjustable-Flow Inline Circulation Pumps for Water

Accommodate performance changes in your system with a three-speed switch that adjusts flow rate. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Mount horizontally with the included pipe connectors. Do not run dry or use with solids. Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps with 304 stainless steel housing are lead free.
Flow Rate, gpm (Speed No.) | Pipe Size (Female, NPT) | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. | @ 10 ft. of Head | @ 20 ft. of Head | Current, A (Speed No.) | Flow Adjustment Rate | Max. ft. of Head | Max. Viscosity, cP | hp | Intake | Discharge | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||
Cast Iron Housing—Hardwire | ||||||||||||||
6 (1), 11 (2), 18 (3) | 2 (1), 6 (2), 11 (3) | 1 (2), 3 (3) | 0.7 (1), 0.8 (2), 1 (3) | ± 10% | 24 | 1 | 1/6 | 1 | 1 | 6" | 5" | 6 3/8" | 00000000 | 0000000 |
6 (1), 11 (2), 18 (3) | 2 (1), 6 (2), 11 (3) | 1 (2), 3 (3) | 0.7 (1), 0.8 (2), 1 (3) | ± 10% | 24 | 1 | 1/6 | 1 1/4 | 1 1/4 | 6" | 5" | 6 3/8" | 00000000 | 000000 |
6 (1), 11 (2), 18 (3) | 2 (1), 6 (2), 11 (3) | 1 (2), 3 (3) | 0.7 (1), 0.8 (2), 1 (3) | ± 10% | 24 | 1 | 1/6 | 1 1/2 | 1 1/2 | 6" | 5" | 6 3/8" | 00000000 | 000000 |
304 Stainless Steel Housing—Hardwire | ||||||||||||||
6 (1), 11 (2), 18 (3) | 2 (1), 6 (2), 11 (3) | 1 (2), 3 (3) | 0.7 (1), 0.8 (2), 1 (3) | ± 10% | 24 | 1 | 1/6 | 1 | 1 | 6" | 5" | 6 3/8" | 00000000 | 000000 |
6 (1), 11 (2), 18 (3) | 2 (1), 6 (2), 11 (3) | 1 (2), 3 (3) | 0.7 (1), 0.8 (2), 1 (3) | ± 10% | 24 | 1 | 1/6 | 1 1/4 | 1 1/4 | 6" | 5" | 6 3/8" | 00000000 | 000000 |
6 (1), 11 (2), 18 (3) | 2 (1), 6 (2), 11 (3) | 1 (2), 3 (3) | 0.7 (1), 0.8 (2), 1 (3) | ± 10% | 24 | 1 | 1/6 | 1 1/2 | 1 1/2 | 6" | 5" | 6 3/8" | 00000000 | 000000 |
Compact Inline Circulation Pumps for Water

Use these pumps in pipelines with limited clearance. Install directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Pumps mount horizontally or vertically with required pipe connectors. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake | Discharge | Overall | Mounting | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | No. of Holes | Hole Dia. | Each | |
120V AC, Single Phase | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 2 | 3/4 | Female | NPT | 3/4 | Female | NPT | 7 3/4" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 0000000 |
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 2 | 1 | Female | NPT | 1 | Female | NPT | 7 3/4" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 2 | 1 1/4 | Female | NPT | 1 1/4 | Female | NPT | 7 3/4" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 2 | 1 1/2 | Female | NPT | 1 1/2 | Female | NPT | 7 3/4" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
240V AC, Single Phase | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 1.06 | 3/4 | Female | NPT | 3/4 | Female | NPT | 7 1/2" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 1.06 | 1 | Female | NPT | 1 | Female | NPT | 7 1/2" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 1.06 | 1 1/4 | Female | NPT | 1 1/4 | Female | NPT | 7 1/2" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
34 | 26 | 17 | 5 | 34 | 1 | 1/6 | 1.06 | 1 1/2 | Female | NPT | 1 1/2 | Female | NPT | 7 1/2" | 6 1/2" | 6" | 2 | 1/2" | 00000000 | 000000 |
Easy-Maintenance Inline Circulation Pumps for Water

A detachable motor assembly allows you to leave these pumps inline while servicing or repairing the motor. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically with the included pipe connectors. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ 10 ft. of Head, gpm | Max. ft. of Head | Max. Temp., °F | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
75 | 22 | 10 | 225° | 1 | 1/6 | 1.9 | 1 | Female | NPT | 1 | Female | NPT | 15 3/8" | 5 1/4" | 8 1/2" | 0000000 | 000000000 |
75 | 22 | 10 | 225° | 1 | 1/6 | 1.9 | 1 1/4 | Female | NPT | 1 1/4 | Female | NPT | 15 3/8" | 5 1/4" | 8 1/2" | 0000000 | 00000000 |
75 | 22 | 10 | 225° | 1 | 1/6 | 1.9 | 1 1/2 | Female | NPT | 1 1/2 | Female | NPT | 15 3/8" | 5 1/4" | 8 1/2" | 0000000 | 00000000 |
Easy-Carry Water-Removal Pumps without Switch

These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||
23 | 20 | 14 | 9 | 26 | 1/8" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 6" | 4.3" | 00000000 | 0000000 |
Plug with 25 ft. Cord | ||||||||||||||||
18 | 17 | 14 | 9 | 26.3 | 1/8" | 35° to 120° | 1/6 hp | 5 | 1 | NPT | Female | 8" | 7" | 5" | 00000000 | 000000 |
Long-Life Easy-Carry Water-Removal Pumps

The switch activates on increasing pressure caused by rising water levels for a long service life. It has a separate cord, so you can replace the switch without replacing the whole pump. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||
23 | 19 | 8 | 26 | 1/8" | 9" | 4" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 0000000 |
Plug with 18 ft. Cord | |||||||||||||||||
23 | 19 | 8 | 26 | 1/8" | 3" | 1 1/2" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 000000 |
Oil-Free Electric Vacuum Pumps

Generate a vacuum with no risk of oil contamination in your system. These pumps can also create compressed air for powering tools and controlling fluid motion. In vacuum generation, the maximum flow rate is the rate at which air is pumped before a vacuum is created. Flow rate steadily decreases as the pump generates the vacuum. The larger the tank, the longer it will take to form a vacuum.
Style A pumps withstand harsh operating conditions. Use them to service machinery, refrigeration systems, and circulation systems. As compressors, they can power pneumatic tools.
Threaded connections are secure and leak resistant. They’re ideal for permanent or semi-permanent installations.

Intake | Discharge | O'all | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Max. Vacuum, in. of Hg | Max. Flow Rate, cfm | Max. Pressure, psi | Temp. Range, °F | Volume, dBA | Horsepower | Current, A | Connection Style | Pipe Size | Thread Type | Gender | Connection Style | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
NEMA 5-15 Plug | ||||||||||||||||||||
A | 27.5 | 1.75 | 50 | 35° to 100° | 70 | 1/6 hp | 3.5 | Threaded | 1/4 | NPT | Female | Threaded | 1/4 | NPT | Female | 11 1/2" | 5 5/8" | 8 5/8" | 000000 | 0000000 |