    High-Head Circulation Pumps for Water

    Also known as booster pumps, these have a multistage impeller that propels water about two times higher and farther than standard circulation pumps. Use them in applications such as water delivery, irrigation, and pressure washing. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    208V AC to 240V AC/440V AC to 480V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water.
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 130 ft.
    of Head
    @ 140 ft.
    of Head
    @ 150 ft.
    of Head
    @ 200 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Hardwire—50 cP Maximum Viscosity
    222222211525423237.7 amp to 8.2 amp/3.7 amp to 4 amp1 Female NPT1 Female NPT17 1/4"6 1/4"7 1/2"8134K34000000000
     

    Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Stainless Steel Circulation Pumps for Chemicals.
    A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire
    1309555791003/16"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K940000000004320K190000000
    1408555881003/32"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K93000000004320K18000000
     
    Repair Kits

    High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Image of Product. Front orientation. Centrifugal Pumps. High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Propel liquid higher and farther than standard high-efficiency circulation pumps. These pumps use less electricity to achieve the same flow rates as other circulation pumps. They have a totally enclosed fan cooled (TEFC) motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    @ 120 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—17 cP Maximum Viscosity
    80705847137150025037.4 amp to 7.9 amp/3.7 amp1 1/2 Female NPT1 1/4 Female NPT18"10"9 7/8"Canada8256K44000000000
     

    High-Flow Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Inline Circulation Pumps for Water.
    A high-horsepower motor handles four times the flow and twice the pressure of other inline circulation pumps. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Required Pipe
    Connectors
    Flow
    Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Pair
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    240188135481453528037.7 amp to 8.4 amp/3.9 amp3 Female NPT3 Female NPT8 3/8"19"24 1/8"8115K340000000008115K620000000
     

    High-Flow Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Harsh Environment Self-Priming Circulation Pumps for Water and Coolants.
    A powerful motor provides twice the flow rate of other self-priming circulation pumps. It is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    375165130756512540180310 amp/5 amp3 Female NPT3 Female NPT26 5/8"12"11 7/8"99435K3700000000099435K360000000
     

    Extended-Life Plastic Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Plastic Circulation Pumps for Chemicals.
    These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Pipe
    Size (Gender)
    Discharge Pipe
    Size (Gender)
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    1201201201201121059295537.8 amp to 8 amp/3.9 amp2 (Male)1 1/2 (Male)24 3/8"11 1/2"10 1/2"3068N260000000003068N2520000000003068N251000000
     

    High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Use less electricity to achieve the same flow rates as other circulation pumps. These pumps have a totally enclosed motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Cannot Be Sold To—Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
    Pumps
    Impellers
    Flow
    Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    Each
    Hardwire
    15512585581001737.2 amp to 7.9 amp/3.6 amp2 Female NPT1 1/2 Female NPT17"10 1/2"8"Canada9923K470000000004320K490000000
     

    Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps for Water and Coolants.
    Drain underground tanks and process wastewater with pumps that can be installed up to 20 ft. above your liquid source. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    1621201008087754018039 amp/5 amp2 Female NPT2 Female NPT20 3/8"7 1/2"11 1/8"99435K7300000004320K230000000
     

    Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Harsh Environment Self-Priming Circulation Pumps for Water and Coolants.
    The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    1208270581007540180316 amp1 1/2 Female NPT1 1/2 Female NPT19 1/2"9 1/8"10"99435K64000000099435K641000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    120827058100754018038 amp/4 amp1 1/2 Female NPT1 1/2 Female NPT19"9 1/8"10"99435K6500000099435K65100000
    15076604382754018038 amp/4 amp2 Female NPT2 Female NPT20 3/8"9 1/8"11 1/8"99435K720000000099435K72100000
     

    Constant-Flow-Rate Gear Pumps for Water

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Water.
    These gear pumps produce a smooth flow of liquid for applications such as cooling engines, powering hydraulic equipment, and extracting liquid from holding tanks. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. Do not use with solids. Pumps can be used in dusty, dirty, and damp environments.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold to Canada—Pumps that cannot be sold to Canada are restricted by local energy efficiency requirements.
    Intake
    (NPT)
    Discharge
    (NPT)
    Overall
    Max. Flow
    Rate, gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Gender
    Pipe
    Size
    Gender
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    230V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    23150100,00032 to 14038.4 amp/4.2 amp1
    Female1
    FemaleTotally Enclosed Fan-Cooled (TEFC)25 1/8"10 5/16"9 1/16"Canada4272K23000000000
     

    Circulation Pumps for Fuel and Flammable Liquid

    Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Fuel and Flammable Liquid.
    Pumps
    Impellers
    Flow
    Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    208V AC to 240V AC/460V AC, Three Phase—Hardwire
    140120477515026437.6 amp to 8.1 amp/3.8 amp2 Female NPT1 1/2 Female NPT17 1/8"11 7/8"8 1/2"8205K480000000008205K4610000000
     
    Repair Kits

    Flanged Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Flanged Peristaltic Pumps for Chemicals.
    Commonly used in mining, wastewater treatment, and other systems that require large-diameter hose, these pumps have flanged hose connections. They are compatible with chemicals such as cleaning fluids, acid-washing solutions, and detergents. Pumps have a reverse switch that allows flow in either direction. They are self-priming and create suction to draw liquid upward. They can run dry.
    Bolt
    Overall
    Flow Rate,
    gpm
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current, amp
    Intake
    Connection
    Discharge
    Connection
    Flange
    OD
    Circle
    Dia.
    No. of
    Holes
    Hole
    Size
    Lg.
    Wd.
    Ht.
    Each
    240V AC/460V AC, Three Phase
     
    Hardwire
    621722,0000 to 17533.9/7.8FlangedFlanged4 1/4"3 1/8"40.62"26 3/16"16 5/8"16 7/8"2928N332000000000
     

    Constant-Flow-Rate Gear Pumps for Oil

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Oil.
    A high-horsepower motor moves oil with a viscosity similar to SAE 60 motor oil. These gear pumps produce a smooth flow of liquid to lubricate equipment and blend oils. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold Outside North America—Products cannot be sold outside North America due to restrictions.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    30 gpm577250880-20 to 24038.2 amp/4.1 amp1
    ThreadedFemale1
    ThreadedFemale25"6 7/8"8 1/2"Outside North America41505K47000000000
     

    Circulation Pumps for Hot Oil

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Hot Oil.
    Transfer hot oil up to 650° F in demanding applications such as plastic mold injecting and chemical processing. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.
    Overall
    Max. Flow
    Rate, gpm
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.,
    ° F
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—32 cP Maximum Viscosity
    86756554128150Not Rated65037.6 amp/3.8 amp1 1/2 Female NPT1 1/4 Female NPT22"9"10"California, Canada1020N14000000000
     

    Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units.
    Create and supply hydraulic pressure. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation. An inlet filter protects the pump from contamination.
    All units include an additional NPTF threaded inlet port. NPTF (Dryseal) threads are compatible with NPT threads. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Overall
    Inlet Connection —
    UN/UNF (SAE Straight)
    Inlet
    Connection — NPTF
    Outlet Connection —
    UN/UNF (SAE Straight)
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Thread
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Thread
    Size
    Dash Size
    Full Load Current
    @ Voltage
    Each
    240V AC/460V AC, Three Phase
    2.71,75031017 3/8"19"32 1/2"1 1/16"-12
    123/4
    121 1/16"-12
    124.4 amp @ 460V AC62915K33000000000
     

    Portable Electric Air Compressors

    Image of Product. Front orientation. Air Compressors. Portable Electric Air Compressors, Style B.
    Image of Product. Front orientation. Air Compressors. Portable Electric Air Compressors, Style C.

    Style B

    Style C

    Power drills, wrenches, and saws around your facility. Compact and lightweight compared to other air compressors, these air compressors come with handles or wheels, so you can move and store them out of the way when not in use. Because they’re single stage, these compressors are best for infrequent use. They turn on when tank pressure drops to the actuation point and shut off when it reaches maximum pressure.
    Choose a compressor with a tank size that matches your application. The larger the tank, the more tools it can power. A greater reserve of air means the compressor can run less often, which keeps it cool and improves energy efficiency for a longer life.
    Continuous Duty—Compressors for continuous duty can run without a cooling period. They’re designed for applications that require a constant supply of compressed air.
    Intermittent Duty—Compressors for intermittent duty require a cooling period between uses so they don’t overheat.
    Cannot Be Sold To—Compressors that cannot be sold to the listed areas are restricted due to product regulations.
    Oil—Pair air compressors with the listed oil (sold separately) to extend their service life.
    Air Compressors
    Oil
    Replacement
    Filter Elements
    Pressure,
    psi
    Overall
    Outlet
    Style
    Max.
    Actuation
    Max. Flow Rate
    @ Pressure
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Pipe
    Size
    Thread
    Type
    Gender
    No. of
    Handles
    No. of
    Wheels
    Wt.,
    lb.
    Cannot Be Sold To
    Each
    Container
    Size
    Cannot Be Sold To
    Each
    Each
    Intermittent Duty (30 Minutes On, 30 Minutes Off)
     
    Single Phase, 120V AC
    B1401106.5 ft³/min @ 90 psi5.2313.88419 1/2"19"29"1/4
    NPT
    Female2288Outside United States9965K6400000009.6 oz.Outside United States9965K113000000———0
     
    Continuous Duty
     
    Single Phase, 240V AC
    C13510511.3 ft³/min @ 90 psi8314.77842"18"25"1/4
    NPT
    Female211754309K27000000000.5 L4309K14000004309K13000000
     
    Replacement V-Belts

    Light Duty Electric Air Compressors

    Image of Product. Front orientation. Air Compressors. Light Duty Electric Air Compressors.
    Pressurize air to power drills, wrenches, and grinders. Because they’re single-stage, these compressors are best for infrequent use. They turn on when tank pressure drops to the actuation point and shut off when it reaches maximum pressure. Hardwire them to your power source. Choose a compressor with a tank size that matches your application. The larger the tank, the more tools it can power. A greater reserve of air means the compressor can run less often, which keeps it cool and improves energy efficiency for a longer life.
    Continuous Duty—Compressors for continuous duty can run without a cooling period. They’re designed for applications that require a constant supply of compressed air.
    Oil—Pair air compressors with the listed oil (sold separately) to extend their service life.
    Air Compressors
    Oil
    Replacement
    Filter Elements
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate
    @ Pressure
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Mounting
    Position
    Certification
    Each
    Container
    Size, L
    Each
    Each
    Continuous Duty
     
    Single Phase, 230V AC
    13510511.3 ft³/min @ 90 psi60314.7851/2
    NPT
    Female25"24"67"VerticalCSA Certified
    8298N150000000000.54309K140000004309K13000000
     