About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Drum Pumps
More
Hazardous Location High-Flow Battery-Operated
Drum Pumps with Nozzle for Fuel

These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. They have an automatic shut-off nozzle so they turn off when the tank is full. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | ID | Lg., ft. | Nozzle Type | Max. Shackle Dia. | Thermal Protection | Each | |
12V DC | |||||||||||||||||||
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Automatic Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000000 |
High-Flow Sump Pumps for Sewage Water with Replaceable Float Switch
These pumps provide about 25% more flow than standard float-switch activated pumps for sewage water. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Pumps are equipped with a large intake and rugged impeller to transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Pumps can run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
120 | 96 | 65 | 26 | 2" | 13" | 6" | 35° to 75° | 2/5 hp | 12 | Open | 2 | NPT | Female | 24" | 30" | 17" | 8" | 11" | 0000000 | 0000000 |
Sump Pumps without Float Switch for Sewage Water

Pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
Float-Switch Activated Sump Pumps for Sewage Water

Equipped with a large intake and a rugged impeller, this pump transfers raw sewage water with solids up to 2" in diameter. It has a cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 13" | 8" | 35° to 140° | 4/10 hp | 8 | Open | 2 | NPT | Female | 18" | 30" | 14 1/2" | 11" | 9" | 00000000 | 0000000 |
Sump Pumps for Sewage Water with Replaceable Float Switch

The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 19" | 11" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
Sump Pumps with Basin for Sewage Water

Convenient for applications where a sump pit is impractical, these pumps include a basin with a vent on top. They handle raw sewage water with solids up to 2" in diameter. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
Max. Flow Rate, gpm | Level | Discharge | O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Feet of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Cap., gal. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||||
125 | 100 | 65 | 20 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 2/5 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 0000000 |
Sump Pumps for Water with Small Solids with Replaceable Float Switch

The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as effluent pumps, these accommodate solids up to 3/4" in diameter. They’re often used with liquid waste that has passed through a septic tank, so most solids are removed. All have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
70 | 65 | 50 | 26 | 40 | 3/4" | 12" | 6" | 35° to 140° | 2/5 hp | 7.5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 8" | 00000000 | 0000000 |
High-Flow Sump Pumps without Switch for Water with Small Solids

Use these pumps to move higher volumes of water with solids than other sump pumps. They activate when plugged in; add a plug-in switch to control when the pump activates. Also known as effluent pumps, they accommodate solids up to 3/4" in diameter. They are often used with liquid waste that has passed through a septic tank, so most solids are removed. Pumps have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||
70 | 65 | 50 | 26 | 40 | 3/4" | 35° to 140° | 2/5 hp | 7.5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 8" | 00000000 | 0000000 |
Sump Pumps with Basin for Water with Small Solids
Convenient for applications where a sump pit is impractical, this pump includes a basin with a vent on top. It has a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as an effluent pump, it accommodates solids up to 3/4" in diameter. It is often used with liquid waste that has passed through a septic tank, so most solids are removed.

Max. Flow Rate | Level | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Capacity, gal. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Pipe Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
70 | 65 | 50 | 26 | 40 | 3/4" | 10" | 5" | 5 | 35° to 125° | 2/5 hp | 7.5 | 1 1/2 | Female | 1 1/2 | Female | 16" | 15" | 15" | 0000000 | 0000000 |
Water Removal Pumps with Hose

Use this pump to remove water with small solids up to 1/4" in diameter. It activates when plugged in; add a plug-in switch to control when the pump activates. Install in water that's at least 2" deep. Pump includes a 25-ft. hose with cam-and-groove fittings for quick, secure connections and a storage crate with built-in filtration to protect the pump from debris.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Connection Coupling Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug with 15" Cord | |||||||||||||||||
41 | 32 | 23 | 11 | 41 gpm | 25 | 1/4" | 7/16" | 35° to 100° | 4/10 hp | 3 | 1 1/4 | Male | 12 3/4" | 11 13/16" | 15 3/4" | 0000000 | 0000000 |