    18 Products

    High-Flow Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Harsh Environment Self-Priming Circulation Pumps for Water and Coolants.
    A powerful motor provides twice the flow rate of other self-priming circulation pumps. It is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    375265225200160110125401807 1/220 amp/10 amp3 Female NPT3 Female NPT26 5/8"12"11 7/8"99435K4100000000099435K4110000000
     

    High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Use less electricity to achieve the same flow rates as other circulation pumps. These pumps have a totally enclosed motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Cannot Be Sold To—Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
    Pumps
    Impellers
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 70 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    Each
    Hardwire
    26021076100177 1/216.8 amp to 18.5 amp/8.4 amp2 1/2 Female NPT2 Female NPT23"12"11"Canada9923K490000000004320K540000000
     

    Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units.
    Create and supply hydraulic pressure. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation. An inlet filter protects the pump from contamination.
    All units include an additional NPTF threaded inlet port. NPTF (Dryseal) threads are compatible with NPT threads. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Overall
    Inlet Connection —
    UN/UNF (SAE Straight)
    Inlet
    Connection — NPTF
    Outlet Connection —
    UN/UNF (SAE Straight)
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Thread
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Thread
    Size
    Dash Size
    Full Load Current
    @ Voltage
    Each
    240V AC/460V AC, Three Phase
    6.31,8007 1/22021 3/8"22 1/2"37 3/8"1 1/16"-12
    123/4
    121 1/16"-12
    129.5 amp @ 460V AC62915K36000000000
     

    Electric Air Compressors

    Image of Product. Vertical. Front orientation. Air Compressors. Electric Air Compressors.
    Image of Product. Horizontal. Front orientation. Air Compressors. Electric Air Compressors.

    Vertical

    Horizontal

    From lifting heavy objects to mixing large vats, these compressors power the equipment that keeps your production line going. They use pistons to compress air in two stages to generate higher pressures and flow rates than single-stage compressors. This two-step process—compressing air, cooling it, and compressing it again—prevents heat and reduces wear, so you can run them continuously.
    When choosing a tank size, keep in mind a larger tank capacity means you won't have to run them continuously, which extends their life. These compressors turn on when tank pressure drops to the actuation point and shut off when it reaches maximum pressure.
    If you plan to run them continuously, use SAE 20 synthetic oil (sold separately) to maintain performance and efficiency.
    Air Compressors
    Oil
    Replacement
    Filter Elements
    Replacement
    V-Belts
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate @ Pressure
    Mounting
    Position
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Container
    Size, qt.
    Each
    Each
    Each
    Continuous Duty
     
    Single Phase, 230V AC
    17513523.6 ft³/min @ 175 psi
    24.3 ft³/min @ 100 psi
    Vertical807 1/228.6793/4
    NPT
    Female35"28"77"Lubricant
    Tank Pressure Gauge
    41905K300000000014364K760000004364K750000004364K72000000
     
    Three Phase, 230V AC
    17513523.6 ft³/min @ 175 psi
    24.3 ft³/min @ 100 psi
    Vertical807 1/219.6793/4
    NPT
    Female35"28"77"Lubricant
    Tank Pressure Gauge
    41905K420000000014364K76000004364K75000004364K7200000
     
    Three Phase, 460V AC
    17513523.6 ft³/min @ 175 psi
    24.3 ft³/min @ 100 psi
    Vertical807 1/211793/4
    NPT
    Female35"28"77"Lubricant
    Tank Pressure Gauge
    41905K430000000014364K76000004364K75000004364K7200000
     

    Electric Air Compressors with Aftercooler

    Image of Product. Front orientation. Air Compressors. Electric Air Compressors with Aftercooler.
    Power equipment with built-in moisture control—these air compressors have a built-in aftercooler that cools down air leaving the compressor to remove condensation. This helps relieve the strain on your separator and dryer down the line. These compressors are useful for air-powered tools, where corrosion can clog air lines, and for control systems, where moisture can disrupt signals.
    These compressors use pistons to pressurize air in two stages—compressing air, cooling it, and then compressing it again. This two-step process reduces wear, limits heat buildup, and improves overall efficiency. The integrated aftercooler cools the air as it exits the compressor, condensing any remaining moisture so it can be drained before it causes an issue. The automatic drain clears the condensate from the tank to keep everything running smoothly—especially important in high-moisture lines.
    These compressors turn on when tank pressure drops to the actuation point and shut off when it reaches maximum pressure. They can run continuously without a cooling period. If you plan to run them continuously, use SAE 30 synthetic oil (sold separately) to maintain performance and efficiency.
    Air Compressors
    Oil
    Replacement
    Filter Elements
    Replacement
    V-Belts
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate @ Pressure
    Mounting
    Position
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load
    Current, amp
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Container
    Size, qt.
    Each
    Each
    Each
    Continuous Duty
     
    Single Phase, 230V AC
    17513523.6 ft³/min @ 175 psi
    24.3 ft³/min @ 100 psi
    Vertical807 1/228.6783/4
    NPT
    Female35"28"77"Aftercooler
    Lubricant
    Shutdown Switch
    Tank Pressure Gauge
    8233N11100000000014364K760000004364K750000004364K72000000
     
    Three Phase, 230V AC
    17513523.6 ft³/min @ 175 psi
    24.3 ft³/min @ 100 psi
    Vertical807 1/219.6783/4
    NPT
    Female35"28"77"Aftercooler
    Lubricant
    Shutdown Switch
    Tank Pressure Gauge
    8233N1120000000014364K76000004364K75000004364K7200000
     
    Three Phase, 460V AC
    17513523.6 ft³/min @ 175 psi
    24.3 ft³/min @ 100 psi
    Vertical807 1/29.8783/4
    NPT
    Female35"28"77"Aftercooler
    Lubricant
    Shutdown Switch
    Tank Pressure Gauge
    8233N1130000000014364K76000004364K75000004364K7200000
     

    Low-Noise Electric Air Compressors

    Image of Product. Front orientation. Air Compressors. Low-Noise Electric Air Compressors.
    As quiet as an idling forklift, these rotary screw compressors make less noise than traditional piston compressors but deliver the same power. They turn on when tank pressure drops to the actuation point and off when it reaches the maximum. Use them for manufacturing, processing, and packaging jobs where steady output matters—you can run them continuously. If you plan to run them continuously, use SAE 20 synthetic oil (sold separately) to maintain performance and efficiency.
    Air Compressors
    Oil
    Replacement
    Filter Elements
    Pressure,
    psi
    Outlet
    Overall
    Max.
    Actuation
    Max. Flow Rate
    @ Pressure
    Mounting
    Position
    Tank Cap.,
    gal.
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Container
    Size, gal.
    Each
    Each
    Continuous Duty
     
    Single Phase, 230V AC
    13811525.2 ft³/min @ 138 psiHorizontal607 1/235 amp @ 230V AC641/2
    NPT
    Female58"26"50"Lubricant
    Tank Pressure Gauge
    8277N1300000000018277N1500000008277N16000000
     
    Three Phase, 208/230/460V AC
    13811525.2 ft³/min @ 138 psiHorizontal607 1/226 amp @ 208V AC
    23.5 amp @ 230V AC
    12 amp @ 460V AC
    641/2
    NPT
    Female58"26"50"Lubricant
    Tank Pressure Gauge
    8277N140000000018277N150000008277N1600000
     