    41 Products
    About Electrical Switches
    industrial info icon

    Choose a switch with the right trigger type, number of inputs, and control functions to power your equipment.

    Outlet-Box-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Outlet-Box-Mount Push-Button-Actuator Emergency Stop Switches.
    Immediately cut power with a single push. The large palm-sized buttons on these switches provide an easy target, so they're easy to use even while wearing gloves. When the button is depressed, the switch latches and can be locked in that position using a lockout or padlock with a 9/32” shackle diameter (not included). All have positive force contacts that will open the circuit when actuated even if a spring fails or the contacts stick. They're rated NEMA 13 and IP65 for protection from oil/coolant spraying and washdowns.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Cover
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Enclosure
    Rating
    Specs. Met
    Certification
    Each
    Plastic Actuator with Screw-Terminal Wire Connection
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    RedYellow6 amp @ 120V AC
    2.2 amp @ 125V DC
    600V AC
    250V DC
    2 1/4"IP65
    NEMA 13
    EN 60947-5-5, IEC 60947-5-5, UL 508CE Marked
    CSA Certified
    CSA-US Certified
    UL Listed
    66185K610000000
     

    30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Immediately cut power with a single push. These switches are rated for protection from low-pressure streams of water and oil/coolant spraying. They have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. Mount them in a standard panel cutout.
    Metal Actuator Base with Screw-Terminal Wire Connection—Not Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Pull Reset.
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Twist Reset.

    Pull Reset

    Twist Reset

    Pull Reset—Turn pull switches back on by pulling the button.
    Twist Reset—Turn twist switches back on by twisting the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Each
    Pull Reset
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K3450000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K346000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K347000000
     
    Twist Reset
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K338000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K339000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K341000000
     
    Accessories and Replacements for Emergency Stop Switches
    Metal Actuator Base with Screw-Terminal Wire Connection and Lockout—Not Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Lockout, Pull Reset.

    Pull Reset

    Switches with lockout latch when you depress the button and can be locked in that position using a lockout or padlock with a 9/32" shackle diameter.
    Pull Reset—Turn pull switches back on by pulling the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Each
    Pull Reset
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.2 amp @ 125V DC
    600V AC
    150V DC
    2"61 7/8"66185K710000000
     
    Blocks
    Metal Actuator Base with Screw-Terminal Wire Connection—Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Illuminated, Pull Reset.

    Pull Reset

    Illuminated switches are visible in low light. They include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    Pull Reset—Turn pull switches back on by pulling the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Choose a Bulb Voltage
    Each
    Pull Reset
    11 Off
    Maintained
    4SPST-NO
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 1/16"24V AC/24V DC, 120V AC/120V DC9235K360000000
    11 On
    Maintained
    4SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 1/16"240V AC/240V DC9235K362000000
    21 Off and 1 On
    Maintained
    6DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 15/16"24V AC/24V DC, 120V AC/120V DC, 240V AC/240V DC9235K38000000
    22 On
    Maintained
    6DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"42 15/16"24V AC/24V DC, 120V AC/120V DC, 240V AC/240V DC9235K45000000
     
    Accessories and Replacements for Emergency Stop Switches
    Plastic Actuator Base with Screw-Terminal Wire Connection—Not Illuminated
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Pull Reset.
    Image of Product. Front orientation. Emergency Stop Switches. 30 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Not Illuminated, Twist Reset.

    Pull Reset

    Twist Reset

    Pull Reset—Turn pull switches back on by pulling the button.
    Twist Reset—Turn twist switches back on by twisting the button.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    Dp. Behind
    Panel
    Each
    Pull Reset
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K3420000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K343000000
     
    Twist Reset
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K335000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K336000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    5 amp @ 24V DC
    600V AC
    250V DC
    1 1/2"81 1/2"9235K337000000
     
    Accessories and Replacements for Emergency Stop Switches

    Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Pull Reset—Illuminated. Front orientation. Emergency Stop Switches. Metal 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Illuminated, Pull Reset.

    Pull

    Reset—Illuminated

    Immediately cut power with a single push. These switches meet EN 418 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. They include enough contact blocks to control the number of circuits listed.
    Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    IP66 Enclosure Rating, NEMA 4 Enclosure Rating, and NEMA 13 Enclosure Rating—Key reset, pull reset, illuminated pull reset, and turn reset switches are rated NEMA 4, 13, and IP66. Contact blocks for these switches are rated IP20.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    Choose a Bulb Voltage
    Each
    Pull Reset with Screw-Terminal Wire Connection—Illuminated
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K74000000
    11 On
    Maintained
    2SPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K75000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K77000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K79000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    2 3/8"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K81000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 3/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K78000000
    22 On
    Maintained
    4DPST-NC
    Red6 amp @ 120V AC
    2.5 amp @ 24V DC
    600V AC
    600V DC
    1 9/16"1 13/16"4IP20
    IP66
    NEMA 4
    NEMA 13
    24V AC/24V DC, 120V AC6741K61000000
     
    Accessories for Emergency Stop Switches
    back to top