    19 Products

    Brass and Bronze Steam Traps

    Image of Product. Front orientation. Contains Annotated. Steam Traps. Brass and Bronze Steam Traps , Style A.
    Image of Product. Front orientation. Contains Annotated. Steam Traps. Brass and Bronze Steam Traps , Style B.
    Image of Product. Front orientation. Contains Annotated. Steam Traps. Brass and Bronze Steam Traps , Style C.

    Style A

    Style B

    Style C

    These steam traps have good corrosion resistance. Also known as thermostatic steam traps, they increase the efficiency of your radiator by venting cool air. Steam traps open and close based on temperature. They are often used with convection heaters, drip lines, and risers.
    Vertical Pipeline—Steam traps with vertical pipeline orientation should be installed with the outlet pointing down.
    Inlet
    Outlet
    Style
    Pipeline
    Orientation
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Condensate
    Cap., lb/hr
    Lg.
    Each
    Brass
    AHorizontal, Vertical1/2
    NPT
    Male1/2
    NPT
    Female653103502 7/8"9840K610000000
    AHorizontal, Vertical3/4
    NPT
    Male3/4
    NPT
    Female252654303 1/8"9840K23000000
    BHorizontal1/2
    NPT
    Male1/2
    NPT
    Female252652104 1/2"9840K25000000
    BHorizontal3/4
    NPT
    Male3/4
    NPT
    Female252654305"9840K27000000
    CVertical1/2
    NPT
    Male1/2
    NPT
    Female1253501,5005 1/8"9840K33000000
     
    Bronze
    AHorizontal, Vertical1/2
    NPT
    Male1/2
    NPT
    Female25250503 1/4"1709K21000000
    AHorizontal, Vertical1/2
    NPT
    Male1/2
    NPT
    Female252501253 1/4"1709K25000000
    AHorizontal, Vertical1/2
    NPT
    Male1/2
    NPT
    Female502508753 1/4"1709K11000000
    AHorizontal, Vertical1/2
    NPT
    Male1/2
    NPT
    Female1252504,8003 1/4"1709K36000000
    AHorizontal, Vertical3/4
    NPT
    Male3/4
    NPT
    Female252501003 1/4"1709K23000000
    AHorizontal, Vertical3/4
    NPT
    Male3/4
    NPT
    Female252501253 3/8"1709K27000000
    AHorizontal, Vertical3/4
    NPT
    Male3/4
    NPT
    Female502501,2003 1/4"1709K13000000
    AHorizontal, Vertical3/4
    NPT
    Male3/4
    NPT
    Female1252506,3003 1/4"1709K38000000
     

    Stainless Steel Steam Traps

    Image of Product. Front orientation. Contains Annotated. Steam Traps. Stainless Steel Steam Traps .
    Made of 316 stainless steel, these steam traps have excellent corrosion resistance. Also known as thermostatic steam traps, they increase the efficiency of your radiator by venting cool air. They open and close based on temperature. Use with convection heaters, drip lines, and risers. Steam traps should be installed with the outlet pointing down.
    Pipe
    Size
    Thread
    Type
    Gender
    Pipeline
    Orientation
    Fitting
    Connection
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Condensate
    Cap., lb/hr
    Lg.
    Ht.
    Dia.
    Each
    316 Stainless Steel
    1/4
    NPT
    FemaleVerticalThreaded
    3005001,0002"2"1 13/16"8810T210000000
    1/2
    NPT
    FemaleVerticalThreaded
    3005001,0002 7/16"2 7/16"1 13/16"8810T22000000
    1/2
    NPT
    FemaleVerticalThreaded
    6506506503 3/4"3 3/4"1 3/4"8027K42000000
     

    Sanitary Stainless Steel Steam Traps

    Image of Product. Front orientation. Contains Annotated. Steam Traps. Sanitary Stainless Steel Steam Traps .
    Suitable for food, pharmaceutical, and other sanitary environments, these steam traps are made of 316 stainless steel with a Viton® fluoroelastomer O-ring to stand up to frequent washdowns with harsh cleaners and sanitizers. They have a smooth 20Ra interior finish—smoother than most food and dairy applications require—and a self-draining design to reduce the risk of bacteria growth. They also have quick-clamp tube fittings, which are easy to remove for cleaning and access to your line. The O-ring is FDA compliant for direct contact with food.
    Use these steam traps to increase the efficiency of your radiator by venting cool air. Also known as thermostatic steam traps, they automatically open and close based on temperature. Install them with their outlet pointing down.
    Pipe
    Size
    Gender
    Pipeline
    Orientation
    Fitting
    Connection
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Condensate
    Cap., lb/hr
    Lg.
    Ht.
    Dia.
    Food Industry Std.
    Each
    316 Stainless Steel
    1/2
    FemaleVerticalQuick Clamp
    903502,5802 5/8"2 5/8"1"FDA Compliant 21 CFR 177.2600
    3830N11000000000
    3/4
    FemaleVerticalQuick Clamp
    903502,5802 5/8"2 5/8"1"FDA Compliant 21 CFR 177.2600
    3830N1200000000
    1
    FemaleVerticalQuick Clamp
    903502,5802 5/8"2 5/8"2"FDA Compliant 21 CFR 177.2600
    3830N1300000000
     
    back to top