About Liquid Chillers
More
About Lubricants
More
Critical Application Refrigerators and Freezers
Often used for science and laboratory applications, these refrigerators and freezers provide fast cooling and quick temperature recovery after the door has been opened. An oversized fan motor helps them maintain critical temperatures. They are compact to fit under most counters. With the vent in front, they don’t require any clearance for the top, sides, and back.
They have exterior controls with a digital display to adjust the temperature in 0.1° C increments. They are accurate to ±2° C. Visual and audible alarms warn of over/under temperature and door ajar conditions.
Freezers have one removable shelf.
Refrigerators have three adjustable shelves.

Shelf | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cap., cu. ft. | Wd. | Dp. | Ht. | Freezer Temp. Setting, °C | Material | Color | Type | Total No. of | Defrost Type | Plug Type | Cord Lg., ft. | Specifications Met | Each | |
| 4.5 | 24" | 24" | 34" | -25° to -12° | Steel | White | Removable | 1 | Manual | Three Prong | 5 | CSA Certified | 0000000 | 000000000 |

Shelf | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cap., cu. ft. | Wd. | Dp. | Ht. | Refrigerator Temp. Setting, °C | Material | Color | Type | Total No. of | Ctr.-to-Ctr. Adjustments | Defrost Type | Plug Type | Cord Lg., ft. | Specifications Met | Each | |
| 5.3 | 24" | 23 3/4" | 33 3/4" | 2° to 8° | Steel | White | Adjustable | 3 | 1 1/2" | Automatic | Three Prong | 5 | CSA Certified | 0000000 | 000000000 |
Wall-Mount Refrigerated Drinking Fountains





Fountains are factory set at 50° F but can be adjusted.
Fountains with filter reduce the lead and chlorine content from drinking water. Change the filter cartridge every 1,500 gallons.
Styles C-E help comply with ADA when properly installed.
Style E has a top panel that indicates filter status.
Fountains that cannot be sold to Iowa are restricted by local requirements for drinking water.

Inlet | Mounting | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gph | Ht. | Wd. | Dp. | Tube Connection Type | For Tube OD | Drain OD | Plug Type | Fasteners Included | Hole Dia. (No. of Holes) | Specifications Met | Each | |
Fountains—Gray-Painted Steel Housing | ||||||||||||
| 13.5 | 29 1/2" | 18" | 14 1/2" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 5/16" (6) | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000000 |
| Replacement Inline Strainer for Fountains with 7.6-13.5 gph Flow Rate | 00000000 | Each | 000000 |

Inlet | Mounting | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gph | Ht. | Wd. | Dp. | Tube Connection Type | For Tube OD | Drain OD | Plug Type | Fasteners Included | Hole Dia. (No. of Holes) | Specifications Met | Each | |
Fountains | ||||||||||||
Stainless Steel Housing | ||||||||||||
| 7.8 | 37" | 18" | 9 1/2" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 1/4" (2), 5/16" (6) | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000000 |

Inlet | Mounting | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gph | Ht. | Wd. | Dp. | Tube Connection Type | For Tube OD | Drain OD | Plug Type | Fasteners Included | Hole Dia. (No. of Holes) | Specifications Met | Each | |
Fountains—Gray-Painted Steel Housing | ||||||||||||
| 8 | 18 7/8" | 18 3/8" | 19" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 9/32" (6), 7/16" (3) | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | 0000000 | 0000000 |
Fountains—Stainless Steel Housing | ||||||||||||
| 8 | 18 7/8" | 18 3/8" | 19" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 9/32" (6), 7/16" (3) | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |

Inlet | Mounting | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gph | Ht. | Wd. | Dp. | Tube Connection Type | For Tube OD | Drain OD | Plug Type | Fasteners Included | Hole Dia. (No. of Holes) | Specifications Met | Each | |
Fountains—Gray-Painted Steel Housing | ||||||||||||
| 7.6 | 23 7/8" | 18" | 18 3/4" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 5/16" (6), 1/4" (2) | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000000 |
Fountains—Stainless Steel Housing | ||||||||||||
| 7.6 | 23 7/8" | 18" | 18 3/4" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 5/16" (6), 1/4" (2) | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | 0000000 | 00000000 |

Inlet | Mounting | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gph | Ht. | Wd. | Dp. | Tube Connection Type | For Tube OD | Drain OD | Plug Type | Fasteners Included | Hole Dia. (No. of Holes) | Specifications Met | Cannot Be Sold To | Each | |
Fountains with Filter—Gray-Painted Steel Housing | |||||||||||||
| 8 | 39 1/8" | 18" | 19" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | 9/32" (9), 7/16" (9) | NSF/ANSI 61, NSF/ANSI 372, C-UL Listed, CSA Certified, UL 399 | IA | 0000000 | 000000000 |
Refrigerated Drinking Fountains



Fountains are factory set at 50° F but can be adjusted.
Fountains with filter reduce the lead and chlorine content from drinking water. Change the filter cartridge every 1,500 gallons.
Fountains that cannot be sold to Iowa are restricted by local drinking water requirements.
Inlet | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Flow Rate, gph | Ht. | Wd. | Dp. | Tube Connection Type | For Tube OD | Drain OD | Plug Type | For Use Outdoors | Specifications Met | Cannot Be Sold To | Each | |
Beige-Painted Steel Housing | |||||||||||||
Fountains with Filter | |||||||||||||
| A | 3 | 38 7/8" | 12" | 12" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | IA | 00000000 | 000000000 |
Gray-Painted Steel Housing | |||||||||||||
Fountains | |||||||||||||
| B | 7.6 | 41 1/2" | 18" | 14 1/2" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | __ | 0000000 | 00000000 |
| B | 19.5 | 41 1/2" | 18" | 14 1/2" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | __ | 0000000 | 00000000 |
| C | 7.6 | 41 1/2" | 18" | 14 1/2" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | __ | 0000000 | 00000000 |
Light Gray-Painted Steel Housing | |||||||||||||
Fountains | |||||||||||||
| A | 3 | 38 7/8" | 12" | 12" | Solder Connect | 3/8" | 1 1/4" | Three Prong | No | NSF/ANSI 61, NSF/ANSI 372, UL Listed, C-UL Listed, CSA Certified | __ | 0000000 | 00000000 |
Drinking Water Chillers

Attach one of these chillers to your nonrefrigerated drinking fountains to provide cold water. You can also install a bottle filler or drinking fountain nozzle directly to the unit. Made of galvanized steel for corrosion resistance, chillers are factory set at 50° F but can be adjusted. They meet NSF/ANSI safety standards for use with drinking water. Chillers need 6” clearance in front of the unit and 3” behind the unit for proper ventilation.
Inlet | Outlet | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gph | For No. of Fountains/Fillers | Wd. | Dp. | Ht. | Tube Connection Type | For Tube OD | Tube Connection Type | For Tube OD | Electrical Connection Type | Motor Power, hp | Current, A | Voltage | Specifications Met | Each | |
| 1.5 | 1 | 17" | 7" | 14" | Solder Connect | 1/4" | Solder Connect | 1/4" | Wire Leads | 1/18 | 2 | 120V AC | NSF/ANSI 61, UL Listed | 0000000 | 0000000 |
| 10 | 2 | 19 1/2" | 7 7/8" | 22" | Solder Connect | 3/8" | Solder Connect | 3/8" | Wire Leads | 1/4 | 6 | 120V AC | NSF/ANSI 61, UL Listed | 0000000 | 00000000 |
High-Flow Liquid Chillers



For more cooling capacity than other liquid chillers, these have a heavy duty pump that can handle higher flow rates and pressures. They provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. All have an internal tank to ensure liquid flows in a continuous loop. They are used to cool liquid in process equipment. Adjust the set temperature with the keypad.
Chillers rated for 4,300, 11,300, and 69,000 Btu/hr. have a cooling capacity based on a 65° F liquid temperature and a 95° F room temperature.
Chillers rated for 24,000 to 36,000 Btu/hr. have a cooling capacity based on a 65° F liquid temperature and a 90° F room temperature.
Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Features | Each | |
For Closed Loop Systems | ||||||||||||||
| 4,300 | 120V AC (Single) | 15.5A | 1/2 | 4 gpm @ 50 psi | 50 | 50° to 80° | 28 5/8" | 22" | 21 1/8" | 5 | R-407C | Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
| 11,300 | 240V AC (Single) | 17A | 1 | 4 gpm @ 50 psi | 50 | 50° to 80° | 33 3/8" | 31 1/8" | 25 1/8" | 10 | R-407C | Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
| 24,000 | 240V AC (Single) | 34A | 3 1/2 | 10 gpm @ 35 psi | 35 | 50° to 80° | 35 11/16" | 33 1/2" | 31 5/8" | 10 | R-407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
| 24,000 | 240V AC (Three) | 22A | 2 | 10 gpm @ 35 psi | 35 | 50° to 80° | 35 11/16" | 33 1/2" | 31 5/8" | 10 | R-407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
| 36,000 | 460V AC (Three) | 11A | 3 | 10 gpm @ 45 psi | 45 | 50° to 80° | 65" | 37" | 34 1/2" | 36 | R-407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
| 69,000 | 460V AC (Three) | 15A | 5 | 15 gpm @ 45 psi | 45 | 50° to 80° | 65" | 37" | 34 1/2" | 36 | R-407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
Precision Liquid Chillers

These liquid chillers maintain a stable temperature within 0.18° F for the most precise temperature control. They provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. All have an internal tank to ensure liquid flows in a continuous loop. Use them to cool liquid in process equipment. Adjust the set temperature with the keypad.
Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Each | |
For Closed-Loop/Open-Loop Systems | |||||||||||||
| 2,900 | 120V AC (Single) | 13.7A | 1/4 | 3.5 gpm @ 0 psi | 90 | 15° to 155° | 21 7/8" | 15" | 26" | 1.1 | R-513A | 0000000 | 000000000 |
| 5,940 | 120V AC (Single) | 17.4A | 1/2 | 3.5 gpm @ 0 psi | 90 | 15° to 155° | 21 7/8" | 15" | 26" | 1.1 | R-513A | 0000000 | 00000000 |
| 9,900 | 230V AC (Single) | 13.5A | 1 | 3.5 gpm @ 0 psi | 90 | 15° to 155° | 21 7/8" | 15" | 26" | 1.1 | R-513A | 0000000 | 00000000 |
Welding Water Coolers
Cool welding guns and torches with these recirculating coolers. The outlet connects to a hose running to your welder or torch, and the inlet connects to a hose running back from your welder or torch. Coolers can also be used in plasma applications.


Input | Inlet and Outlet Hose Connection | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Capacity, gal. | Max. Flow Rate, gpm | Lg. | Wd. | Ht. | Wt., lbs. | Voltage | Current, A | For Max. Welder Current, A | Cooling Capacity, Btu/hr. | Thread Size | Gender | Thread Type | Thread Direction | Specifications Met | Each | |
MIG, TIG, Spot, Stud Welding Process | ||||||||||||||||
| 3 | 1.05 | 23" | 12" | 13" | 40 | 120V AC | 4.7, 5.9 | 500 | 13,000 | 5/8"-18 | Female | UNF | Left Hand | CE Marked | 0000000 | 000000000 |
| 4 | 1.47 | 19" | 15" | 16" | 38 | 120V AC | 4.7, 5.9 | 600 | 18,000 | 5/8"-18 | Female | UNF | Left Hand | CE Marked | 0000000 | 00000000 |

| For Manufacturer | Each | |
| Bernard, Dynaflux, Lincoln, Miller | 0000000 | 0000000 |
Coolants for Welding Water Coolers

Weld longer without damaging your torch—replace the water in your welding cooler with these coolants to prevent mineral deposits and frozen lines. Coolants also tolerate colder temperatures than water—the more ethylene glycol in the coolant, the lower temperatures it can withstand. For use with MIG, TIG, spot, and stud welders. They are nonconductive.
Container | ||||||
|---|---|---|---|---|---|---|
| Size, gal. | Type | Percentage of Ethylene Glycol | Welding Process | Compatible With | Each | |
Synthetic Base Oil | ||||||
| 1 | Jug | 17% | MIG, TIG, Spot, Stud | Aluminum, Brass, Carbide, Cast Iron, Copper, Fiberglass, Glass, Iron, Nickel, Plastic, Rubber, Stainless Steel, Steel, Titanium | 0000000 | 000000 |
| 1 | Jug | 56% | MIG, TIG, Spot, Stud | Aluminum, Brass, Carbide, Cast Iron, Copper, Fiberglass, Glass, Iron, Nickel, Plastic, Rubber, Stainless Steel, Steel, Titanium | 0000000 | 00000 |

























