Control Current
Timer Relays
Timer Relays | Sockets | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Switching Current, amp | ||||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | No. of | Overall | @ 240 V AC | @ 24 V DC | Max. Switching Voltage | hp @ Switching Voltage | Timing Adjustment Style | Each | Each | ||||
Delayed Start (Delay on Make) | |||||||||||||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | |||||||||||||||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.05 sec. to 1 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K21 | 000000 | 7122K19 | 00000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.1 sec. to 10 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K23 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.3 sec. to 30 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K24 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec. to 60 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K25 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 1.8 sec. to 180 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K26 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 3 sec. to 300 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K51 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.1 min. to 10 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K52 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.6 min. to 60 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K54 | 00000 | 7122K19 | 0000 | ||
Delayed Switch Off (Delay on Break) | |||||||||||||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | |||||||||||||||
| 11 | 120V AC, 120V DC | 17 | 1 | 0.05 sec. to 5 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K42 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 0.1 sec. to 10 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K43 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 0.3 sec. to 30 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K44 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 0.6 sec. to 60 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K45 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 1.2 sec. to 120 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K4 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 1.8 sec. to 180 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K46 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 3 sec. to 300 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K61 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 0.1 min. to 10 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K62 | 00000 | 7122K21 | 0000 | ||
| 11 | 120V AC, 120V DC | 17 | 1 | 0.6 min. to 60 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7268K64 | 00000 | 7122K21 | 0000 | ||
Interval | |||||||||||||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | |||||||||||||||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.05 sec. to 5 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K31 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec. to 60 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K32 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.1 min. to 10 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K33 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.6 min. to 60 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K34 | 00000 | 7122K19 | 0000 | ||
Repeat Cycle | |||||||||||||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | |||||||||||||||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.05 sec. to 5 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K11 | 000000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.1 sec. to 10 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K12 | 000000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec. to 60 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K14 | 000000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 1.8 sec. to 180 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K16 | 000000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 3 sec. to 300 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K17 | 000000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.1 min. to 10 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K18 | 000000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.3 min. to 30 min. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K23 | 000000 | 7122K19 | 0000 | ||
Switch on (Single Shot) | |||||||||||||||
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.1 sec. to 10 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K41 | 00000 | 7122K19 | 0000 | ||
| 8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec. to 60 sec. | 10 | 8 | 240V AC/30V DC | 1/3 hp @ 240V AC | Knob | 7630K42 | 00000 | 7122K19 | 0000 | ||
Solid State Versa-Mount Multifunction Timer Relays
Timer Relays | Sockets | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | |||||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Ht. | Wd. | Dp. | Each | Each | ||||
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||||
| 11 | 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 17 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 7 | 0.1 sec. to 999 hr. | 3 amp @ 240V AC | 1.9" | 1.9" | 2.7" | 6963K14 | 0000000 | 7122K21 | 00000 | ||
Multifunction Timer Relays
Timer Relays | Sockets | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | ||||||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Each | Each | ||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | ||||||||||||||||
Relay-Socket Mount | ||||||||||||||||
| 11 | 120V AC | 17 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 5 | 0.05 sec. to 999 min. | 10 amp @ 240V AC | 240 | 2.4" | 1.8" | 3.7" | 6964K16 | 0000000 | 7122K21 | 00000 | ||
Circuit Board Safety Relays
No. of Terminals | Input Voltage, V DC | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Pin Lg. | Features | Surge Suppression Coverage | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4 Circuits Controlled with 2 Off and 2 On—4PST-2NO/2NC | |||||||||||||||
| 10 | 24 | 17 | 6 amp @ 240V AC/30V DC | 250V AC, 125V DC | 10,000,000 | 1.6" | 0.5" | 1" | 0.14" | Interlocked Opposing Contacts, LED Indicator | Full | 6253N26 | 000000 | ||
4 Circuits Controlled with 3 Off and 1 On—4PST-3NO/1NC | |||||||||||||||
| 10 | 24 | 17 | 6 amp @ 240V AC/30V DC | 250V AC, 125V DC | 10,000,000 | 1.6" | 0.5" | 1" | 0.14" | Interlocked Opposing Contacts, LED Indicator | Full | 6253N28 | 00000 | ||