Filter by
Switching Voltage
Timer Relay Function
Timing Adjustment Style
Mounting Location
Socket Connection
Overall Timing
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Switch Starting Position
Certification
Control Current
Mechanical Life Cycles
Horsepower @ Switching Voltage
Operation Type
About Timer Relays
More
Latching Relays

10-Terminal Relay

10-Terminal Relay Socket
A single, momentary input voltage switches these relays and latches them in position, so they don't require a constant input voltage to stay switched. A second momentary voltage will release the latch.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Timer Relays

Relay with Push Button

Relay with DIP Switches

Relay Socket
Turn machinery, such as paint and conveyor lines, on and off after a set period of time. These timer relays plug into relay sockets (sold separately) for fast installation and replacement.
Relay sockets mount on 35 mm DIN rail (also known as DIN 3) or flat surfaces.
Timer Relays | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Switching Current | Relay Sockets | |||||||||||
| Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | @ 240V AC | @ 24V DC | Max. Switching Voltage | hp @ Switching Voltage | Timing Adjustment Style | Each | Each | ||
Delayed Start (Delay-on-Make) | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
| 8 | 120V AC | 27 | 5 | 0.05 sec.-999 min. | 10A | __ | 240V AC | __ | Push Button | 000000 | 0000000 | 0000000 | 00000 |
Interval | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
| 8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
Switch-On (Single-Shot) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
| 8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
Delayed Switch-Off (Delay-on-Break) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
| 8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
Repeat Cycle | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
| 8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |