Spade-Terminal Relays
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface mount relays, also known as power relays, have a slot on the flange for mounting them to flat surfaces.
Relay-socket mount relays, also known as ice cube relays, offer three ways to connect. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals.
Relay-socket/surface mount relays can plug into a socket or mount to a flat surface.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They can also mount to a flat surface.



Relays | Relay Sockets with Screw Terminals | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
| 5 | 24V AC | 84 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 000000 | 0000000 | 000000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
| 8 | 24V AC | 84 | 250V AC | 1/2 hp @ 240 V AC 1/3 hp @ 120 V AC | 1.4" | 1.5" | 1.9" | 0.187" | 0000000 | 00000 | 0000000 | 00000 |
Circular-Pin Relays



8-Terminal
Relay

The circular pin terminals plug into relay sockets for easy installation. Also known as ice cube relays.
Relays rated for horsepower (hp) are built to handle tough, repetitive-use applications.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) or can be mounted to a flat surface.
Relays | Relay Sockets | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||
| 8 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | 000000 | 000000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||
| 8 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | 0000000 | 00000 | 0000000 | 0000 |
3 Circuits Controlled with 3 Off (Normally Open) or 3 On (Normally Closed)—3PDT | |||||||||||
| 11 | 24V AC | 84 | 10 A @ 240 V AC/28 V DC | 1/3 hp @ 120 V AC 1/2 hp @ 240 V AC | 1.4" | 1.4" | 2" | 0000000 | 00000 | 0000000 | 00000 |