McMaster-Carr logo
    Filter by
    System of Measurement
    Input Voltage
    Industrial Info Snippet
    Number of Circuits Controlled
    Number of Terminals
    Switching Current
    Industrial Info Snippet
    Mounting Location
    Width
    Operation Type
    Electrical Connection
    Depth
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Mechanical Life Cycles
    Pin Length
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    UL File Number
    Switch Action
    Height
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    20 Products

    Circuit Board Safety Relays

    Image of Specification. Front orientation. Contains Annotated. Safety Relays. Circuit Board Safety Relays, 10 Terminals.
    Image of Specification. Front orientation. Contains Annotated. Safety Relays. Circuit Board Safety Relays, 14 Terminals.

    10 Terminals

    14

    Terminals

    Reduce connection errors on circuit boards that control machine guards and other safety devices. Also known as force-guided contact relays, they have contact pairs that won’t close at the same time, even if contacts stick or weld shut. These relays take up less space on a board than those with electrical wiring because their solder pin terminals mount directly through circuit board holes. Use them to control high-power components, such as fans and heaters, from a low-power circuit.
    Surge Suppression Coverage—Relays with surge suppression coverage protect sensitive electronics from damage and malfunction by eliminating voltage spikes. Switching off a relay can generate surges of 300 to 500 volts, but a diode within these relays suppresses these surges. An LED indicator on these relays lights up when they’re on, so you know at a glance if they’re wired correctly.
    No. of
    Terminals
    Input Voltage,
    V DC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Mechanical
    Life Cycles
    Ht.
    Wd.
    Dp.
    Pin
    Lg.
    Features
    Surge Suppression
    Coverage
    Each
    4 Circuits Controlled with 2 Off and 2 On—4PST-2NO/2NC
    1012306 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts6253N15000000
    1012326 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N2500000
    1024156 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts6253N1400000
    1024176 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N2600000
     
    4 Circuits Controlled with 3 Off and 1 On—4PST-3NO/1NC
    1012306 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts6253N1600000
    1012326 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N2700000
    1024156 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts6253N1700000
    1024176 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0001.6"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N2800000
     
    6 Circuits Controlled with 3 Off and 3 On—6PST-3NO/3NC
    1412416 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts6253N1800000
    1412436 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N2900000
    1424206 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts6253N1900000
    1424226 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N3100000
     
    6 Circuits Controlled with 4 Off and 2 On—6PST-4NO/2NC
    1412416 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts6253N2100000
    1412436 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N3200000
    1424206 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts6253N2200000
    1424226 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N3300000
     
    6 Circuits Controlled with 5 Off and 1 On—6PST-5NO/1NC
    1412416 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts6253N2400000
    1412436 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N3400000
    1424206 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts6253N2300000
    1424226 amp @ 240V AC/30V DC250V AC, 125V DC10,000,0002"0.5"1"0.14"Interlocked Opposing Contacts, LED IndicatorFull6253N3500000
     
    back to top