    110 Products

    Enclosed Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Enclosed Relays.
    An enclosure covers the terminals on these relays to help prevent damage from dust or accidental bumps. They have an LED indicator, so you can quickly see what switching position your relay is in. Hardwire them to your equipment with the included wire leads. Rated NEMA 1, these relays are intended for indoor use only.
    Wire
    Lead
    Conduit
    Connection
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching Voltage
    Ht.
    Wd.
    Dp.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Enclosure
    Rating
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Conduit-Hub Mount
    24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC4010 amp @ 277V AC2771/2 hp @ 120V AC
    1/4 hp @ 277V AC
    1.7"2.8"1.5"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N18000000
    24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 30V DC4720 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    2.4"3.3"1.8"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1700000
     
    2 Circuits Controlled with 2 Off—DPST-NO
     
    Conduit-Hub Mount
    120V AC10530 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    4"4"1.8"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1200000
    208V AC, 240V AC, 277V AC10530 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    4"4"1.8"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1300000
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
     
    Conduit-Hub Mount
    24V AC, 120V AC, 24V DC, 30V DC3110 amp @ 277V AC2771.7"2.8"1.5"16"8Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1400000
    24V AC, 208V AC, 240V AC, 277V AC, 24V DC, 30V DC3610 amp @ 277V AC2771.7"2.8"1.5"16"8Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1600000
    24V AC, 208V AC, 240V AC, 277V AC, 30V DC14020 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    2.4"3.3"1.8"16"8Male3/4
    NPT
    NEMA 1
    LED Indicator6628N1500000
    120V AC10520 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    4"4"1.8"16"8Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1100000
     

    Wireless Enclosed Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Wireless Enclosed Relays.
    Send a signal to turn equipment on and off from up to 150 feet away without having to run electrical wire. These relays have an enclosure to protect the terminals from dust and accidental bumps. They can be set to transmit, receive, or both at once. You’ll need at least two relays to switch a device. They have an alarm that can be set to check for certain conditions before transmitting a signal. For example, you could set these relays to send a signal to turn on an air conditioner if all windows are closed. The repeat function extends the transmitting signal through a maximum of two receiving relays.
    Relays that are set to transmit can be linked up to as many receiving relays as you need. Relays set to receive can be linked up to 30 transmitting relays. All relays connect to dry contacts on your switch, sensor, or controller. Use the wire leads to connect them to a power source.
    UL and C-UL listed, all meet American and Canadian safety standards. Rated NEMA 1, they should only be used indoors.
    Wire
    Lead
    Conduit
    Connection
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching
    Voltage
    Ht.
    Wd.
    Dp.
    Max. Transmission
    Distance, ft.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Enclosure
    Rating
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Conduit-Hub Mount/Surface Mount
    24V AC, 24V DC6920 amp @ 277V AC2772 hp @ 277V AC2.3"3.2"1.8"15016"7Male1/2
    NPT
    NEMA 1
    Alarm, Repeat Function3918N150000000
    120V AC7320 amp @ 277V AC2772 hp @ 277V AC2.3"3.2"1.8"15016"7Male1/2
    NPT
    NEMA 1
    Alarm, Repeat Function3918N11000000
    208V AC8020 amp @ 277V AC2772 hp @ 277V AC2.3"3.2"1.8"15016"7Male1/2
    NPT
    NEMA 1
    Alarm, Repeat Function3918N12000000
    240V AC8020 amp @ 277V AC2772 hp @ 277V AC2.3"3.2"1.8"15016"7Male1/2
    NPT
    NEMA 1
    Alarm, Repeat Function3918N13000000
    277V AC8020 amp @ 277V AC2772 hp @ 277V AC2.3"3.2"1.8"15016"7Male1/2
    NPT
    NEMA 1
    Alarm, Repeat Function3918N14000000
     

    Backup Power Supplies for Facility Lights

    Relays
    Image of Product. Back orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Relays, Unthreaded Through-Hole Mount.
    Image of Product. Front orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Relays, Fastener Mount.

    Unthreaded

    Through-Hole

    Mount

    Fastener Mount

    Relays have an LED indicator that tells you if your lights are using primary or backup power and when these relays require maintenance. They also have a test switch to make sure the system is working.
    Unthreaded Through-Hole Mount—Relays that mount into an unthreaded through hole install into knockouts in junction boxes and light fixtures.
    Fastener Mount—Fastener-mount relays are ideal when space is tight or you want to hide your relay. They fit inside a ballast channel to keep everything contained within your fixture housing.
    Overall
    Mounting
    Holes
    Wire
    Lead
    Conduit
    Connection
    Input Voltage,
    V AC
    Output Voltage,
    V AC
    Control Current,
    mA
    Switching
    Current, amp
    Max. Switching
    Voltage, V AC
    Mechanical
    Life Cycles
    Trip Time,
    sec.
    Ht.
    Wd.
    Dp.
    Battery
    Test Type
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Temp.,
    ° F
    Features
    Enclosure
    Rating
    Specifications Met
    Each
    1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO
     
    Unthreaded Through-Hole Mount
    120 to 277120 to 2771182027710,000,0000.0184"4"1 3/4"ManualYes40.19"16"6Male1/2
    NPT
    -30 to 140Test Switch, LED IndicatorNEMA 1
    NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed, CE Marked8197N120000000
     
    Fastener Mount
    120 to 277120 to 2771181027710,000,0000.0181 3/4"4 3/4"1 1/4"ManualNo20.19"16"10-30 to 140Test Switch, LED IndicatorNEMA 1
    NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed, CE Marked8197N13000000
     
    Remote Testing Buttons for Relays

    Manual Transfer Switches

    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1.
    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1 with NEMA 3R Power Inlet Box.

    NEMA 1

    NEMA 1 with NEMA 3R

    Power Inlet Box

    If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
    Use them with a portable generator.
    NEMA 1—NEMA 1 switches should be used indoors.
    NEMA 1 with NEMA 3R Power Inlet Box—NEMA 1 switches with a power inlet box create a connection point between the switch and a portable generator. These switches should be used indoors. But their inlet box is rated NEMA 3R, so it can be mounted on the outside of an exterior wall.
    Housing
    Mounting
    Max. Power,
    W
    Switching Current
    (No. of Switches)
    Circuit Breaker Breakthrough
    Current, amp
    Electrical
    Phase
    Housing Material
    Ht.
    Wd.
    Dp.
    Generator Connection
    NEMA Type
    Power Cord
    Lg., ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Certification
    Specs. Met
    Each
    NEMA 1
     
    10 Circuits Controlled
    7,50030 amp @ 240V AC (1 DPDT)
    20 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N180000000
     
    NEMA 1 with NEMA 3R Power Inlet Box
     
    6 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (4 SPDT)
    10,000SinglePowder-Coated Steel12"8 3/4"6"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N11000000
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N12000000
     

    Enclosed Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Heavy Duty Motor Starters.
    Housed in a durable steel enclosure, these starters have sealed coils for protection against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Tripping
    Accuracy
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
     
    NEMA Contact Size 0
    0.25 to 124Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K34100000007463K7110000000
    0.25 to 1110/240Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3420000007463K712000000
    0.25 to 1208Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3430000007463K713000000
    0.75 to 3.424Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3510000007463K711000000
    0.75 to 3.4110/240Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3520000007463K712000000
    0.75 to 3.4208Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3530000007463K713000000
    0.75 to 3.4220/480Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3540000007463K714000000
    3 to 1224Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4210000007463K711000000
    3 to 12110/240Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4220000007463K712000000
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4230000007463K713000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4240000007463K714000000
    5.5 to 2224Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4310000007463K711000000
    5.5 to 22110/240Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4320000007463K712000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4330000007463K713000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4340000007463K714000000
     
    NEMA Contact Size 1
    3 to 1224Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4510000007463K711000000
    3 to 12110/240Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4520000007463K712000000
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4530000007463K713000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4540000007463K714000000
    5.5 to 2224Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4610000007463K711000000
    5.5 to 22110/240Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4620000007463K712000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4630000007463K713000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4640000007463K714000000
    10 to 4024Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4710000007463K711000000
    10 to 40110/240Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4720000007463K712000000
    10 to 40208Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4730000007463K713000000
    10 to 40220/480Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4740000007463K714000000
     
    NEMA Contact Size 2
    13 to 5224Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K521000000007463K711000000
    13 to 52110/240Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K522000000007463K712000000
    13 to 52208Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K523000000007463K713000000
    13 to 52220/480Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K524000000007463K714000000
     

    Build-Your-Own Manual Motor Starters

    Assemble your own motor starter by combining a switch and a thermal overload element.
    Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s power and voltage).
    Switches with Power-Indicating Light
    Image of Product. Front orientation. Motor Starters. Build-Your-Own Manual Motor Starters, Switches with Power-Indicating Light, Steel Housing.

    Steel Housing

    No. of Circuits
    Controlled
    Electrical Phase
    Ht.
    Wd.
    Wire
    Connection
    Enclosure
    Rating
    Environment
    Each
    Steel Housing
    1Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K270000000
    2Single (3/4 hp @ 115V DC)
    Single (3/4 hp @ 230V DC)
    Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K37000000
     
    Switches without Power-Indicating Light
    Image of Product. Front orientation. Motor Starters. Build-Your-Own Manual Motor Starters, Switches, Steel Housing.

    Steel Housing

    No. of Circuits
    Controlled
    Electrical Phase
    Ht.
    Wd.
    Wire
    Connection
    Enclosure
    Rating
    Environment
    Each
    Steel Housing
    1Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K23000000
    2Single (3/4 hp @ 115V DC)
    Single (3/4 hp @ 230V DC)
    Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K33000000
     

    Automatic Transfer Switches for Facility Lights

    Image of Product. Front orientation. Transfer Switches. Automatic Transfer Switches for Facility Lights.
    Restore lighting immediately during power outages. These switches detect when your main power source goes out and shift your lights to a backup, such as a secondary utility source or generator. To comply with UL 924 and help you meet NFPA standards, they turn your lights on at full brightness even if the lights were turned off or dimmed. You can also wire these switches to your fire alarm. Pull the alarm to activate lights to full brightness during emergencies, even without an outage. All have passed testing to meet UL 1008, a safety standard for transfer switches.
    An LED indicator tells you whether lights are running on a primary or backup power source. The indicator also tells you when these switches require maintenance.
    Remote Testing Buttons—Add a remote testing button to check if switches behind the wall or ceiling are working properly.
    Switches
    Remote
    Testing Buttons
    Switching
    Housing
    Mounting
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical
    Phase
    For No.
    of Wires
    Housing Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Features
    Certification
    Specs. Met
    Each
    Each
    NEMA 1
    16120 to 277DPDT
    Single4Powder-Coated Steel8 5/16"7 11/16"3 15/16"No41/4"LED IndicatorETL Listed, CE Marked
    UL 924, UL 10087934N1100000008197N11000000
     

    Enclosed Heavy Duty Build-Your-Own Manual Motor Starters

    Image of Product. Thermal Overload Protectors. Front orientation. Motor Starters. Enclosed Heavy Duty Build-Your-Own Manual Motor Starters.
    Image of Product. Switch with NEMA 1 Enclosure Rating. Front orientation. Motor Starters. Enclosed Heavy Duty Build-Your-Own Manual Motor Starters, NEMA 1 Enclosure Rating.

    Thermal

    Overload

    Protectors

    Switch with NEMA

    1 Enclosure

    Rating

    Combine a switch with a thermal overload element to build a starter that can handle high-current-rated motors. All are housed in a durable steel enclosure. They’re also known as NEMA starters.
    Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s power and voltage).
    Switches
    Thermal
    Overload Elements
    NEMA Contact
    Size
    Electrical Phase
    Housing
    Material
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Certification
    Each
    Each
    NEMA 1 Enclosure Rating
    M-0Three (2 hp @ 115V AC)
    Three (3 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Painted Steel7.6"4.7"5"Screw TerminalUL Listed, CSA Certified
    7595K6200000007595K2000000
    M-1Three (3 hp @ 115V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Painted Steel7.6"4.7"5"Screw TerminalUL Listed, CSA Certified
    7595K26000000007595K200000
     