    66 Products

    DIN-Rail Mount Solid State Relays

    Image of Product. Relay with Integrated Heat Sink. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Solid State Relays.
    Image of Product. Relay with Integrated Heat Sink and Fan. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Solid State Relays.
    Image of Product. Relay. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Solid State Relays.

    Relay with

    Integrated Heat

    Sink

    Relay with Integrated Heat

    Sink and Fan

    Relay

    Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, switch faster, and are quieter. They mount on 35 mm DIN rail (also known as DIN 3) for fast installation. An LED indicator lights up when these relays are connected, so you can quickly confirm that they’re wired correctly. IP20 rated, their terminals are recessed, so they prevent fingers and other objects from touching live circuits.
    Integrated Heat Sink—Relays with an integrated heat sink disperse heat to increase the relay’s current rating.
    Integrated Fan—Relays with an integrated fan are best for applications that generate more heat. The fan automatically turns on to provide additional cooling. When the temperature exceeds 176° F, an alarm sends a signal to an external device, such as a controller or indicating light.
    No. of
    Terminals
    Input Voltage
    Control Current,
    mA
    Switching Current @
    Voltage (Load Type)
    Max. Switching
    Voltage, V AC
    hp @ Switching Voltage
    Ht.
    Wd.
    Dp.
    Features
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Single Phase
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC1320 amp @ 240V AC (Full)2641/3 hp @ 115V AC
    1 hp @ 230V AC
    4.33"0.7"3.447"Integrated Heat Sink, LED Indicator4398N12000000
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC1320 amp @ 600V AC (Full)6601/3 hp @ 115V AC
    1 hp @ 230V AC
    4.33"0.7"3.447"Integrated Heat Sink, LED Indicator6323T4100000
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC1330 amp @ 230V AC (Full)2643/4 hp @ 115V AC
    2 hp @ 230V AC
    4.33"0.89"4.917"Integrated Heat Sink, LED Indicator7456K78000000
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC1385 amp @ 600V AC (Full)6602 hp @ 115V AC
    5 hp @ 230V AC
    5.12"2.76"5.247"Integrated Heat Sink, Integrated Fan, LED Indicator6323T81000000
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC2230 amp @ 600V AC (Full)6603/4 hp @ 115V AC
    2 hp @ 230V AC
    4.33"0.89"4.917"Integrated Heat Sink, LED Indicator6323T32000000
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC2240 amp @ 600V AC (Full)6601 hp @ 115V AC
    3 hp @ 230V AC
    4.33"1.4"4.917"Integrated Heat Sink, LED Indicator6323T34000000
     
    2 Circuits Controlled with 2 Off—DPST-NO
     
    Three Phase
    824V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC225 amp @ 220V AC (Full)2421 1/2 hp @ 115V AC
    3 hp @ 230V AC
    4.33"2.13"3.427"Integrated Heat Sink, LED Indicator7456K81000000
    824V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC225 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    4.33"2.13"3.427"Integrated Heat Sink, LED Indicator7456K82000000
    824V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC240 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    4.33"2.84"4.66"Integrated Heat Sink, LED Indicator6323T83000000
    1524V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC275 amp @ 600V AC (Full)66010 hp @ 230V AC
    20 hp @ 480V AC
    5.55"2.84"4.679"Integrated Heat Sink, Integrated Fan, LED Indicator6323T85000000
     
    3 Circuits Controlled with 3 Off—3PST-NO
     
    Three Phase
    824V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC220 amp @ 600V AC (Full)6603 hp @ 230V AC
    7 1/2 hp @ 480V AC
    4.33"2.1"3.427"Integrated Heat Sink, LED Indicator6323T71000000
    824V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC230 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    4.33"2.84"4.66"Integrated Heat Sink, LED Indicator6323T87000000
    1524V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC240 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    5.31"2.13"3.739"Integrated Heat Sink, Integrated Fan, LED Indicator6323T89000000
    1524V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC265 amp @ 600V AC (Full)66010 hp @ 230V AC
    20 hp @ 480V AC
    5.55"2.84"4.679"Integrated Heat Sink, Integrated Fan, LED Indicator6323T92000000
     

    Smart Multifunction Monitoring Relays

    Image of ProductInUse. Front orientation. Monitoring Relays. Smart Multifunction Monitoring Relays.
    Remotely control these relays through an app on your smartphone—they simultaneously monitor phase, voltage, and frequency. The downloadable app lets you change the tripping range, modify settings, and save programs to apply to multiple relays. Tap your smartphone or tablet to the relays to connect to them. They use NFC (near field communication), so you don’t need to manually pair them like Bluetooth devices.
    You’ll often see these relays used to protect motors, generators, and other three-phase circuits from burning out or overheating. They'll switch the circuit off if they detect voltage or frequencies outside of the set range or phase loss, imbalance, or reversal. You can see that they're wired correctly and when they're actuated based on the LED indicators. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    No. of
    Terminals
    Input Voltage, V AC
    Trip Voltage,
    V AC
    Input Freq.,
    Hz
    Trip Freq.,
    Hz
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Operating System Compatibility
    Each
    2 Circuits Controlled with 2 Off or 2 On—DPDT
     
    With Screw Terminals
    12208, 240, 300, 480208 to 48050, 6045 to 660.1 to 60Automatic8 amp @ 240V AC2503.5"0.9"3.9"Android 7.0 or Later, iOS 14.5 or Later8452N110000000
     

    Enclosed Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Enclosed Relays.
    An enclosure covers the terminals on these relays to help prevent damage from dust or accidental bumps. They have an LED indicator, so you can quickly see what switching position your relay is in. Hardwire them to your equipment with the included wire leads. Rated NEMA 1, these relays are intended for indoor use only.
    Wire
    Lead
    Conduit
    Connection
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching Voltage
    Ht.
    Wd.
    Dp.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Enclosure
    Rating
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Conduit-Hub Mount
    24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC4010 amp @ 277V AC2771/2 hp @ 120V AC
    1/4 hp @ 277V AC
    1.7"2.8"1.5"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N18000000
    24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 30V DC4720 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    2.4"3.3"1.8"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1700000
     
    2 Circuits Controlled with 2 Off—DPST-NO
     
    Conduit-Hub Mount
    208V AC, 240V AC, 277V AC10530 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    4"4"1.8"16"6Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1300000
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
     
    Conduit-Hub Mount
    24V AC, 208V AC, 240V AC, 277V AC, 24V DC, 30V DC3610 amp @ 277V AC2771.7"2.8"1.5"16"8Male1/2
    NPT
    NEMA 1
    LED Indicator6628N1600000
    24V AC, 208V AC, 240V AC, 277V AC, 30V DC14020 amp @ 277V AC2771 hp @ 120V AC
    2 hp @ 277V AC
    2.4"3.3"1.8"16"8Male3/4
    NPT
    NEMA 1
    LED Indicator6628N1500000
     

    Infrequent-Cycle Relays

    Image of Product. 1 Circuit. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 2 Terminals.
    Image of Product. 2 Circuits. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 4 Terminals.
    Image of Product. 3 Circuits. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 6 Terminals.
    Image of Product. 4 Circuits. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 8 Terminals.

    1 Circuit

    2 Circuits

    3 Circuits

    4 Circuits

    For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
    Auxiliary contacts for 3.8"-7.2" Ht. relays are also available. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on or off.
    Switching Current
    @ 600V AC, amp
    hp @
    Switching Voltage
    No. of
    Terminals
    Input Voltage,
    V AC
    Control
    Power, VA
    Full
    Load
    Resistive
    Load
    Single Phase
    Three Phase
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Quick-Disconnect × Screw Terminal
    2208, 240625302 hp @ 115V AC
    3 hp @ 230V AC
    3.2"2"2.3"0.25"6564K853000000
    2208, 240630402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K72600000
    2208, 240640503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K863000000
     
    2 Circuits Controlled with 2 Off—DPST-NO
     
    Quick-Disconnect × Screw Terminal
    4208, 2406.520301 1/2 hp @ 115V AC
    3 hp @ 230V AC
    3.2"2"2.3"0.25"6564K73600000
    4208, 2406.525352 hp @ 115V AC
    3 hp @ 230V AC
    3.2"2"2.3"0.25"6564K74600000
    4208, 2406.530402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K75600000
    4208, 2406.540503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K766000000
    4208, 240715203/4 hp @ 115V AC
    2 hp @ 230V AC
    3 hp @ 230V AC
    5 hp @ 460V AC
    5 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K91300000
    4208, 2401050653 hp @ 115V AC
    10 hp @ 230V AC
    15 hp @ 230V AC
    30 hp @ 460V AC
    30 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K776000000
    4208, 24019901207 1/2 hp @ 115V AC
    20 hp @ 230V AC
    30 hp @ 230V AC
    50 hp @ 460V AC
    50 hp @ 575V AC
    5"3.7"4.4"0.25"6564K796000000
    4208, 24050.460755 hp @ 115V AC
    10 hp @ 230V AC
    20 hp @ 230V AC
    40 hp @ 460V AC
    40 hp @ 575V AC
    3.8"2.6"4"0.25"6564K786000000
    4208, 24050.475905 hp @ 115V AC
    15 hp @ 230V AC
    20 hp @ 230V AC
    50 hp @ 460V AC
    50 hp @ 575V AC
    3.8"2.6"4"0.25"6564K873000000
     
    3 Circuits Controlled with 3 Off—3PST-NO
     
    Screw Terminal
    6208, 24049.81201407.2"4.1"5.9"6564K89300000000
     
    Quick-Disconnect × Screw Terminal
    6208, 240715203/4 hp @ 115V AC
    2 hp @ 230V AC
    3 hp @ 230V AC
    5 hp @ 460V AC
    5 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K923000000
    6208, 240725352 hp @ 115V AC
    3 hp @ 230V AC
    7 1/2 hp @ 230V AC
    10 hp @ 460V AC
    10 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K933000000
    6208, 240730402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K943000000
    6208, 240740503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K953000000
    6208, 2401050653 hp @ 115V AC
    10 hp @ 230V AC
    15 hp @ 230V AC
    30 hp @ 460V AC
    30 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K963000000
    6208, 24019901207 1/2 hp @ 115V AC
    20 hp @ 230V AC
    30 hp @ 230V AC
    50 hp @ 460V AC
    50 hp @ 575V AC
    5"3.7"4.4"0.25"6564K989000000
    6208, 24050.460755 hp @ 115V AC
    10 hp @ 230V AC
    20 hp @ 230V AC
    40 hp @ 460V AC
    40 hp @ 575V AC
    3.8"2.6"4"0.25"6564K973000000
    6208, 24050.475905 hp @ 115V AC
    15 hp @ 230V AC
    20 hp @ 230V AC
    50 hp @ 460V AC
    50 hp @ 575V AC
    3.8"2.6"4"0.25"6564K883000000
     
    4 Circuits Controlled with 4 Off—4PST-NO
     
    Quick-Disconnect × Screw Terminal
    8208, 24050.425352 hp @ 115V AC
    3 hp @ 230V AC
    7 1/2 hp @ 230V AC
    10 hp @ 460V AC
    10 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K103000000
    8208, 24050.430402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K203000000
    8208, 24050.440503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K303000000
     
    Enclosures

    Washdown Enclosed Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Washdown Enclosed Relays.
    A NEMA 4X enclosure protects these relays from washdowns, dirt, and corrosion. It also keeps terminals from being bumped accidentally, so you can mount these relays near working areas. Hardwire to your equipment with the wire leads.
    Wire
    Lead
    Conduit
    Connection
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching
    Voltage
    Ht.
    Wd.
    Dp.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    12V AC, 24V AC, 208V AC, 240V AC, 277V AC, 12V DC, 24V DC, 30V DC3910 amp @ 277V AC2771/3 hp @ 240V AC1.7"2.8"1.5"16"6Male1/2
    NPT
    4766T12000000
    24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC4010 amp @ 277V AC2771/2 hp @ 120V AC1.7"2.8"1.5"16"6Male1/2
    NPT
    4766T1600000
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    24V AC, 208V AC, 240V AC, 277V AC, 24V DC3610 amp @ 277V AC2771/2 hp @ 240V AC1.7"2.8"1.5"16"9Male1/2
    NPT
    4766T1400000
     

    Wireless Enclosed Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Wireless Enclosed Relays.
    Send a signal to turn equipment on and off from up to 150 feet away without having to run electrical wire. These relays have an enclosure to protect the terminals from dust and accidental bumps. They can be set to transmit, receive, or both at once. You’ll need at least two relays to switch a device. They have an alarm that can be set to check for certain conditions before transmitting a signal. For example, you could set these relays to send a signal to turn on an air conditioner if all windows are closed. The repeat function extends the transmitting signal through a maximum of two receiving relays.
    Relays that are set to transmit can be linked up to as many receiving relays as you need. Relays set to receive can be linked up to 30 transmitting relays. All relays connect to dry contacts on your switch, sensor, or controller. Use the wire leads to connect them to a power source.
    UL and C-UL listed, all meet American and Canadian safety standards. Rated NEMA 1, they should only be used indoors.
    Wire
    Lead
    Conduit
    Connection
    Input Voltage,
    V AC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching
    Voltage
    Ht.
    Wd.
    Dp.
    Max. Transmission
    Distance, ft.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Enclosure
    Rating
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Conduit-Hub Mount/Surface Mount
    2088020 amp @ 277V AC2772 hp @ 277V AC2.3"3.2"1.8"15016"7Male1/2
    NPT
    NEMA 1
    Alarm, Repeat Function3918N120000000
     

    Enclosed Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Heavy Duty Motor Starters.
    Housed in a durable steel enclosure, these starters have sealed coils for protection against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Tripping
    Accuracy
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
     
    NEMA Contact Size 0
    0.25 to 1208Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K34300000007463K7130000000
    0.75 to 3.4208Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3530000007463K713000000
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4230000007463K713000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4330000007463K713000000
     
    NEMA Contact Size 1
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4530000007463K713000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4630000007463K713000000
    10 to 40208Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4730000007463K713000000
     
    NEMA Contact Size 2
    13 to 52208Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K523000000007463K713000000
     

    Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Heavy Duty Motor Starters.
    Sealed coils protect these starters against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Tripping
    Accuracy
    Ht.
    Wd.
    Certification
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
     
    NEMA Contact Size 0
    0.25 to 1208Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K32300000007463K7130000000
    0.75 to 3.4208Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K3330000007463K713000000
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1230000007463K713000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1330000007463K713000000
     
    NEMA Contact Size 1
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1530000007463K713000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1630000007463K713000000
    10 to 40208Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1730000007463K713000000
     
    NEMA Contact Size 2
    13 to 52208Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%8.1"4.6"UL Listed, CSA Certified
    7463K2230000007463K713000000
     