    90 Products

    Smart Multifunction Monitoring Relays

    Image of ProductInUse. Front orientation. Monitoring Relays. Smart Multifunction Monitoring Relays.
    Remotely control these relays through an app on your smartphone—they simultaneously monitor phase, voltage, and frequency. The downloadable app lets you change the tripping range, modify settings, and save programs to apply to multiple relays. Tap your smartphone or tablet to the relays to connect to them. They use NFC (near field communication), so you don’t need to manually pair them like Bluetooth devices.
    You’ll often see these relays used to protect motors, generators, and other three-phase circuits from burning out or overheating. They'll switch the circuit off if they detect voltage or frequencies outside of the set range or phase loss, imbalance, or reversal. You can see that they're wired correctly and when they're actuated based on the LED indicators. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    No. of
    Terminals
    Input Voltage, V AC
    Trip Voltage,
    V AC
    Input Freq.,
    Hz
    Trip Freq.,
    Hz
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Operating System Compatibility
    Each
    2 Circuits Controlled with 2 Off or 2 On—DPDT
     
    With Screw Terminals
    12208, 240, 300, 480208 to 48050, 6045 to 660.1 to 60Automatic8 amp @ 240V AC2503.5"0.9"3.9"Android 7.0 or Later, iOS 14.5 or Later8452N110000000
     

    Motor Starters

    Image of Product. Front orientation. Motor Starters. Motor Starters .
    Provide on/off control for a motor and protect it from overloads. These starters shut off the motor if current exceeds the full-load current rating. All have an adjustable overload relay that allows you to set the exact overload current you need.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
    Auxiliary Contact Switch Starting Position—Starters with auxiliary contacts can send a signal or connect to another device, such as an alarm or indicating light.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1 to 5480Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K14600000007603K2960000007603K297000000
    1.1 to 1.6480Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K1840000007603K8000007603K900000
    1.8 to 2.5480Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K1940000007603K8000007603K900000
    2.3 to 3.2480Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2140000007603K8000007603K900000
    3.5 to 4.8480Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2240000007603K8000007603K900000
    4 to 20480Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1570000007603K296000007603K29700000
    5.5 to 7.5480Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2340000007603K8000007603K900000
    9 to 12.5480Single (1/2 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2440000007603K8000007603K900000
    11.3 to 16480Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2640000007603K8000007603K900000
    20 to 100480Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K1790000007603K298000007603K29900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    17.5 to 21.5480Single (1 1/2 hp @ 115V AC)
    Single (3 hp @ 230V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (15 hp @ 480V AC)
    4.9"2.2"DIN Rail357603K2740000007603K8000007603K900000
    24.5 to 30480Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    4.9"2.2"DIN Rail357603K2840000007603K8000007603K900000
    24.5 to 36480Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (25 hp @ 480V AC)
    5.9"2.7"DIN Rail357603K2940000007603K8000007603K900000
    35 to 47480Single (7 1/2 hp @ 230V AC)
    Three (15 hp @ 230V AC)
    Three (30 hp @ 480V AC)
    5.9"2.7"DIN Rail357603K1140000007603K8000007603K900000
     
    Motor Starters with 4 Auxiliary Contacts—2 Off, 2 On
    45 to 60480Single (5 hp @ 115V AC)
    Single (10 hp @ 230V AC)
    Three (20 hp @ 230V AC)
    Three (40 hp @ 480V AC)
    6.7"3.7"DIN Rail357603K3040000007603K8000007603K900000
    58 to 75480Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    6.7"3.7"DIN Rail357603K9440000007603K8000007603K900000
     

    Low-Profile Motor Starters

    Image of Product. Front orientation. Motor Starters. Low-Profile Motor Starters.
    With a shallower depth than most other starters, these fit in narrow spaces. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1.1 to 1.6480Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K13400000007603K60000007603K7000000
    1.8 to 2.5480Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K1440000007603K6000007603K700000
    2.3 to 3.2480Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K1540000007603K6000007603K700000
    3.5 to 4.8480Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K1640000007603K6000007603K700000
    5.5 to 7.5480Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    4.2"1.8"DIN Rail357603K1740000007603K6000007603K700000
     

    Enclosed Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Motor Starters.
    The NEMA 4X rated enclosure protects these starters from corrosion and washdowns. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1 to 5480Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K18800000007603K2960000007603K297000000
    1.1 to 1.6480Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3740000007603K8000007603K900000
    1.8 to 2.5480Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3940000007603K8000007603K900000
    2.3 to 3.2480Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4140000007603K8000007603K900000
    3.5 to 4.8480Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4240000007603K8000007603K900000
    4 to 20480Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1990000007603K296000007603K29700000
    5.5 to 7.5480Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K5140000007603K8000007603K900000
    9 to 12.5480Single (1/2 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K5240000007603K8000007603K900000
    9 to 45480Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2660000007603K296000007603K29700000
    11.3 to 16480Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4640000007603K8000007603K900000
    17.5 to 21.5480Single (1 1/2 hp @ 115V AC)
    Single (3 hp @ 230V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (15 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4740000007603K8000007603K900000
    24.5 to 30480Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4840000007603K8000007603K900000
    24.5 to 36480Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (25 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4940000007603K8000007603K900000
    35 to 47480Single (7 1/2 hp @ 230V AC)
    Three (15 hp @ 230V AC)
    Three (30 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K1240000007603K8000007603K900000
    45 to 60480Single (5 hp @ 115V AC)
    Single (10 hp @ 230V AC)
    Three (20 hp @ 230V AC)
    Three (40 hp @ 480V AC)
    11.8"8.7"NEMA 4X, IP55
    UL Recognized Component
    7603K9340000007603K8000007603K900000
    58 to 75480Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.8"8.7"NEMA 4X, IP55
    UL Recognized Component
    7603K9640000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    20 to 100480Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.7"9.3"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K277000000007603K298000007603K29900000
     

    Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Heavy Duty Motor Starters.
    Sealed coils protect these starters against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Tripping
    Accuracy
    Ht.
    Wd.
    Certification
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
     
    NEMA Contact Size 0
    0.25 to 1220/480Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K32400000007463K7140000000
    0.75 to 3.4220/480Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K3340000007463K714000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1240000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1340000007463K714000000
     
    NEMA Contact Size 1
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1540000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1640000007463K714000000
    10 to 40220/480Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%7.4"4.3"UL Listed, CSA Certified
    7463K1740000007463K714000000
     
    NEMA Contact Size 2
    13 to 52220/480Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%8.1"4.6"UL Listed, CSA Certified
    7463K2240000007463K714000000
     

    Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Reversing Motor Starters .
    Use these starters with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 On
    1.1 to 1.6480Three (1/3 hp @ 230V AC)
    Three (3/4 hp @ 480V AC)
    4.7"4"DIN Rail357636K21400000007603K80000007603K9000000
    1.8 to 2.5480Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    4.7"4"DIN Rail357636K2240000007603K8000007603K900000
    2.3 to 3.2480Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 480V AC)
    4.7"4"DIN Rail357636K2340000007603K8000007603K900000
    3.5 to 4.8480Three (1 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    4.7"4"DIN Rail357636K2440000007603K8000007603K900000
    5.5 to 7.5480Three (2 hp @ 230V AC)4.7"4"DIN Rail357636K2540000007603K8000007603K900000
    9 to 12.5480Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    4.7"4"DIN Rail357636K2640000007603K8000007603K900000
    11.3 to 16480Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    4.7"4"DIN Rail357636K2840000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    17.5 to 21.5480Three (15 hp @ 480V AC)4.9"4.7"DIN Rail357636K2940000007603K8000007603K900000
    20 to 100480Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K219000000007603K298000007603K29900000
     
    Motor Starters with 3 Auxiliary Contacts—2 Off, 1 On
    1 to 5480Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1760000007603K296000007603K29700000
    4 to 20480Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1870000007603K296000007603K29700000
    9 to 45480Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K198000000007603K296000007603K29700000
     

    Compact Enclosed Motor Starters

    Image of Product. Front orientation. Motor Starters. Compact Enclosed Motor Starters.
    Sized to fit in tight spaces, these starters have a shorter height and narrower depth than most other starters. A NEMA 4X rated enclosure protects them from corrosion and washdowns. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1.1 to 1.6480Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K31400000007603K60000007603K7000000
    1.8 to 2.5480Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3240000007603K6000007603K700000
    2.3 to 3.2480Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3340000007603K6000007603K700000
    3.5 to 4.8480Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3440000007603K6000007603K700000
    5.5 to 7.5480Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3540000007603K6000007603K700000
     

    Enclosed Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Heavy Duty Motor Starters.
    Housed in a durable steel enclosure, these starters have sealed coils for protection against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Tripping
    Accuracy
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
     
    NEMA Contact Size 0
    0.75 to 3.4220/480Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K35400000007463K7140000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4240000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4340000007463K714000000
     
    NEMA Contact Size 1
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4540000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4640000007463K714000000
    10 to 40220/480Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4740000007463K714000000
     
    NEMA Contact Size 2
    13 to 52220/480Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K524000000007463K714000000
     

    Enclosed Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Reversing Motor Starters.
    Rated NEMA 4X, these enclosed starters are protected from corrosion and washdowns. Use them with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 On
    1.1 to 1.6480Three (1/3 hp @ 230V AC)
    Three (3/4 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K31400000007603K80000007603K9000000
    1.8 to 2.5480Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3240000007603K8000007603K900000
    2.3 to 3.2480Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3340000007603K8000007603K900000
    3.5 to 4.8480Three (1 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3440000007603K8000007603K900000
    5.5 to 7.5480Three (2 hp @ 230V AC)8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3540000007603K8000007603K900000
    9 to 12.5480Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3640000007603K8000007603K900000
    11.3 to 16480Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3840000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    17.5 to 21.5480Three (15 hp @ 480V AC)11.8"8.7"NEMA 4X, IP55
    UL Recognized Component
    7636K3940000007603K8000007603K900000
     
    Motor Starters with 3 Auxiliary Contacts—2 Off, 1 On
    1 to 5480Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2280000007603K296000007603K29700000
    4 to 20480Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2390000007603K296000007603K29700000
     