Filter by
Input Voltage
Switching Voltage
Switching Current
Mounting Location
Timer Function
Operation Type
Overall Timing
Switch Starting Position
Timing Adjustment Style
Horsepower @ Switching Voltage
DFARS Specialty Metals
Export Control Classification Number (ECCN)
DIN-Rail Mount Solid State Relays
No. of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage (Load Type) | Max. Switching Voltage, V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 Circuit Controlled with 1 Off—SPST-NO | |||||||||||||
Single Phase | |||||||||||||
| 4 | 24V AC, 90V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 275V AC | 12 | 5 amp @ 24V AC (Full) 10 amp @ 24V AC (Resistive) 10 amp @ 240V AC | 240 | — | 4.173" | 0.7" | 2.56" | Integrated Heat Sink, LED Indicator | 8299K34 | 000000 | ||
| 4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 13 | 20 amp @ 240V AC (Full) | 264 | 1/3 hp @ 115V AC 1 hp @ 230V AC | 4.33" | 0.7" | 3.447" | Integrated Heat Sink, LED Indicator | 4398N12 | 00000 | ||
| 4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 13 | 20 amp @ 600V AC (Full) | 660 | 1/3 hp @ 115V AC 1 hp @ 230V AC | 4.33" | 0.7" | 3.447" | Integrated Heat Sink, LED Indicator | 6323T41 | 00000 | ||
| 4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 13 | 30 amp @ 230V AC (Full) | 264 | 3/4 hp @ 115V AC 2 hp @ 230V AC | 4.33" | 0.89" | 4.917" | Integrated Heat Sink, LED Indicator | 7456K78 | 000000 | ||
| 4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 13 | 85 amp @ 600V AC (Full) | 660 | 2 hp @ 115V AC 5 hp @ 230V AC | 5.12" | 2.76" | 5.247" | Integrated Heat Sink, Integrated Fan, LED Indicator | 6323T81 | 000000 | ||
| 4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 22 | 30 amp @ 600V AC (Full) | 660 | 3/4 hp @ 115V AC 2 hp @ 230V AC | 4.33" | 0.89" | 4.917" | Integrated Heat Sink, LED Indicator | 6323T32 | 000000 | ||
| 4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 22 | 40 amp @ 600V AC (Full) | 660 | 1 hp @ 115V AC 3 hp @ 230V AC | 4.33" | 1.4" | 4.917" | Integrated Heat Sink, LED Indicator | 6323T34 | 000000 | ||
2 Circuits Controlled with 2 Off—DPST-NO | |||||||||||||
Three Phase | |||||||||||||
| 8 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 amp @ 220V AC (Full) | 242 | 1 1/2 hp @ 115V AC 3 hp @ 230V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 7456K81 | 000000 | ||
| 8 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 amp @ 600V AC (Full) | 660 | 5 hp @ 230V AC 10 hp @ 480V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 7456K82 | 000000 | ||
| 8 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 40 amp @ 600V AC (Full) | 660 | 5 hp @ 230V AC 10 hp @ 480V AC | 4.33" | 2.84" | 4.66" | Integrated Heat Sink, LED Indicator | 6323T83 | 000000 | ||
| 15 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 75 amp @ 600V AC (Full) | 660 | 10 hp @ 230V AC 20 hp @ 480V AC | 5.55" | 2.84" | 4.679" | Integrated Heat Sink, Integrated Fan, LED Indicator | 6323T85 | 000000 | ||
3 Circuits Controlled with 3 Off—3PST-NO | |||||||||||||
Three Phase | |||||||||||||
| 8 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 20 amp @ 600V AC (Full) | 660 | 3 hp @ 230V AC 7 1/2 hp @ 480V AC | 4.33" | 2.1" | 3.427" | Integrated Heat Sink, LED Indicator | 6323T71 | 000000 | ||
| 8 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 30 amp @ 600V AC (Full) | 660 | 5 hp @ 230V AC 10 hp @ 480V AC | 4.33" | 2.84" | 4.66" | Integrated Heat Sink, LED Indicator | 6323T87 | 000000 | ||
| 15 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 40 amp @ 600V AC (Full) | 660 | 5 hp @ 230V AC 10 hp @ 480V AC | 5.31" | 2.13" | 3.739" | Integrated Heat Sink, Integrated Fan, LED Indicator | 6323T89 | 000000 | ||
| 15 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 65 amp @ 600V AC (Full) | 660 | 10 hp @ 230V AC 20 hp @ 480V AC | 5.55" | 2.84" | 4.679" | Integrated Heat Sink, Integrated Fan, LED Indicator | 6323T92 | 000000 | ||
DIN-Rail Mount Multifunction Timer Relays
Timer Relays with Delayed, Interval, Switch On, and Repeat Cycles
Timing Range | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Each | |||
1 Circuit Controlled with 1 Off or 1 On—SPDT | ||||||||||||||
| 6 | 12V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 7 | Delayed Start (Delay on Make) Delayed Switch Off (Delay on Break) Delayed Switch-On with Delayed Switch-Off Interval Switch on (Single Shot) Repeat Cycle | 6 | 0.1 sec. to 24 hr. | 16 amp @ 240V AC | 250 | 3.5" | 0.7" | 2.4" | 6964K4 | 000000 | ||
| 8 | 12V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 6 | Delayed Start (Delay on Make) Delayed Switch Off (Delay on Break) Delayed Switch-On with Delayed Switch-Off Delayed Pulse Interval Interval Switch-Off Switch on (Single Shot) Repeat Cycle Start-Off Repeat Cycle Switch Fixed On/Off | 8 | 0.1 sec. to 10 day | 8 amp @ 240V AC | 250 | 4.1" | 0.7" | 2.6" | 6964K102 | 00000 | ||
2 Circuits Controlled with 2 Off or 2 On—DPDT | ||||||||||||||
| 8 | 12V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 7 | Delayed Start (Delay on Make) Delayed Switch Off (Delay on Break) Delayed Switch-On with Delayed Switch-Off Delayed Pulse Interval Interval Switch-Off Switch on (Single Shot) Repeat Cycle Start-Off Repeat Cycle Switch Fixed On/Off | 8 | 0.1 sec. to 10 day | 8 amp @ 240V AC | 250 | 4.1" | 0.7" | 2.6" | 6964K103 | 000000 | ||
Timer Relays with Asymmetrical Repeat Cycles
Timing Range | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Each | |||
1 Circuit Controlled with 1 Off or 1 On—SPDT | ||||||||||||||
| 6 | 12V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 7 | Asymmetrical Repeat Cycle Switch-On Asymmetrical Repeat Cycle | 6 | 0.1 sec. to 24 hr. | 16 amp @ 240V AC | 250 | 3.5" | 0.7" | 2.4" | 6964K17 | 000000 | ||
| 8 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 6.2 | Asymmetrical Repeat Cycle Start-Off Asymmetrical Repeat Cycle Switch-On Asymmetrical Repeat Cycle Switch-Off Asymmetrical Repeat Cycle | 8 | 0.05 sec. to 10 day | 16 amp @ 240V AC | 250 | 3.4" | 0.9" | 3.9" | 6964K101 | 00000 | ||
Solid State Screw Terminal Relays
Relays | Heat Sinks | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | ||||||||||||||
No. of Terminals | Input Voltage | Without Heat Sink | With Heat Sink, amp | Max. Switching Voltage | Ht. | Wd. | Dp. | Enclosure Rating | Each | Each | ||||
1 Circuit Controlled with 1 Off—SPST-NO | ||||||||||||||
Relays | ||||||||||||||
| 4 | 5V DC, 6V DC, 12V DC, 24V DC, 48V DC, 60V DC | 2 amp @ 60V DC | 3 | 60V DC | 2.3" | 1.8" | 0.8" | — | 7456K71 | 000000 | 7456K73 | 0000000 | ||
| 4 | 5V DC, 6V DC, 12V DC, 24V DC, 48V DC, 60V DC | 2 amp @ 60V DC | 5 | 60V DC | 2.3" | 1.8" | 1" | — | 7456K72 | 00000 | 7456K73 | 000000 | ||
Relays with High-Starting-Current Protection and Covered Terminals | ||||||||||||||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 2.5 amp @ 240V AC | 25 | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K62 | 00000 | 7456K221 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 2.5 amp @ 480V AC | 25 | 530V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K106 | 00000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 2.5 amp @ 600V AC | 25 | 660V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K115 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 5 amp @ 240V AC | 50 | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K64 | 00000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 5 amp @ 480V AC | 50 | 530V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K108 | 00000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 5 amp @ 600V AC | 50 | 660V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K117 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 7.5 amp @ 240V AC | 75 | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K102 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 7.5 amp @ 480V AC | 75 | 530V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K111 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 7.5 amp @ 600V AC | 75 | 660V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K119 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 10 amp @ 240V AC | 100 | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K104 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 10 amp @ 480V AC | 100 | 530V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K113 | 000000 | 7456K33 | 00000 | ||
| 4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 10 amp @ 600V AC | 100 | 660V AC | 2.3" | 1.8" | 1.1" | IP20 | 7456K122 | 000000 | 7456K33 | 00000 | ||
DIN-Rail Mount Interface Relays
1 Circuit Controlled with 1 Off or 1 On—SPDT
Interface Relays | Replacement Relays | Fuse Holders | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Features | Each | Each | Each | |||||
With Screw Terminals | ||||||||||||||||
| 5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6 amp @ 240V AC | 250 | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 4144N105 | 000000 | 8262T21 | 00000 | 4144N108 | 00000 | ||
With Spring-Clamp Terminals | ||||||||||||||||
| 5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6 amp @ 240V AC | 250 | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 4144N106 | 00000 | 8262T21 | 0000 | 4144N108 | 0000 | ||
Solid State DIN-Rail Mount Timer Relays
Timing Range | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Each | |||
Delayed Start (Delay on Make) | |||||||||||||
1 Circuit Controlled with 1 Off—SPST-NO | |||||||||||||
| 6 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 7 | 7 | 0.1 sec. to 100 hr. | 0.7 amp @ 240V AC | 250 | 3 1/2" | 0.7" | 2.7" | 7801K51 | 000000 | ||
DIN-Rail Mount Solid State Interface Relays
1 Circuit Controlled with 1 Off—SPST-NO
Interface Relays | Replacement Relays | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Output Voltage, V DC | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage, V DC | Ht. | Wd. | Dp. | Features | Each | Each | ||||
With Screw Terminals | |||||||||||||||
| 5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 0 to 48 | 22 | 100 mA @ 48V DC | 48 | 3.5" | 0.2" | 3.4" | LED Power Indicator | 7356K25 | 000000 | 4026N14 | 000000 | ||
| 5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | — | 18 | 5 amp @ 30V DC | 33 | 3.5" | 0.5" | 3.4" | LED Power Indicator | 8299K15 | 00000 | 4026N16 | 00000 | ||
High-Starting-Current DIN-Rail Mount Timer Relays
Timing Range | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Each | |||
2 Circuits Controlled with 2 Off—DPST-NO | ||||||||||||||
| 5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 30V DC, 48V DC, 60V DC, 120V DC, 240V DC | 5 | Star-to-Delta | 6 | 0.1 sec. to 20 min. | 6 amp @ 12V AC to 250V AC, 240V AC | 250 | 3.4" | 0.7" | 2.4" | 8474N11 | 000000 | ||
Smart DIN-Rail Mount Multifunction Timer Relays
![]() | ![]() |
1 Circuit Controlled | 2 Circuits Controlled |
No. of Terminals | Input Voltage | Control Power, W | Timer Relay Function | Overall Timing Range | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Operating System Compatibility | Features | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||||
| 8 | 12V AC, 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 0.15 | Manual Switch Control Fixed On/Off Switch on (Single Shot) Delayed Start (Delay on Make) Delayed Switch Off (Delay on Break) Delayed Switch-On with Delayed Switch-Off Interval Repeat Cycle Asymmetrical Repeat Cycle Switch-On Asymmetrical Repeat Cycle | 0.1 sec. to 999 day | 8 amp @ 240V AC | 250 | 4.1" | 0.7" | 2.5" | Android 5.0 or Later, iOS 14.4 or Later | LED Indicator | 8491N12 | 000000 | ||
2 Circuits Controlled with 2 Off or 2 On—DPDT | |||||||||||||||
| 9 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 0.6 | Manual Switch Control Fixed On/Off Switch on (Single Shot) Delayed Start (Delay on Make) Delayed Switch Off (Delay on Break) Delayed Switch-On with Delayed Switch-Off Interval Repeat Cycle Asymmetrical Repeat Cycle Switch-On Asymmetrical Repeat Cycle Star-to-Delta | 0.1 sec. to 999 hr. | 8 amp @ 240V AC | 250 | 3.5" | 0.9" | 2.9" | Android 4.4 or Later, iOS 14.5 or Later | LED Indicator | 8491N11 | 000000 | ||
Solid State DIN-Rail Mount Multifunction Timer Relays
![]() | ![]() | ![]() | ![]() |
Relays with 1 Circuit Controlled, DIP Switches, and Quick-Disconnect Terminals | Relays with 1 Circuit Controlled, DIP Switches, and Screw Terminals | Relays with 1 Circuit Controlled, Knob, and Quick-Disconnect Terminals | Relays with 1 Circuit Controlled, Knob, and Screw Terminals |
Timing Range | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage, V DC | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Wire Connection | Each | |||
Timing-Adjustment DIP Switch | |||||||||||||||
1 Circuit Controlled with 1 Off—SPST-NO | |||||||||||||||
| 4 | 9, 12, 24, 48, 60, 110 | 8 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 4 | 0.1 sec. to 63 min. | 0.7 amp @ 240V AC | 240 | 3" | 0.7" | 2.4" | Quick-Disconnect Terminal | 7399K26 | 0000000 | ||
| 6 | 9, 12, 24, 48, 60, 110 | 8 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 4 | 0.1 sec. to 63 min. | 0.7 amp @ 240V AC | 240 | 3" | 0.7" | 2.4" | Screw Terminal | 7399K28 | 000000 | ||
Timing-Adjustment Knob | |||||||||||||||
1 Circuit Controlled with 1 Off—SPST-NO | |||||||||||||||
| 4 | 9, 12, 24, 48, 60, 110 | 8 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 4 | 0.1 sec. to 100 min. | 0.7 amp @ 240V AC | 240 | 3" | 0.7" | 2.4" | Quick-Disconnect Terminal | 7399K22 | 000000 | ||
| 6 | 9, 12, 24, 48, 60, 110 | 8 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 4 | 0.1 sec. to 100 min. | 0.7 amp @ 240V AC | 240 | 3" | 0.7" | 2.4" | Screw Terminal | 7399K24 | 000000 | ||
Solid State Versa-Mount Multifunction Timer Relays
Timer Relays | Sockets | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | |||||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Ht. | Wd. | Dp. | Each | Each | ||||
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||||
| 11 | 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 17 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 7 | 0.1 sec. to 999 hr. | 3 amp @ 240V AC | 1.9" | 1.9" | 2.7" | 6963K14 | 0000000 | 7122K21 | 00000 | ||
Thin Spade-Terminal Relays
Relays | Sockets with Screw Terminals | Sockets with Spring-Clamp Terminals | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage, V DC | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage, V AC | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||||
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||||||
Relay-Socket Mount | |||||||||||||||||
| 5 | 48 | 11 | 10 amp @ 120V AC/24V DC | 380 | 1/3 hp @ 120V AC | 1.1" | 0.5" | 1.4" | 0.187" | 7098K68 | 00000 | 7098K21 | 00000 | 7098K23 | 00000 | ||
Safety Relays with Diagnostic Capabilities
No. of Terminals | Input Voltage | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | For Use With | Mounting Location | Max. System Safety Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 Circuits Controlled | |||||||||||||
3 Safety Outputs with 2 Off and 1 Signal Output with 2 On | |||||||||||||
| 24 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 5 amp @ 240V AC 5 amp @ 24V DC | 250V AC, 250V DC | 4.42" | 0.9" | 4.5" | Emergency Stops | DIN Rail | PLe, SIL 3 | 6322N14 | 000000000 | ||
Hazardous Location Relays
No. of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Enclosure Rating | Hazardous Location Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Screw Terminals | |||||||||||||
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||
| 5 | 48V AC, 48V DC | 4 | 6 amp @ 240V AC/30V DC | 400V AC/125V DC | 3.5" | 0.2" | 2.9" | IP20 | NEC Class I Division 2 Groups A, B, C, D | 4190N12 | 000000 | ||
| 5 | 48V AC, 48V DC | 4 | 16 amp @ 240V AC/24V DC | 400V AC/300V DC | 3.5" | 0.6" | 2.9" | IP20 | NEC Class I Division 2 Groups A, B, C, D | 4190N17 | 00000 | ||
2 Circuits Controlled with 2 Off or 2 On—DPDT | |||||||||||||
| 8 | 48V AC, 48V DC | 4 | 8 amp @ 240V AC/24V DC | 400V AC/300V DC | 3.5" | 0.6" | 2.9" | IP20 | NEC Class I Division 2 Groups A, B, C, D | 4190N18 | 00000 | ||
Multifunction Timer Relays
Timer Relays | Sockets | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | ||||||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Each | Each | ||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | ||||||||||||||||
Relay-Socket/Panel Mount | ||||||||||||||||
| 11 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 104 | Delayed Start (Delay on Make) Interval Switch on (Single Shot) Delayed Switch Off (Delay on Break) Repeat Cycle | 6 | 0.05 sec. to 999 hr. | 10 amp @ 240V AC | 240 | 1.9" | 1.9" | 2.8" | 6964K3 | 0000000 | 7122K21 | 00000 | ||
Solid State Versa-Mount Timer Relays
Timer Relays | Sockets | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | ||||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ Voltage | Ht. | Wd. | Dp. | Each | Each | ||||
Asymmetrical Repeat Cycle | ||||||||||||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | ||||||||||||||
| 8 | 24V AC, 48V AC, 12V DC, 24V DC, 48V DC | 83 | 4 | 0.05 sec. to 300 hr. | 5 amp @ 240V AC | 1.9" | 1.9" | 3.3" | 69695K114 | 0000000 | 7122K19 | 00000 | ||
| 11 | 24V AC, 48V AC, 12V DC, 24V DC, 48V DC | 83 | 4 | 0.05 sec. to 300 hr. | 5 amp @ 240V AC | 1.9" | 1.9" | 3.3" | 8934N14 | 000000 | 7122K21 | 0000 | ||
Start-Off Asymmetrical Repeat Cycle | ||||||||||||||
2 Circuits Controlled with 2 Off or 2 On—DPDT | ||||||||||||||
| 8 | 24V AC, 48V AC, 12V DC, 24V DC, 48V DC | 83 | 4 | 0.05 sec. to 300 hr. | 5 amp @ 240V AC | 1.9" | 1.9" | 3.3" | 69695K112 | 000000 | 7122K19 | 0000 | ||
| 11 | 24V AC, 48V AC, 12V DC, 24V DC, 48V DC | 83 | 4 | 0.05 sec. to 300 hr. | 5 amp @ 240V AC | 1.9" | 1.9" | 3.3" | 8934N12 | 000000 | 7122K21 | 0000 | ||