Spade-Terminal Relays
Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface mount relays, also known as power relays, have a slot on the flange for mounting them to flat surfaces.
Relay-socket mount relays, also known as ice cube relays, offer three ways to connect. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals.
Relay-socket/surface mount relays can plug into a socket or mount to a flat surface.
Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They can also mount to a flat surface.

Number of Terminals | Input Voltage | Control Current, mA | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
6 | 12V DC | 158 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 000000 |
6 | 24V AC | 71 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 24V DC | 79 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 120V AC | 20 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 240V AC | 10 | 250V AC | 1 1/2 hp @ 120 V AC 2 hp @ 240 V AC 2 hp @ 277 V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
DIN-Rail Mount Solid State Relays

Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, switch faster, and are quieter. They mount on 35 mm DIN rail (also known as DIN 3) for fast installation. An LED indicator lights up when these relays are connected, so you can quickly confirm that they’re wired correctly. IP20 rated, their terminals are recessed, so they prevent fingers and other objects from touching live circuits.
Relays with an integrated heat sink disperse heat to increase the relay’s current rating.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Two Phase | |||||||||||
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 A @ 220 V AC (Full Load) | 242V AC | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 0000000 |
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 25 A @ 220 V AC (Full Load) | 242V AC | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 25 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.33" | 2.13" | 3.427" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
DIN-Rail Mount Touch-Safe Screw Terminal Relays
Quickly and safely mount these relays on 35 mm DIN rail (also known as DIN 3). IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits.
Relays that control 3 and 4 circuits are built to IEC dimensional standards and are often called IEC contactors. Those with 12 terminals let you attach the control circuit onto the side that works best for your setup, which reduces the amount of wire you need.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay. You can add one auxiliary contact to all of these relays. For relays with 12 terminals, you can add two side-mount auxiliary contacts.
Use replacement coils to swap out a broken coil or change the input voltage of a relay. They are only compatible with relays that have 12 terminals. The full load current of the relay must match the full load current range of the coil.
For technical drawings and 3-D models, click on a part number.

Control | hp @ Switching Voltage | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Power | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
6 | 24V AC, 24V DC | 2VA | 25 A @ 240 V AC (Resistive Load) | 240 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | __ | 3.5" | 0.7" | 2.4" | 0000000 | 000000 |
6 | 120V AC, 120V DC | 2VA | 25 A @ 240 V AC (Resistive Load) | 240 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | __ | 3.5" | 0.7" | 2.4" | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | |||||||||||
12 | 24V AC | 6.5VA | 9 A @ 600 V AC (Full Load) 25 A @ 600 V AC (Resistive Load) | 600 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 9 A @ 600 V AC (Full Load) 25 A @ 600 V AC (Resistive Load) | 600 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 9 A @ 600 V AC (Full Load) 25 A @ 600 V AC (Resistive Load) | 600 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 24V DC | 5.4W | 9 A @ 600 V AC (Full Load) 25 A @ 600 V AC (Resistive Load) | 600 V AC | 3/4 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |


Number of Circuits Controlled | For Relay Width | Switch Starting Position | Industry Designation | Mounting Location | Each | |
2 | 0.7" | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-1NO/1NC | Side | 0000000 | 000000 |
2 | 0.7" | 2 Off (Normally Open) | DPST-NO | Side | 0000000 | 00000 |
2 | 1.8", 2.4" | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-1NO/1NC | Front | 00000000 | 00000 |
2 | 1.8", 2.4" | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-1NO/1NC | Side | 00000000 | 00000 |
2 | 1.8", 2.4" | 2 Off (Normally Open) | DPST-NO | Front | 0000000 | 00000 |
2 | 1.8", 2.4" | 2 On (Normally Closed) | DPST-NC | Front | 0000000 | 00000 |
4 | 1.8", 2.4" | 1 Off (Normally Open) and 3 On (Normally Closed) | 4PST-1NO/3NC | Front | 0000000 | 00000 |
4 | 1.8", 2.4" | 2 Off (Normally Open) and 2 On (Normally Closed) | 4PST-2NO/2NC | Front | 0000000 | 00000 |
4 | 1.8", 2.4" | 3 Off (Normally Open) and 1 On (Normally Closed) | 4PST-3NO/1NC | Front | 0000000 | 00000 |
4 | 1.8", 2.4" | 4 Off (Normally Open) | 4PST-NO | Front | 0000000 | 00000 |
4 | 1.8", 2.4" | 4 On (Normally Closed) | 4PST-NC | Front | 0000000 | 00000 |
Screw Terminal Relays


Use the screw terminals to hardwire these relays. The built-in enclosure protects contacts from dust and dirt. These relays accept voltage drops up to 50% of the rated voltage without switching. They’re often used with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Switching Current @ Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | |
4 Circuits Controlled with 2 Off (Normally Open) and 2 On (Normally Closed)—4PST-2NO/2NC | |||||||||||
10 | 120V AC | 22 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 000000 |
10 | 24V DC | 83 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
4 Circuits Controlled with 3 Off (Normally Open) and 1 On (Normally Closed)—4PST-3NO/1NC | |||||||||||
10 | 120V AC | 22 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
10 | 24V DC | 83 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | |||||||||||
10 | 120V AC | 22 | 25 A @ 240 V AC/24 V DC | __ | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
10 | 240V AC | 11 | 25 A @ 240 V AC/24 V DC | __ | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
10 | 24V DC | 83 | 25 A @ 240 V AC/24 V DC | __ | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
Infrequent-Cycle Relays




For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
Enclosures (sold separately) are NEMA 1 rated to protect contacts from corrosion.
Also Available: Auxiliary contacts for 3.8"-7.2" Ht. relays. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on (1 Normally Open) or off (1 Normally Closed).
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
2 | 24V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
2 | 120V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 | 208V AC, 240V AC | 6VA | 25A | 30A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
4 | 24V AC | 6.5VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 120V AC | 6.5VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
4 | 24V DC | 3.1W | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 6.5VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
6 | 24V AC | 7VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 120V AC | 7VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 24V DC | 3.1W | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 208V AC, 240V AC | 7VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
8 | 24V AC | 50.4VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 120V AC | 50.4VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 24V DC | 5.1W | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 208V AC, 240V AC | 50.4VA | 25A | 35A | 2 hp @ 115 V AC 3 hp @ 230 V AC | 7 1/2 hp @ 230 V AC 10 hp @ 460 V AC 10 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
Enclosures for 60A 3PST-NO Relays and 4PST-NO Relays | 00000000 | Each | 0000000 |
Safety Relays
Receive signals from safety monitoring relays or controllers to switch devices off and on because of a system failure. Also known as force-guided or mechanically linked contacts, the interlocking opposing contacts on these relays cannot be open or closed at the same time. To keep your system from receiving false switching signals, the interlocking opposing contact must remain open even if a contact welds closed.
IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. These relays have been tested to safety standards that can help you achieve your system's PL (performance level) and SIL (safety integrity level). Choose a relay with a PL and SIL rating to meet the needs of your system. Higher ratings indicate greater safety protection. As your system becomes more complex, you generally require a higher safety protection level. Mount them to 35mm DIN rail (also known as DIN 3 Rail).
Relays that meet SIL3 are tested for applications with a probability of failure of 0.01% to 0.1% and are used for preventing fires, explosions, or toxic releases. Relays that meet CAT 4 withstand circuit surges in electrical applications up to 600V.
When a failure is detected, relays with self-monitoring circuitry signal the controller to remove power and prevent restarting until the issue is resolved.
Relays with nondetachable contacts have auxiliary contacts that won’t separate from the relay if there is shock or vibration. Relays with mirror auxiliary contacts have contacts that are normally closed and cannot be open at the same time as a normally open main contact.
For technical drawings and 3-D models, click on a part number.

hp @ Switching Voltage | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Single Phase | Three Phase | Auxiliary Contact Switch Starting Position | Ht. | Wd. | Dp. | Features | Each | |
With Screw Terminals—DIN-Rail and Surface Mount | |||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||||
18 | 120V AC | 5 | 25 A @ 400 V AC | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 10 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 3.4" | 1.8" | 5.5" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 0000000 |
18 | 24V DC | 3 | 25 A @ 400 V AC | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 10 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 3.4" | 1.8" | 5.5" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays
Operate equipment that cycles on and off from your control cabinet. Often called definite-purpose contactors, these relays meet UL 508 for use with air conditioning and heating. Mount them directly to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They have recessed terminals that prevent fingers and other objects from touching live circuits. You can wire the control circuit on either side of the relay, which helps you use less wire.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay.
Use replacement coils to swap out a broken coil or change the input voltage of a relay. The full load current of the relay must match the full load current range of the coil.
For technical drawings and 3-D models, click on a part number.

Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
Relays | ||||||||||||
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 9VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 000000 |
12 | 120V AC | 9VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 9VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
Relays with 1 Off (Normally Open) Auxiliary Contact | ||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
12 | 24V AC | 9VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 9VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 9VA | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V DC | 5.4W | 25A | 30A | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 0000000 | 000000 |


Number of Circuits Controlled | For Relay Width | Switch Starting Position | Industry Designation | Mounting Location | Each | |
2 | 1.8", 2.2", 2.4" | 2 Off (Normally Open) | DPST-NO | Front | 0000000 | 000000 |
2 | 1.8", 2.2", 2.4" | 2 On (Normally Closed) | DPST-NC | Front | 0000000 | 00000 |
2 | 1.8", 2.4" | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-1NO/1NC | Front | 00000000 | 00000 |
2 | 1.8", 2.4" | 1 Off (Normally Open) and 1 On (Normally Closed) | DPST-1NO/1NC | Side | 00000000 | 00000 |
4 | 1.8", 2.2", 2.4" | 1 Off (Normally Open) and 3 On (Normally Closed) | 4PST-1NO/3NC | Front | 0000000 | 00000 |
4 | 1.8", 2.2", 2.4" | 2 Off (Normally Open) and 2 On (Normally Closed) | 4PST-2NO/2NC | Front | 0000000 | 00000 |
4 | 1.8", 2.2", 2.4" | 3 Off (Normally Open) and 1 On (Normally Closed) | 4PST-3NO/1NC | Front | 0000000 | 00000 |
4 | 1.8", 2.2", 2.4" | 4 Off (Normally Open) | 4PST-NO | Front | 0000000 | 00000 |
4 | 1.8", 2.2", 2.4" | 4 On (Normally Closed) | 4PST-NC | Front | 0000000 | 00000 |