    34 Products

    Latching Relays

    Image of Product. Front orientation. Contains Annotated. Latching Relays. Latching Relays, 10 Terminals.
    Image of Product. 10-Terminal Relay Socket. Front orientation. Relay Sockets. Latching Relays, 10 Terminals.

    10 Terminals

    10-Terminal

    Relay Socket

    A single, maintained input voltage switches these relays and latches them in position, so they don't require a constant input voltage to stay switched. A second maintained voltage will release the latch.
    Relay Sockets—Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Relays
    Relay Sockets
    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Each
    Each
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1024V AC273 amp @ 240V AC/24V DC1.1"0.8"1.4"0.102"1358T3200000001358T93000000
    1012V DC1103 amp @ 240V AC/24V DC1.1"0.8"1.4"0.102"1358T31000001358T9300000
    1024V DC523 amp @ 240V AC/24V DC1.1"0.8"1.4"0.102"1358T33000001358T9300000
     

    Solid State Spade-Terminal Relays

    Often used for high-speed switching at low-current levels, these solid state relays have no moving parts, so they switch faster, last longer, and are quieter than mechanical switches.
    Relay-Socket Mount
    Image of Product. Relay-Socket Mount. Front orientation. Contains Annotated. Relays. Solid State Spade-Terminal Relays, 1 Circuit Controlled, 0.187" Quick-Disconnect Tab Width.
    Image of Product. Sockets
with Screw
Terminals. Front orientation. Relay Sockets. Solid State Spade-Terminal Relays.

    Relay-Socket

    Mount

    Sockets with

    Screw Terminals

    Sockets with Screw Terminals—Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. Relay sockets with screw terminals can also mount to a flat surface.
    Relays
    Sockets with
    Screw Terminals
    No. of
    Terminals
    Input Voltage, V DC
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V DC
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Each
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
    85, 6, 12, 243 amp @ 48V DC481.102"0.85"1.437"0.187"9250K40000007122K22000000
     

    DIN-Rail Mount Solid State Interface Relays

    With no moving parts, these solid state relays last longer, switch faster, and are quieter than mechanical relays. They interface between your controller and components to isolate input and output circuits, which protects components from voltage spikes, amplifies the relay’s signal, and reduces interference for reliable transmission. The relay’s LED indicator shines when it’s powered on, so you know at a glance which relays are wired correctly and what the switching position is. These relays are often used for switching small motors and sensors. Rated IP20, they prevent fingers and other objects from touching live circuits.
    Mount them on 35 mm DIN rail (also known as DIN 3 rail) with the included socket. Relays disconnect from the socket for easy replacement.
    1 Circuit Controlled with 1 Off—SPST-NO
    Image of Product. Front orientation. Contains Annotated. Interface Relays. DIN-Rail Mount Solid State Interface Relays, 1 Circuit Controlled, With Screw Terminals.

    With Screw

    Terminals

    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V DC
    Ht.
    Wd.
    Dp.
    Features
    Each
    With Screw Terminals
    524V DC8.53 amp @ 30V DC333.1"0.2"3.6"LED Power Indicator8299K14000000
     

    Interface Safety Relays

    Image of Specification. Front orientation. Contains Annotated. Safety Relays. Interface Safety Relays.
    These relays pair the transmission reliability of an interface relay with the fail-safe operation of a safety relay. Use them to communicate signals to devices like motors or sensors. They have interlocking contacts—also known as force-guided or mechanically linked contacts—so opposing contacts won't close at the same time. This minimizes the chance of arcing, so electricity won't jump across the contacts and interfere with your relay or system. They also have an interface that isolates input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. Mount them on 35 mm DIN rail (also known as DIN 3 rail). The relays disconnect from the socket for quick replacement.
    LED Indicator—Relays with LED indicator light up when the relay is on, so you’ll know it’s wired correctly and can tell at a glance whether it’s on or off.
    Safety Relays
    Replacement
    Safety Relays
    No. of
    Terminals
    Input Voltage,
    V DC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Mechanical
    Life Cycles
    Ht.
    Wd.
    Dp.
    Features
    Each
    Each
    2 Circuits Controlled with 1 Off and 1 On—DPST-1NO/1NC
    612633 amp @ 240V AC/24V DC250V AC, 125V DC10,000,0001.1"0.5"1.1"Interlocked Opposing Contacts, LED Indicator8722N120000008722N13000000
     

    Hazardous Location Relays

    Image of Product. Back orientation. Relays. Hazardous Location Relays, Quick-Disconnect Terminals—Hermetically Sealed.
    Image of Product. Front orientation. Relay Sockets. Hazardous Location Relays.

    Quick-Disconnect

    Terminals—Hermetically

    Sealed

    Sockets with

    Screw Terminals

    Sealed for safety, these relays are a good choice for hazardous locations where combustible or corrosive gases may be present.
    Quick-Disconnect Terminal—Relays with circular-pin terminals or quick-disconnect terminals are hermetically sealed—completely air- and watertight—to shield internal parts from gases, moisture, and other contaminants. They plug into relay sockets (sold separately) for easy installation.
    Sockets with Screw Terminals—Relay sockets mount to 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces.
    Relays
    Sockets with
    Screw Terminals
    No. of
    Terminals
    Input Voltage,
    V AC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching
    Voltage
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Hazardous Location Rating
    Each
    Each
    Quick-Disconnect Terminals—Hermetically Sealed
     
    4 Circuits Controlled with 4 Off or 4 On—4PDT
    141201003 amp @ 120V AC/240V AC2401/10 hp @ 120V AC1.2"0.9"1.3"0.125"NEC Class I Division 2 Groups A, B, C, D
    8161N1100000007122K25000000
     

    Circuit Board Safety Relays

    Image of Product. Front orientation. Contains Annotated. Safety Relays. Circuit Board Safety Relays, 8 Terminals.

    8 Terminals

    Reduce connection errors on circuit boards that control machine guards and other safety devices. Also known as force-guided contact relays, they have contact pairs that won’t close at the same time, even if contacts stick or weld shut. These relays take up less space on a board than those with electrical wiring because their solder pin terminals mount directly through circuit board holes. Use them to control high-power components, such as fans and heaters, from a low-power circuit.
    Mechanical Indicator—Relays with a mechanical indicator show you whether they’re switched on or off with a flag. Peek through the window on the side to quickly check the flag’s position.
    No. of
    Terminals
    Input Voltage,
    V DC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Mechanical
    Life Cycles
    Ht.
    Wd.
    Dp.
    Pin
    Lg.
    Features
    Each
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    824293 amp @ 240V AC/24V DC250V AC, 125V DC10,000,0001.1"0.5"1"0.16"Interlocked Opposing Contacts, Mechanical Indicator6253N12000000
     

    Solid State DIN-Rail Mount Multifunction Timer Relays

    Image of Product. Relays with 4 Circuits Controlled. Front orientation. Contains Annotated. Timer Relays. Solid State DIN-Rail Mount Multifunction Timer Relays, Timing-Adjustment Knob, 4 Circuits Controlled.

    Relays with 4

    Circuits Controlled

    For fast installation, mount these relays to 35 mm DIN rail (also known as DIN 3 rail). They also mount to flat surfaces. With no moving parts, these solid state relays last longer and require less maintenance, are quieter, and switch faster than mechanical relays. They provide a variety of timing functions in one relay.
    4 Circuits Controlled—Relays that control 4 circuits require a relay socket (sold separately) to attach to DIN rail.
    Timer Relays
    Sockets
    Timing
    Range
    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Timer Relay Function
    No.
    of
    Overall
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Each
    Each
    Timing-Adjustment Knob
     
    4 Circuits Controlled with 4 Off or 4 On—4PDT
    14120V AC15Delayed Start (Delay on Make)
    Interval
    Repeat Cycle
    40.1 sec. to 10 min.3 amp @ 240V AC2501.1"0.9"2.1"7339K400000007122K25000000
    14240V AC9Delayed Start (Delay on Make)
    Interval
    Repeat Cycle
    40.1 sec. to 10 min.3 amp @ 240V AC2501.1"0.9"2.1"7339K60000007122K2500000
    1424V DC45Delayed Start (Delay on Make)
    Interval
    Repeat Cycle
    40.1 sec. to 10 min.3 amp @ 240V AC2501.1"0.9"2.1"7339K20000007122K2500000
     

    Network-Enabled Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Network-Enabled Relays, 2 Circuits Controlled.

    2 Circuits

    Controlled

    With a built-in web server, these relays can be remotely controlled over any IP network, including the Internet. They connect to your network either wirelessly or with an Ethernet cable (not included). No programming or software is required to operate these relays. Instead, use your web browser to input the relay’s IP address and the website guides you through simple menus and drop-down lists to set your parameters. Alternatively, you can use these relays with a PLC or without a computer at all if you use one relay as a controller for another relay.
    Each circuit has a digital input that can be used to control the relay or a remote relay over the IP network. You could also use the digital input to monitor a separate device, such as a push-button or door alarm switch. These relays can be set to automatically restart network devices, such as computers, even when they fail to respond to relay signals. LED indicators let you know if there’s input and output voltage and if the network is connected and active. All meet at least one safety standard.
    Mount these relays on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces.
    2 Circuits Controlled—Relays that control 2 circuits can also be programmed from a downloadable app or programs written in BASIC script, making them easy to customize. The website logs and stores data and device information.
    Power Over Ethernet Standard—Power over Ethernet (PoE) compatible relays can receive power from PoE cables (not included).
    Digital
    Inputs
    Digital
    Outputs
    No. of
    Terminals
    Voltage
    No.
    of
    Voltage
    No.
    of
    Control Current,
    amp
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V DC
    Ht.
    Wd.
    Dp.
    Signal
    Type
    PoE Std.
    Control Communication
    Protocol
    Operating System Compatibility
    Features
    Each
    2 Circuits Controlled with 1 Off or 1 On—SPDT
    144V DC
    6V DC
    12V DC
    24V DC
    23V DC
    5V DC
    11V DC
    23V DC
    233 amp @ 24V DC243.9"1.4"3.1"DataModbus TCP/IP, SMTPAndroid 6.0 or Later, iOS 9.0 or Later, Windows XP or LaterLED Indicators, Data Logging Capabilities7059N130000000
    144V DC
    6V DC
    12V DC
    24V DC
    211V DC233 amp @ 24V DC243.9"1.4"3.1"DataPoE Type 1Modbus TCP/IP, SMTPAndroid 6.0 or Later, iOS 9.0 or Later, Windows XP or LaterLED Indicators, Data Logging Capabilities7059N14000000
     

    Multifunction Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Multifunction Monitoring Relays.
    Monitor phase, voltage, and frequency at the same time to protect motors, generators, and other three-phase circuits from burning out or overheating. They'll switch the circuit off if they detect voltage or frequencies outside of the set range or phase loss, imbalance, or reversal. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays use IO-Link, so they can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Voltage,
    V AC
    Input Freq.,
    Hz
    Trip Freq.,
    Hz
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Screw Terminals with IO-Link
    122490 to 76050, 6015 to 700.1 to 30Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.9"0.9"3.6"8449N120000000
     
    Spring-Clamp Terminals with IO-Link
    122490 to 76050, 6015 to 700.1 to 30Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.9"0.9"3.6"8449N11000000
     

    Safety Relays with Diagnostic Capabilities

    Image of Product. Relay. Front orientation. Contains Annotated. Safety Relays. Safety Relays with Diagnostic Capabilities, DIN-Rail Mount.
    Image of Product. Relay with Time Delay. Front orientation. Contains Annotated. Safety Relays. Safety Relays with Diagnostic Capabilities, 2 Safety Outputs, DIN-Rail Mount.

    Relay

    Relay with

    Time Delay

    Control and diagnose issues with safety-critical circuits. These relays have a microprocessor that monitors safety components, such as emergency stops and light curtains, and sends a signal to stop the operation if a failure is detected and restart when the issue is resolved. They also help with diagnostic tasks because of their feedback circuit, which allows basic relays to communicate their status back to the safety relay. These relays have a duplicate set of input and output signals, so they’ll still stop the controlled device if one of the inputs fails.
    IP20 rated, they have recessed terminals which prevent fingers and other objects from touching live circuits. These relays have been tested to multiple safety standards and can help achieve PL, SIL, or CAT system ratings. They also meet ISO and IEC standards for machine safety.
    Mount them to 35 mm DIN rail (also known as DIN 3 Rail) for fast installation.
    Time Delay—Relays with delayed safety outputs are often used where power must be maintained after an input signal is received. For example, after a stop button for a machine is pressed, the guard door will stay locked until the machine cycle is finished.
    No. of
    Terminals
    Input
    Voltage
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Ht.
    Wd.
    Dp.
    For Use With
    Mounting
    Location
    Max. System
    Safety Rating
    Features
    Each
    2 Circuits Controlled
     
    2 Safety Outputs with 2 Off and 2 Delayed Safety Outputs with 2 Off
    1624V DC3 amp @ 240V AC
    3 amp @ 24V DC
    250V AC, 250V DC3.9"0.9"4.5"Emergency Stops, Safety Light CurtainsDIN RailPLe, SIL 3Time Delay6322N150000000
     
    3 Safety Outputs with 2 Off and 1 Signal Output with 2 On
    16240V AC3 amp @ 240V AC
    2.5 amp @ 24V DC
    250V AC, 250V DC3.9"1.8"4.5"Emergency StopsDIN RailPLe, SIL 36322N13000000
     
    Auxiliary Contact Blocks for Relays with DC Input Voltage

    Current-Monitoring Relays

    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Screw Terminals with IO-Link, Keypad Adjustment.
    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Spring-Clamp Terminals with IO-Link, Keypad Adjustment.

    Screw Terminals

    with IO-Link,

    Keypad Adjustment

    Spring-Clamp

    Terminals with

    IO-Link, Keypad

    Adjustment

    Protect electrical equipment from overcurrent and undercurrent damage—these relays continuously monitor current flow. When current is outside a set range, they trip and cut power to prevent overheating, fire hazards, and stalling. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    IO-Link Communication Protocol—Relays with IO-Link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Current,
    amp
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Digital Display
    Type
    Each
    Screw Terminals with IO-Link
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    9240.05 to 100 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.6"0.9"3.4"LCD8123N110000000
     
    Spring-Clamp Terminals with IO-Link
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    9240.05 to 100 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.8"0.9"3.4"LCD8123N12000000
     

    Ground-Fault Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals with IO-Link.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Spring-Clamp Terminals with IO-Link.

    Screw Terminals with

    IO-Link

    Spring-Clamp

    Terminals with

    IO-Link

    Detect and mitigate ground faults to prevent harm to equipment, circuits, and people. These relays monitor the differential between incoming and outgoing current, also known as residual current. When the balance is off, they trip and cut power to the circuit. These relays are highly sensitive, so you can trust them to de-energize faulty circuits before a minor issue becomes a major one. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays require a current-indicating ring (sold separately) to operate. Choose a ring that is large enough for your lines to pass through. Feed the lines of the circuit through the center of the ring and connect the indicating ring output to the relay.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because they don’t have screws, there’s less of a risk that they will loosen over time, even when they’re under vibration.
    IO-Link Communication Protocol—Relays with IO-Link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Current,
    amp
    Trip Time,
    sec.
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw Terminals with IO-Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    12240.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4"0.9"3.6"Remote Reset8121N1090000000
     
    Spring-Clamp Terminals with IO-Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    12240.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4.1"0.9"3.6"Remote Reset8121N111000000
     
    Current Indicating Rings

    Energy-Saving Motor Starters

    Image of Product. Front orientation. Motor Starters. Energy-Saving Motor Starters.
    Save electricity and extend motor life by reducing the motor's starting current. These starters gradually start and stop motors. Use them on motors where torque varies, such as pumps, compressors, and conveyors. All have an auxiliary contact to send a signal or connect to another device, such as an alarm or indicating light.
    Switching
    Time, sec.
    Full Load
    Current, amp
    Input Voltage,
    V DC
    Voltage,
    V AC
    Current,
    amp
    Electrical Phase
    Accel.
    Deceleration
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Certification
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    324208 to 6003Three (3/4 hp @ 240V AC)
    Three (2 hp @ 480V AC)
    1 to 200 to 204.7"1.8"DIN Rail, Surface35UL Listed, C-UL Listed, CE Marked
    7112T50000000
     

    Voltage-Monitoring Relays

    Safeguard your equipment against overheating, wear, and malfunction from a spike or dip in voltage. These relays continuously monitor your AC or DC power supply and trip when the voltage is outside a set range. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Monitoring Relays with IO-Link
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Voltage-Monitoring Relays, Monitoring Relays with IO-Link.
    Relays with IO-Link can be programmed, monitored and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    With Spring-Clamp Terminals—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Voltage
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Digital Display
    Type
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    With Screw Terminals
    92410V AC to 600V AC, 10V DC to 600V DC0 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.6"0.9"3.6"LCDRemote Reset8446N1050000000
     
    With Spring-Clamp Terminals
    92410V AC to 600V AC, 10V DC to 600V DC0 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.8"0.9"3.6"LCDRemote Reset8446N106000000
     
    back to top