About Timer Relays
More
DIN-Rail Mount Interface Relays



Isolate input and output circuits to prevent damage from voltage spikes, reduce signal interference, and amplify signal. These relays interface between your controller and components—they receive a signal from the controller to switch power on or off to the components. All have an LED indicator that shows you if your switch is actuated, so you know it’s connected and wired correctly. Use them to communicate signals to devices like motors or sensors. Mount them on 35 mm DIN rail (also known as DIN 3 rail).
Relays with spring-clamp terminals connect and disconnect to wires without needing to turn screws. Because there is no screw, these connections have less risk of loosening over time than screw terminals, even when there is vibration.
Relays with a fuse holder slot give you the option for additional overload protection. If the current exceeds the fuse’s rating, the fuse will blow and break the circuit. This prevents the relay from overheating, breaking, or causing a fire. The fuse holder is sold separately. You can use these relays without the fuse holder as a standard interface relay.
For technical drawings and 3-D models, click on a part number.
Relays with Relay Sockets | Replacement Relays | Fuse Holders | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ 240V AC | Ht. | Wd. | Dp. | Features | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
With Screw Terminals | |||||||||||||
5 | 24V AC, 24V DC | 11 | 6A | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 000000 | 0000000 | 00000 | 00000000 | 00000 |
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6A | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 120V AC, 120V DC | 5 | 6A | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
With Spring-Clamp Terminals | |||||||||||||
5 | 24V AC, 24V DC | 11 | 6A | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 240V DC | 19 | 6A | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
5 | 120V AC, 120V DC | 5 | 6A | 3.7" | 0.2" | 3.5" | Fuse Holder Slot, LED Indicator | 00000000 | 00000 | 0000000 | 0000 | 00000000 | 0000 |
Safety Relays
Receive signals from safety monitoring relays or controllers to switch devices off and on because of a system failure. Also known as force-guided or mechanically linked contacts, the interlocking opposing contacts on these relays cannot be open or closed at the same time. To keep your system from receiving false switching signals, the interlocking opposing contact must remain open even if a contact welds closed.
IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. These relays have been tested to safety standards that can help you achieve your system's PL (performance level) and SIL (safety integrity level). Choose a relay with a PL and SIL rating to meet the needs of your system. Higher ratings indicate greater safety protection. As your system becomes more complex, you generally require a higher safety protection level. Mount them to 35mm DIN rail (also known as DIN 3 Rail).
Relays that meet SIL2 are tested for applications with a probability of failure of 0.1% to 1%. They’re often used for emergency shutdowns, and fire, gas, and overpressure detection.
For technical drawings and 3-D models, click on a part number.

Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
With Screw Terminals—DIN-Rail Mount | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
2 Circuits Controlled with 1 Off (Normally Open) and 1 On (Normally Closed)—DPST-1NO/1NC | ||||||||||
8 | 120V AC | 9 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
8 | 24V DC | 38 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 00000 |
3 Circuits Controlled with 2 Off (Normally Open) and 1 On (Normally Closed)—3PST-2NO/1NC | ||||||||||
8 | 24V DC | 26 | 10 A @ 240 V AC | 250V AC | 3.5" | 0.7" | 2.4" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 00000 |
4 Circuits Controlled with 2 Off (Normally Open) and 2 On (Normally Closed)—4PST-2NO/2NC | ||||||||||
12 | 120V AC | 10 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
12 | 24V DC | 42 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
4 Circuits Controlled with 3 Off (Normally Open) and 1 On (Normally Closed)—4PST-3NO/1NC | ||||||||||
12 | 120V AC | 10 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
12 | 24V DC | 42 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
6 Circuits Controlled with 4 Off (Normally Open) and 2 On (Normally Closed)—6PDT-4NO/2NC | ||||||||||
16 | 120V AC | 10 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
16 | 24V DC | 42 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
6 Circuits Controlled with 5 Off (Normally Open) and 1 On (Normally Closed)—6PDT-5NO/1NC | ||||||||||
16 | 24V DC | 42 | 6 A @ 240 V AC | 250V AC | 3.4" | 0.9" | 3.9" | Interlocked Opposing Contacts, Recessed Terminals, LED Indicator | 00000000 | 000000 |
High-Starting-Current DIN-Rail Mount Timer Relays

Reduce voltage fluctuations and stress on shafts and bearings when starting up three-phase motors. These timer relays start with motor contacts in a star configuration, then switch to a delta configuration after a set delay. Since star configuration takes less voltage to start than delta, these relays prevent voltage dips that often happen when a motor starts and are gentler on mechanical parts. Mount these relays directly to 35 mm DIN rail (also known as DIN 3 rail) for quick installation.
For technical drawings and 3-D models, click on a part number.
Timing Range | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Each | |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
5 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 30V DC, 48V DC, 60V DC, 120V DC, 240V DC | 5 | Star-to-Delta | 6 | 0.1 sec.-20 min. | 6A | 250V AC | 3.4" | 0.7" | 2.4" | 0000000 | 000000 |