McMaster-Carr logo
    Filter by
    System of Measurement
    Mounting Location
    Switch Designation
    Industrial Info Compare
    Switching Voltage
    Industrial Info Snippet
    Switch Action
    Industrial Info Compare
    Number of Circuits Controlled
    Adjustment Mechanism
    Switching Current
    Industrial Info Snippet
    Wire Connection
    Number of Terminals
    Switch Starting Position
    Industrial Info Compare
    Mechanical Life Cycles
    Height
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Relay Type
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    11 Products

    Ground-Fault Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals, Knob Adjustment.

    Screw Terminals

    Screw Terminals

    Knob Adjustment

    Detect and mitigate ground faults to prevent harm to equipment, circuits, and people. These relays monitor the differential between incoming and outgoing current, also known as residual current. When the balance is off, they trip and cut power to the circuit. These relays are highly sensitive, so you can trust them to de-energize faulty circuits before a minor issue becomes a major one. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays require a current-indicating ring (sold separately) to operate. Choose a ring that is large enough for your lines to pass through. Feed the lines of the circuit through the center of the ring and connect the indicating ring output to the relay.
    Knob Adjustment—Relays with knob adjustments have knobs right on the front where you can set your trip current.
    LED Indicator—Relays with an LED indicator show the status of your relay, so you know it is wired correctly and when it is actuated.
    No. of
    Terminals
    Input Voltage, V AC
    Trip Current
    Setting, amp
    Trip Current,
    amp
    Trip Time,
    sec.
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment
    Mechanism
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw Terminals
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224, 48, 120, 2400.0305 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    3.2"1.4"2.6"LED Indicator8121N1010000000
    1224, 48, 120, 2400.305 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    3.2"1.4"2.6"LED Indicator8121N102000000
    1224, 48, 120, 2400.03 to 50 to 55 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    Knob3.2"1.4"2.8"LED Indicator8121N103000000
    1224, 48, 120, 2400.3 to 300 to 55 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    Knob3.2"1.4"2.8"LED Indicator8121N104000000
     
    Current Indicating Rings

    Frequency-Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Frequency-Monitoring Relays, DIN-Rail Mount.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Frequency-Monitoring Relays, Relay-Socket Mount.

    DIN-Rail Mount

    Relay-Socket Mount

    Prevent changes in frequency from damaging sensitive equipment. Often used with motors, fluorescent lighting, and controllers, these relays cut power to your device if the frequency falls outside the set range. Switches on the front of these relays let you set your trip frequency and time. You can see that they're wired correctly and when they're actuated based on the LED indicators. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits.
    DIN-Rail Mount—DIN-rail mount relays snap onto 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Relay-Socket Mount—Relay-socket mount relays plug into a socket (sold separately), which is required for installation.
    Monitoring Relays
    Sockets
    Trip Frequency
    Setting, Hz
    No. of
    Terminals
    Input Voltage, V AC
    50 Hz Input
    60 Hz Input
    Trip Time,
    sec.
    Reset Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment
    Mechanism
    Ht.
    Wd.
    Dp.
    Features
    Each
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    DIN-Rail Mount
    924, 48, 120, 24040 to 60
    48 to 52
    50 to 70
    58 to 62
    0.1 to 30Automatic, Manual8 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    DIP Switch3.1"0.9"3.9"LED Indicator8477N110000000———0
     
    Relay-Socket Mount
    124, 48, 120, 24040 to 60
    48 to 52
    50 to 70
    58 to 62
    0.1 to 30Automatic, Manual8 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    DIP Switch3.1"1.4"3.7"LED Indicator8477N120000007122K12000000
     