Tank-Mount Hydraulic Fluid Filters
Mount to the top of a tank to clean hydraulic fluid in return lines. A pressure relief valve protects against excess pressure that can build up when a cartridge is clogged. When the difference in pressure before and after the filter exceeds the opening pressure, the relief valve opens. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
Filters with 24 gpm and 87 gpm maximum flow rate drain into the tank through a tube or pipe (not included), preventing fluid splashes that create harmful air bubbles. Filters with 43 gpm maximum flow rate drain directly into the tank.
For technical drawings and 3-D models, click on a part number.
Inlet Connection— UN/UNF (SAE Straight) | Outlet Connection | O'all | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Relief Valve Opening Pressure, psid | Thread Size | Dash Size | Connection Type | Dash Size | No. of Indicator/Gauge Ports | Filter Efficiency | Ht. | Wd. | Removes Particle Size Down To, microns | Each | |
Fiberglass Media—Aluminum Housing | |||||||||||||
23 | 100 | 47 | 1 1/16"-12 | 12 | 1" Male Barbed | 16 | 1 | 99.9% | 9 11/16" | 4 3/8" | 000000 | 0000000 | |
43 | 100 | 47 | 1 5/16"-12 | 16 | 1 1/4" ID × 1 1/2" OD | __ | 1 | 99.9% | 11 3/8" | 5 7/16" | 000000 | 000000 | |
87 | 100 | 47 | 1 7/8"-12 | 24 | 2 NPT Female | 32 | 1 | 99.9% | 10 7/16" | 7 5/16" | 000000 | 000000 |
Return Grilles
Cover the opening where air is pulled into your HVAC system.
For technical drawings and 3-D models, click on a part number.
For Duct | Face Plate | |||||||
---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Color | Ht. | Wd. | Mounting Location | Mounting Fasteners Included | Each | |
Painted Aluminum | ||||||||
6" | 6" | White | 7 3/4" | 7 3/4" | Wall | Yes | 0000000 | 000000 |
8" | 8" | White | 9 3/4" | 9 3/4" | Wall | Yes | 0000000 | 00000 |
10" | 10" | White | 11 3/4" | 11 3/4" | Wall | Yes | 0000000 | 00000 |
12" | 12" | White | 13 3/4" | 13 3/4" | Wall | Yes | 0000000 | 00000 |
Painted Steel | ||||||||
6" | 12" | White | 7 3/4" | 13 3/4" | Wall | Yes | 000000 | 0000 |
6" | 14" | White | 7 3/4" | 15 3/4" | Wall | Yes | 000000 | 0000 |
8" | 12" | White | 9 3/4" | 13 3/4" | Wall | Yes | 000000 | 0000 |
8" | 14" | White | 9 3/4" | 15 3/4" | Wall | Yes | 000000 | 0000 |
10" | 12" | White | 11 3/4" | 13 3/4" | Wall | Yes | 000000 | 00000 |
10" | 14" | White | 11 3/4" | 15 3/4" | Wall | Yes | 000000 | 00000 |
12" | 12" | White | 13 3/4" | 13 3/4" | Wall | Yes | 000000 | 00000 |
12" | 14" | White | 13 3/4" | 15 3/4" | Wall | Yes | 000000 | 00000 |
14" | 14" | White | 15 3/4" | 15 3/4" | Wall | Yes | 0000000 | 00000 |
14" | 24" | White | 15 3/4" | 25 3/4" | Wall | Yes | 0000000 | 00000 |
16" | 16" | White | 17 3/4" | 17 3/4" | Wall | Yes | 0000000 | 00000 |
16" | 20" | White | 17 3/4" | 21 3/4" | Wall | Yes | 0000000 | 00000 |
20" | 16" | White | 21 3/4" | 17 3/4" | Wall | Yes | 0000000 | 00000 |
20" | 20" | White | 21 3/4" | 21 3/4" | Wall | Yes | 0000000 | 00000 |
24" | 14" | White | 25 3/4" | 15 3/4" | Wall | Yes | 0000000 | 00000 |
24" | 24" | White | 25 3/4" | 25 3/4" | Wall | Yes | 0000000 | 00000 |
30" | 14" | White | 31 3/4" | 15 3/4" | Wall | Yes | 0000000 | 00000 |
Drop-Ceiling Return Grilles with Filter Holder
Place these grilles in the grid of a drop ceiling to create return airflow to your HVAC system without a duct. Add a filter (not included) for protection against dust and debris.
Return Grilles with Filter Holder
Add a filter (not included) to these grilles for protection against dust and debris entering your HVAC system. Select a filter that matches your duct size.
For technical drawings and 3-D models, click on a part number.
For Duct | Face Plate | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Color | Ht. | Wd. | For Filter Thick. | Mounting Location | Mounting Fasteners Included | Mounting Hole Dia. | Each | |
Painted Steel | ||||||||||
14" | 14" | White | 16 13/16" | 16 13/16" | 1" | Wall | No | 1/4" | 00000000 | 000000 |
14" | 20" | White | 16 13/16" | 22 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
14" | 30" | White | 16 13/16" | 32 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
16" | 16" | White | 18 13/16" | 18 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
16" | 20" | White | 18 13/16" | 22 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
16" | 25" | White | 18 13/16" | 27 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
20" | 14" | White | 22 13/16" | 16 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
20" | 16" | White | 22 13/16" | 18 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
20" | 25" | White | 22 13/16" | 27 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
24" | 12" | White | 26 13/16" | 14 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
24" | 14" | White | 26 13/16" | 16 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
25" | 16" | White | 27 13/16" | 18 13/16" | 1" | Wall | No | 1/4" | 00000000 | 00000 |
Oil-Mist-Eliminating Exhaust Filters
Stop oil mist and smoke from exiting your equipment and into your environment. These exhaust filters are commonly used with small oil-sealed vacuum pumps. Install them on the outlet.
Filters with nickel-plated steel housing have better corrosion resistance than filters with a steel housing.
For technical drawings and 3-D models, click on a part number.
O'all | Element | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Max. Flow Rate | Max. Pressure | Max. Temp., °F | Ht. | Dia. | Removes Particle Size Down To, microns | Filter Efficiency | Ht. | ID | OD | Material | Housing Material | Each | |
1/2 | NPT | Male | 4.5 scfm @ 2 psi | Not Rated | 220° | 4 1/2" | 2 1/2" | 0.3 | 99.9% | 3" | 1 1/4" | 2 1/4" | Fiberglass | Nickel-Plated Steel | 0000000 | 0000000 |
3/4 | NPT | Male | 4.5 scfm @ 2 psi | Not Rated | 220° | 4 5/8" | 2 1/2" | 0.3 | 99.9% | 3" | 1 1/4" | 2 1/4" | Fiberglass | Nickel-Plated Steel | 0000000 | 000000 |
1 | NPT | Female | 40 scfm @ 14.7 psi | 3 psi | 220° | 6 3/4" | 7 3/8" | 0.3 | Not Rated | 4 3/4" | 2 9/16" | 5" | Fiberglass | Steel | 00000000 | 000000 |
1 1/2 | NPT | Female | 50 scfm @ 14.7 psi | 3 psi | 220° | 6 3/4" | 7 3/8" | 0.3 | Not Rated | 4 3/4" | 2 9/16" | 5" | Fiberglass | Steel | 00000000 | 000000 |
2 | NPT | Female | 125 scfm @ 14.7 psi | 14.7 psi | 220° | 11 1/4" | 8 3/4" | 0.3 | Not Rated | 8 7/16" | 3 1/2" | 5 7/8" | Fiberglass | Steel | 00000000 | 000000 |
Odor-Absorbing High-Vacuum Oil-Mist-Eliminating Exhaust Filters
To keep airborne oil and odor out of your work environment, connect these filters to your high-vacuum oil pump. They purify pump exhaust in two stages: a fiberglass layer captures oil and collects it into a drain, and an active carbon layer removes any odor-causing oil or chemical vapors. Attach the quick-clamp fitting on the filter inlet to your high-vacuum pump. Use a ring and clamp (sold separately) to complete the connection.
O'all | Element | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
High-Vacuum Flange Size | Flange OD | For Tube OD | Max. Flow Rate | High Vacuum Connection Type | Max. Vacuum | Max. Temp., °F | Ht. | Dia. | Removes Particle Size Down To, microns | Filter Efficiency | Ht. | OD | Material | Each | |
Epoxy-Coated Steel Housing | |||||||||||||||
16 | 1.18" | 3/4" | 11 scfm @ 14.7 psi | ISO-KF | Not Rated | 110° | 8 3/8" | 4 1/8" | 0.3 | 99.9% | 3 3/4" | 3" | Fiberglass and Carbon | 0000000 | 0000000 |
25 | 1.57" | 1" | 11 scfm @ 14.7 psi | ISO-KF | Not Rated | 110° | 8 3/8" | 4 1/8" | 0.3 | 99.9% | 3 3/4" | 3" | Fiberglass and Carbon | 0000000 | 000000 |
Ht. | OD | Removes Particle Size Down To, microns | Filter Efficiency | Reinforcement Type | Each | |
Fiberglass and Carbon | ||||||
---|---|---|---|---|---|---|
3 3/4" | 3" | 0.3 | 99.9% | Epoxy-Coated Steel Wire | 0000000 | 0000000 |
High-Vacuum Oil-Mist-Eliminating Exhaust Filters
Clamp these exhaust filters onto oil-sealed, high-vacuum pumps to remove oil, smoke, and other contaminants and keep workplace air clean. Once captured, the oil returns to the pump to be reused. Instead of a threaded connection, these filters have a quick-clamp high-vacuum fitting, which is commonly found on high-vacuum pumps. Quick-clamp high-vacuum fittings are also known as KF, QF, and NW fittings; they require a ring and clamp (sold separately) to complete the connection.
For technical drawings and 3-D models, click on a part number.
O'all | Element | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
High-Vacuum Flange Size | Flange OD | For Tube OD | Max. Flow Rate | High Vacuum Connection Type | Max. Vacuum | Max. Temp., °F | Ht. | Dia. | Removes Particle Size Down To, microns | Filter Efficiency | Ht. | ID | OD | Material | Each | |
Nickel-Plated Steel Housing | ||||||||||||||||
16 | 1.18" | 3/4" | 4.5 scfm @ 14.7 psi | ISO-KF | Not Rated | 180° | 4" | 2 1/2" | 0.3 | 99.9% | 3" | 1 1/4" | 2 1/4" | Fiberglass | 0000000 | 0000000 |
25 | 1.57" | 1" | 4.5 scfm @ 14.7 psi | ISO-KF | Not Rated | 180° | 4" | 2 1/2" | 0.3 | 99.9% | 3" | 1 1/4" | 2 1/4" | Fiberglass | 0000000 | 000000 |
25 | 1.57" | 1" | 24 scfm @ 14.7 psi | ISO-KF | Not Rated | 180° | 8 5/16" | 5" | 0.3 | 99.9% | 6" | 3" | 4" | Fiberglass | 0000000 | 000000 |
40 | 2.16" | 1 1/2" | 55 scfm @ 14.7 psi | ISO-KF | Not Rated | 180° | 8 3/16" | 10 1/4" | 0.3 | 99.9% | 6" | 8" | 9" | Fiberglass | 0000000 | 000000 |