    RTD Probes for Liquids and Gas

    Image of Product. Front orientation. RTDs. RTD Probes for Liquids and Gas.
    Obtain more precise and reliable liquid and gas temperature measurements than thermocouple probes. Some of these probes meet DIN standards for accuracy, meaning they’re precise even with fast temperature changes.
    IP68 Enclosure Rating and IP69K Enclosure Rating—IP68- and IP69K-rated probes have plug-in connections that can handle brief submersion and harsh washdowns.
    Probe
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Enclosure
    Rating
    Specs. Met
    Each
    4-Pin Micro M12 Plug-In Connection—316L Stainless Steel Probe
    100-40 to 3002"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A00000000000000
    100-40 to 3002 3/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3003 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3005 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3006 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3007 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3009 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30010 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30013 3/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30014 1/8"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30022"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 3006 1/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 3006 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30010 1/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30010 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30014 1/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30014 1/8"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30022"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
     
    Cords

    Threaded RTD Probe Transmitters for Liquids and Gas

    Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in 4-20mA transmitter, these RTDs don’t require a separate signal converter. They have an NPT male probe connection, so they’re ready to screw into thermowells and other fittings on pipe and tanks. Made of 316 or 316L stainless steel, they resist corroding from harsh cleaning chemicals. This stainless steel also protects the RTD sensor inside from impact. They are also often installed in bores to measure the temperature of molds and dies. CE marked, they meet European safety standards.
    4-Pole Micro M12 Plug-In Connection
    Image of Product. Front orientation. Contains Annotated. RTDs. Threaded RTD Probe Transmitters for Liquids and Gas, Micro M12 Connection.
    Fixed Probe—Fixed RTDs can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
    IO Link Communication Protocol—RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet EN 60751 Class A standards for temperature accuracy. UL and C-UL listed, they meet American and Canadian safety standards.
    Probe
    RTD Probe Resistance,
    ohm
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Voltage,
    V DC
    Max. Pressure,
    psi
    Output Current,
    mA
    Communication
    Protocol
    Overall
    Lg.
    Fitting Material
    Temp.,
    ° F
    Each
    NPT Male Probe Connection—Fixed 316L Stainless Steel Probe (IP67, IP68, IP69K)
    1,00011/16"1/4"±0.5%31/2
    18 to 325,8004 to 20IO Link4 1/8"316L Stainless Steel
    0 to 30000000000000000
    1,0001 1/2"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link5"316L Stainless Steel
    0 to 3000000000000000
    1,0003 1/2"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link7"316L Stainless Steel
    0 to 3000000000000000
    1,0005 7/16"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link8 7/8"316L Stainless Steel
    0 to 3000000000000000
     
    Cords

    Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gas

    Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're made of stainless steel, so they won't corrode from harsh cleaners and sanitizers. The housing is IP69K rated, meaning it withstands high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. They have a flange that will connect to sanitary quick clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
    Program these probes with the touchscreen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
    5-Pole Micro M12 Plug-In Connection
    Image of Product. Front orientation. Contains Annotated. RTDs. Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gas.
    Image of Attribute. Three-Color Display. Front orientation. ZoomedIn view. Contains MultipleImages. Multicolored Backlit Display. Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gas.

    Three-Color Display

    RTDs
    Cords
    Probe
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Flange
    OD
    Max. Pressure,
    psi
    Overall
    Lg.
    Specs. Met
    Voltage,
    V DC
    Output Current,
    mA
    Features
    Each
    Each
    316L Stainless Steel Probe with 304 Stainless Steel Head (IP69K)
     
    For 1 1/2" OD Tubes
    100-55 to 4802"5/16"±0.1%251.988"5806 3/4"EN 60751 Class B8 to 354 to 20Multicolored Backlit Display, Touchscreen000000000000000000000000000
     
    back to top