    54 Products

    RTD Probes for Liquids and Gas

    Obtain more precise and reliable liquid and gas temperature measurements than thermocouple probes. Some of these probes meet DIN standards for accuracy, meaning they’re precise even with fast temperature changes.
    RTDs
    Image of Product. Front orientation. RTDs. RTD Probes for Liquids and Gas.
    IP68 Enclosure Rating and IP69K Enclosure Rating—IP68- and IP69K-rated probes have plug-in connections that can handle brief submersion and harsh washdowns.
    Probe
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Enclosure
    Rating
    Specs. Met
    Each
    4-Pin Micro M12 Plug-In Connection—316L Stainless Steel Probe
    100-40 to 3002"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A00000000000000
    100-40 to 3002 3/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3003 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3005 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3006 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3007 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 3009 7/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30010 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30013 3/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30014 1/8"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    100-40 to 30022"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 3006 1/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 3006 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30010 1/4"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30010 1/4"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30014 1/8"1/4"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30014 1/8"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
    1,000-40 to 30022"3/8"±0.1%3IP68, IP69K
    EN 60751 Class A0000000000000
     
    Cords
    RTDs with Cable
    Image of Product. Front orientation. Contains MultipleImages. RTDs. RTD Probes for Liquids and Gas, RTDs with Cable.
    IP67 Enclosure Rating—IP67-rated probes have plug-in connections that stand up to dust and temporary submersion.
    Probe
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Max. Cable
    Temp., ° F
    Enclosure
    Rating
    Specs. Met
    Each
    4-Pin Micro M12 Plug-In Connection—316 Stainless Steel Probe
    100-145 to 1,1103 7/8"1/4"±0.1%346.5480IP67
    EN 60751 Class A00000000000000
    100-145 to 1,1105 7/8"1/4"±0.1%346.5480IP67
    EN 60751 Class A0000000000000
    100-145 to 1,1107 7/8"1/4"±0.1%346.5480IP67
    EN 60751 Class A0000000000000
    100-145 to 1,1107 7/8"1/4"±0.1%3432480IP67
    EN 60751 Class A0000000000000
    100-145 to 1,1109 7/8"1/4"±0.1%346.5480IP67
    EN 60751 Class A0000000000000
    1,000-55 to 4802"1/4"±0.1%370.5480IP67
    EN 60751 Class A0000000000000
     
    4-Pin Micro M12 Plug-In Connection—316L Stainless Steel Probe
    100-55 to 4801 5/8"3/8"±0.1%396.5480IP67
    EN 60751 Class A0000000000000
    100-40 to 1901 3/4"1/4"±0.1%106.5190IP67
    EN 60751 Class A0000000000000
    100-40 to 1901 3/4"1/4"±0.1%1016190IP67
    EN 60751 Class A0000000000000
    100-40 to 1902"3/8"±0.1%256.5190IP67
    EN 60751 Class A0000000000000
    100-40 to 1902"3/8"±0.1%2516190IP67
    EN 60751 Class A0000000000000
    1,000-40 to 1901 3/4"1/4"±0.1%106.5190IP67
    EN 60751 Class A0000000000000
    1,000-40 to 1902"3/8"±0.1%256.5190IP67
    EN 60751 Class A0000000000000
     

    Bolt-On RTD Probes for Surfaces

    Image of Product. Front orientation. RTDs. Bolt-On RTD Probes for Surfaces, Style A.
    Image of Product. Front orientation. RTDs. Bolt-On RTD Probes for Surfaces, Style B.

    Style A

    Style B

    For reliable temperature readings in high-vibration environments, these RTD probes bolt onto the surface of motors and other equipment.
    Micro M12 Plug Connection
    Image of Product. Front orientation. RTDs. Bolt-On RTD Probes for Surfaces, Style A.

    Style A

    Style A—Style A and B probes are rated IP67 for protection from dust and temporary submersion.
    EN 60751 Class A—Probes that meet EN 60751 adhere to industry standards for accuracy.
    Probe
    Cable
    Style
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Bolt Hole
    Dia.
    Lg.
    Wd.
    Thk.
    Accuracy
    Response
    Time, sec.
    Max.
    Pressure
    Lg.,
    ft.
    Material
    Specs. Met
    Each
    Stainless Steel Probe (IP67)
    A100-40 to 1901/2"2"0.438"0.313"±0.5%15Not Rated6Polyurethane Rubber
    EN 60751 Class A00000000000000
     
    Wire-Ferrule Connection
    Image of Product. Front orientation. RTDs. Bolt-On RTD Probes for Surfaces, Style B.

    Style B

    Style B—Style A and B probes are rated IP67 for protection from dust and temporary submersion.
    EN 60751 Class A—Probes that meet EN 60751 adhere to industry standards for accuracy.
    Probe
    Cable
    Wire
    Style
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Bolt Hole
    Dia.
    Lg.
    Wd.
    Thk.
    Accuracy
    Response
    Time, sec.
    Max.
    Pressure
    Lg.,
    ft.
    Material
    Lead
    Lg.
    AWG
    No. of
    Wires
    Wire Color
    Specs. Met
    Each
    Stainless Steel Probe (IP67)
    B100-40 to 1901/4"1 13/16"0.438"0.313"±0.5%39Not Rated6Polyurethane Rubber
    1"22
    4Brown/Blue/Black/WhiteEN 60751 Class A0000000000000
     

    Adhesive-Back RTD Probes for Surfaces

    About the thickness of a dime, these RTD probes stick to surfaces in tight spaces to measure temperature.
    Wire-Lead Connection
    Image of Product. Front orientation. RTDs. Adhesive-Back RTD Probes for Surfaces.
    EN 60751 Class B—Probes that meet EN 60751 adhere to industry standards for accuracy.
    MIL-STD-108—Probes that meet MIL-STD-108 are submersible, so they can monitor the temperature of water in tanks or containers.
    Probe
    Cable
    Wire
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Wd.
    Thk.
    Accuracy
    Response
    Time, sec.
    Max.
    Pressure
    Lg.,
    ft.
    Material
    Lead
    Lg.
    AWG
    No. of
    Wires
    Wire
    Color
    Specs. Met
    Mil. Spec.
    Each
    Platinum Probe
    100-4 to 3009/16"0.188"0.063"±0.12%1.3Not Rated3Silicone Rubber
    1/2"28
    3Red/WhiteEN 60751 Class BMIL-STD-10800000000000000
    1,000-4 to 3009/16"0.188"0.063"±0.12%1.3Not Rated3Silicone Rubber
    1/2"28
    3Red/WhiteMIL-STD-1080000000000000
     

    Threaded RTD Probes for Surfaces

    Image of Product. Front orientation. RTDs. Threaded RTD Probes for Surfaces, Style A.
    Image of Product. Front orientation. RTDs. Threaded RTD Probes for Surfaces, Style B.

    Style A

    Style B

    Thread these RTD probes into threaded holes in molds, dies, and other objects to measure their temperature.
    Micro M12 Plug Connection
    Image of Product. Front orientation. RTDs. Threaded RTD Probes for Surfaces, Style A.

    Style A

    Style A—Style A and B probes are rated IP67 for protection from dust and temporary submersion.
    EN 60751 Class A—Probes that meet EN 60751 adhere to industry standards for accuracy.
    Probe
    Cable
    Style
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Thread
    Size
    Lg.
    Wd.
    Thk.
    Accuracy
    Response
    Time, sec.
    Max.
    Pressure
    Lg.,
    ft.
    Material
    Specs. Met
    Each
    Stainless Steel Probe (IP67)
    A100-40 to 190M5 × 0.8 mm15/16"0.313"0.188"±0.5%8Not Rated6Polyurethane Rubber
    EN 60751 Class A00000000000000
    A100-40 to 190M6 × 1 mm15/16"0.313"0.188"±0.5%9Not Rated6Polyurethane Rubber
    EN 60751 Class A0000000000000
    A100-20 to 350M5 × 0.8 mm15/16"0.313"0.188"±0.5%8Not Rated6Silicone Rubber
    EN 60751 Class A0000000000000
    A100-20 to 350M6 × 1 mm15/16"0.313"0.188"±0.5%8Not Rated6Silicone Rubber
    EN 60751 Class A0000000000000
     
    Wire-Ferrule Connection
    Image of Product. Front orientation. RTDs. Threaded RTD Probes for Surfaces, Style B.

    Style B

    Style B—Style A and B probes are rated IP67 for protection from dust and temporary submersion.
    EN 60751 Class A—Probes that meet EN 60751 adhere to industry standards for accuracy.
    Probe
    Cable
    Wire
    Style
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Thread Size
    Lg.
    Wd.
    Thk.
    Accuracy
    Response
    Time, sec.
    Max.
    Pressure
    Lg.,
    ft.
    Material
    Lead
    Lg.
    AWG
    No. of
    Wires
    Wire
    Color
    Specs. Met
    Each
    Stainless Steel Probe (IP67)
    B100-20 to 300M12 × 1.5 mm1 3/16"0.375"0.688"±0.5%12Not Rated16Silicone Rubber
    1"22
    4Red/WhiteEN 60751 Class A00000000000000
     

    Threaded RTD Probe Transmitters for Liquids and Gas

    Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in 4-20mA transmitter, these RTDs don’t require a separate signal converter. They have an NPT male probe connection, so they’re ready to screw into thermowells and other fittings on pipe and tanks. Made of 316 or 316L stainless steel, they resist corroding from harsh cleaning chemicals. This stainless steel also protects the RTD sensor inside from impact. They are also often installed in bores to measure the temperature of molds and dies. CE marked, they meet European safety standards.
    4-Pole Micro M12 Plug-In Connection
    Image of Product. Front orientation. Contains Annotated. RTDs. Threaded RTD Probe Transmitters for Liquids and Gas, Micro M12 Connection.
    Fixed Probe—Fixed RTDs can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
    IO Link Communication Protocol—RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet EN 60751 Class A standards for temperature accuracy. UL and C-UL listed, they meet American and Canadian safety standards.
    Probe
    RTD Probe Resistance,
    ohm
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Voltage,
    V DC
    Max. Pressure,
    psi
    Output Current,
    mA
    Communication
    Protocol
    Overall
    Lg.
    Fitting Material
    Temp.,
    ° F
    Each
    NPT Male Probe Connection—Fixed 316L Stainless Steel Probe (IP67, IP68, IP69K)
    1,00011/16"1/4"±0.5%31/2
    18 to 325,8004 to 20IO Link4 1/8"316L Stainless Steel
    0 to 30000000000000000
    1,0001 1/2"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link5"316L Stainless Steel
    0 to 3000000000000000
    1,0003 1/2"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link7"316L Stainless Steel
    0 to 3000000000000000
    1,0005 7/16"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link8 7/8"316L Stainless Steel
    0 to 3000000000000000
     
    Cords

    Threaded RTD Probe Transmitters with Digital Display for Liquids and Gas

    Image of Product. Front orientation. Contains Annotated. RTDs. Threaded RTD Probe Transmitters with Digital Display for Liquids and Gas.
    View temperature readings and adjust settings directly on these RTD probe transmitters. To communicate with programmable logic controllers (PLCs), they have a built-in transmitter with two outputs. One output can send a digital switching signal or use IO Link protocol with the addition of an IO Link controller (not included). The other can send a digital switching signal or a 4-20mA analog signal. The different output options make these RTDs good for a wide range of uses, including operating far away from a controller, taking automated measurements, and providing inputs to switching applications. All have an NPT threaded fitting welded onto the probe, so they’re ready to screw into containers, tanks, and pipes. Probe length is fixed. Made of 316L stainless steel, they are highly corrosion resistant.
    These RTDs meet EN 60751 Class A standards for temperature accuracy. UL Listed, C-UL Listed, and CE Marked, all meet American, Canadian, and European safety standards.
    4-Pole Micro M12 Plug-In Connection
    Probe
    Configurable
    Digital Output
    Configurable
    Analog/Digital Output
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Max. Pressure,
    psi
    No.
    of
    Communication
    Protocol
    Signal
    Output
    No.
    of
    Current,
    mA
    Signal
    Output
    Overall
    Lg.
    Fitting Material
    Sensing Element
    Material
    Specs. Met
    Voltage,
    V DC
    Each
    NPT Male Probe Connection—Fixed 316L Stainless Steel Probe with Plastic Head (IP67)
    1,000-55 to 3001/2"1/4"±0.75%31/4
    5,8001IO LinkNPN/PNP14 to 20NPN/PNP4 7/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 3200000000000000
    1,000-55 to 3001/2"1/4"±0.75%31/2
    4,3501IO LinkNPN/PNP14 to 20NPN/PNP4 7/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
    1,000-55 to 3001 1/4"1/4"±0.75%31/4
    5,8001IO LinkNPN/PNP14 to 20NPN/PNP5 5/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
    1,000-55 to 3001 1/4"1/4"±0.75%31/2
    4,3501IO LinkNPN/PNP14 to 20NPN/PNP5 5/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
    1,000-55 to 3003 1/4"1/4"±0.75%31/2
    3,6251IO LinkNPN/PNP14 to 20NPN/PNP7 5/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
    1,000-55 to 3005 3/16"1/4"±0.75%31/2
    3,6251IO LinkNPN/PNP14 to 20NPN/PNP9 1/2"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
     
    Cords

    RTD Transmitters

    Convert signals from your RTD probe into signal types that data loggers, controllers, and other instruments can read.
    Thread In
    Image of Product. Front orientation. RTD Transmitters. Thread In.
    Thread-in transmitters automatically recognize the probe type, so you don’t need to program them to match. They communicate via IO Link, which lets you change settings, read measurements, and receive error messages remotely when connected to a PLC via an IO Link controller (not included).
    For RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Dia.
    Dp.
    Voltage,
    V DC
    Output Current,
    mA
    Output Voltage,
    V DC
    Communication
    Protocol
    Housing
    Material
    Enclosure
    Rating
    Each
    4-Pole Micro M12
    100/1,000-55 to 3003/4"2"20 to 324 to 20IO LinkPlasticIP67
    000000000000000
    100/1,00032 to 2123/4"2"18 to 320 to 10IO LinkPlasticIP67
    00000000000000
    100/1,00032 to 2123/4"2"20 to 324 to 20IO LinkPlasticIP67
    00000000000000
     
    back to top