Filter by
Mount Type
Number of Wires
For Use With
Environment
Probe Material
Electrical Connection
Maximum Temperature
RTD Sensor Connection
Cable Length
Probe Width
REACH
Minimum Temperature
Response Time
Maximum Pressure
Probe Thickness
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
Military Specification
RoHS
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Certification
About Temperature Sensors
Choose between RTDs and thermocouples based on your application's maximum temperature, duration, and environment.
Adhesive-Back RTD Probes for Surfaces
Wire-Lead Connection
Probe | Cable | Wire | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Probe Resistance, ohm | Temp. Range, ° F | Lg. | Wd. | Thk. | Accuracy | Response Time, sec. | Max. Pressure | Lg., ft. | Material | Lead Lg. | AWG | No. of Wires | Wire Color | Specs. Met | Mil. Spec. | Each | |||
Platinum Probe | |||||||||||||||||||
| 100 | -4 to 300 | 9/16" | 0.188" | 0.063" | ±0.12% | 1.3 | Not Rated | 3 | Silicone Rubber | 1/2" | 28 | 3 | Red/White | EN 60751 Class B | MIL-STD-108 | 6568T51 | 000000 | ||
| 1,000 | -4 to 300 | 9/16" | 0.188" | 0.063" | ±0.12% | 1.3 | Not Rated | 3 | Silicone Rubber | 1/2" | 28 | 3 | Red/White | — | MIL-STD-108 | 6568T52 | 00000 | ||