    50 Products

    Threaded RTD Probes for Liquids and Gas

    With an NPT male probe connection, these RTDs are ready to install in thermowells and other fittings on pipe and tanks. They’re often used to measure temperature in water lines and low-pressure steam lines. Made of stainless steel, these probes resist corrosion and shield the RTD sensor inside from impact. They can also be installed in a bore to measure the temperature of molds and dies.
    Wire-Lead Connection
    Image of Attribute. Front orientation. Contains Annotated. RTDs. Threaded RTD Probes for Liquids and Gas, Fixed Probe.
    Image of Attribute. Front orientation. Contains Annotated. RTDs. Threaded RTD Probes for Liquids and Gas, Spring-Loaded Probe.

    Fixed Probe

    Spring-Loaded Probe

    Fixed Probe—Fixed probes can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
    Spring-Loaded Probe—Spring-loaded probes help ensure accurate readings in vibration-heavy environments. A spring inside the fitting pushes the probe forward, so the probe tip maintains contact with the end of a thermowell. However, these probes aren’t liquid-tight, so they must be installed inside a thermowell or protection sleeve.
    Probe
    Wire
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Fitting Material
    Lead
    Lg.
    AWG
    No. of
    Wires
    Wire
    Color
    Each
    NPT Male Probe Connection—Fixed 304 Stainless Steel Probe
    100-55 to 4003"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White0000000000000
    100-55 to 4004 1/2"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 4006"1/4"±0.12%3.51/2
    316 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 4006 5/8"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White0000000000000
    100-55 to 40012"1/4"±0.12%3.51/2
    316 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 40012 5/8"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White0000000000000
    100-55 to 40018"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 40024"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 40036"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White000000000000
     
    NPT Male Probe Connection—Fixed 316 Stainless Steel Probe
    100-55 to 1,2006"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    3Red/White0000000000000
     
    NPT Male Probe Connection—Spring Loaded 304 Stainless Steel Probe
    100-55 to 4006"1/4"±0.12%101/2
    304 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 40012"1/4"±0.12%101/2
    304 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 40018"1/4"±0.12%101/2
    304 Stainless Steel
    3"24
    3Red/White000000000000
    100-55 to 40024"1/4"±0.12%101/2
    304 Stainless Steel
    3"24
    3Red/White000000000000
     

    Thermocouple and RTD Connection Heads

    Image of Product. Front orientation. Thermocouple and RTD Connection Heads. Screw-On Cap with Retaining Chain.
    Image of Product. Front orientation. Thermocouple and RTD Connection Heads. Hinged Cap.

    Screw-On Cap with

    Retaining Chain

    Hinged Cap

    Attach these heads to your thermocouple or RTD probe to protect wiring from dust and moisture. The removable cap makes it easy to access your wiring when you need. Install an optional terminal block inside the head to keep your wiring organized.
    Hazardous Locations—Hazardous location connection heads are rated for use in Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 environments with flammable gases, combustible dust, and combustible fibers.
    Probe
    Connection
    Conduit
    Connection
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Includes
    Environment
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Aluminum
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining Chain00000000000000
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining ChainCorrosive, Dusty, Hazardous, Outdoor, Washdown, WetNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 4X
    00000000000000
     
    Cast Iron
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining Chain0000000000000
     
    Plastic
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining Chain0000000000000
    1/2
    NPT
    Female3/4
    NPT
    FemaleHinged Cap0000000000000
     
    Stainless Steel
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining Chain00000000000000
    1/2
    NPT
    Female3/4
    NPT
    FemaleScrew-On Cap with Retaining ChainDusty, Hazardous, Washdown, WetNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIC, IIB, IIA
    NEC Zone 21 Groups IIIC, IIIB, IIIA
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    AEx D IIC Gb
    AEx Tb IIIC Db
    Ex D IIC Gb
    Ex Tb IIIC Db
    ATEX II 2 GD Ex Db IIC Gb Ex Tb IIIC Db
    IECEx Ex Db IIC Gb
    IECEx Ex Tb IIIC Db
    IP66
    00000000000000
     

    Threaded RTD Probe Transmitters for Liquids and Gas

    Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in 4-20mA transmitter, these RTDs don’t require a separate signal converter. They have an NPT male probe connection, so they’re ready to screw into thermowells and other fittings on pipe and tanks. Made of 316 or 316L stainless steel, they resist corroding from harsh cleaning chemicals. This stainless steel also protects the RTD sensor inside from impact. They are also often installed in bores to measure the temperature of molds and dies. CE marked, they meet European safety standards.
    Circular DIN Connection
    Image of Product. Side1 orientation. RTDs. Threaded RTD Probe Transmitters for Liquids and Gas, Circular DIN Connection.
    Fixed Probe—Fixed RTDs can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
    Probe
    RTD Probe Resistance,
    ohm
    Lg.
    Dia.
    Accuracy
    Response
    Time
    Probe Connection
    Pipe Size
    Voltage,
    V DC
    Max. Pressure,
    psi
    Output Current,
    mA
    Overall
    Lg.
    Fitting Material
    Choose a Temperature, ° F
    Each
    NPT Male Probe Connection—Fixed 316 Stainless Steel Probe with Plastic Head (IP65)
    1001 3/4"1/4"±0.5%Not Rated1/2
    10 to 307254 to 205 3/4"316 Stainless Steel
    -40 to 120
    ,
    0 to 250
    ,
    50 to 400
    0000000000000
    1003 1/4"1/4"±0.5%Not Rated1/2
    10 to 307254 to 207 1/4"316 Stainless Steel
    -40 to 120
    ,
    0 to 250
    ,
    50 to 400
    000000000000
    1005 1/4"1/4"±0.5%Not Rated1/2
    10 to 307254 to 209 1/4"316 Stainless Steel
    -40 to 120
    ,
    0 to 140
    ,
    50 to 400
    000000000000
    1008 1/4"1/4"±0.5%Not Rated1/2
    10 to 307254 to 2012 1/4"316 Stainless Steel
    -40 to 120
    ,
    0 to 200
    ,
    50 to 400
    000000000000
    10011 1/4"1/4"±0.5%Not Rated1/2
    10 to 307254 to 2015 1/4"316 Stainless Steel
    -40 to 120
    ,
    0 to 250
    ,
    50 to 400
    0000000000000
     
    4-Pole Micro M12 Plug-In Connection
    Image of Product. Front orientation. Contains Annotated. RTDs. Threaded RTD Probe Transmitters for Liquids and Gas, Micro M12 Connection.
    Fixed Probe—Fixed RTDs can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
    IO Link Communication Protocol—RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet EN 60751 Class A standards for temperature accuracy. UL and C-UL listed, they meet American and Canadian safety standards.
    Probe
    RTD Probe Resistance,
    ohm
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Voltage,
    V DC
    Max. Pressure,
    psi
    Output Current,
    mA
    Communication
    Protocol
    Overall
    Lg.
    Fitting Material
    Temp.,
    ° F
    Each
    NPT Male Probe Connection—Fixed 316L Stainless Steel Probe (IP67, IP68, IP69K)
    1,00011/16"1/4"±0.5%31/2
    18 to 325,8004 to 20IO Link4 1/8"316L Stainless Steel
    0 to 30000000000000000
    1,0001 1/2"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link5"316L Stainless Steel
    0 to 3000000000000000
    1,0003 1/2"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link7"316L Stainless Steel
    0 to 3000000000000000
    1,0005 7/16"1/4"±0.5%31/2
    18 to 324,3504 to 20IO Link8 7/8"316L Stainless Steel
    0 to 3000000000000000
     
    Cords
    Screw-Terminal Connection
    Image of Product. Side1 orientation. Contains Annotated. RTDs. Threaded RTD Probe Transmitters for Liquids and Gas, Screw-Terminal Connection.
    RTDs with a screw terminal connection have a cap you can remove to wire the RTD’s terminal block to your application.
    Spring-Loaded Probe—Spring-loaded RTDs are not liquid-tight, so they must be installed in a thermowell or protection tube. The spring inside the fitting pushes the probe against the thermowell to provide an accurate reading.
    RTDs
    Replacement
    RTD Elements
    Probe
    Conduit
    Connection
    RTD Probe Resistance,
    ohm
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Pipe
    Size
    Thread
    Type
    Gender
    Voltage,
    V DC
    Max.
    Pressure
    Output Current,
    mA
    Overall
    Lg.
    Fitting Material
    Choose a Temperature, ° F
    Each
    Each
    NPT Male Probe Connection—Spring Loaded 316 Stainless Steel Probe with Aluminum Head
    1003 3/4"1/4"±0.1%61/2
    3/4
    NPT
    Female10 to 30Not Rated4 to 209"316 Stainless Steel
    0 to 100
    ,
    0 to 200
    ,
    0 to 300
    ,
    0 to 400
    00000000000000000000000000000
    1005 3/4"1/4"±0.1%61/2
    3/4
    NPT
    Female10 to 30Not Rated4 to 2011"316 Stainless Steel
    0 to 100
    ,
    0 to 200
    ,
    0 to 300
    ,
    0 to 400
    000000000000000000000000000
    1008 3/4"1/4"±0.1%61/2
    3/4
    NPT
    Female10 to 30Not Rated4 to 2014"316 Stainless Steel
    0 to 100
    ,
    0 to 200
    ,
    0 to 300
    ,
    0 to 400
    000000000000000000000000000
    10011 3/4"1/4"±0.1%61/2
    3/4
    NPT
    Female10 to 30Not Rated4 to 2017"316 Stainless Steel
    0 to 100
    ,
    0 to 200
    ,
    0 to 300
    ,
    0 to 400
    000000000000000000000000000
     
    Replacement RTD Transmitters

    Dual-Output Threaded RTD Probes for Liquids and Gas

    Send temperature readings to two separate devices—these probes have two RTD sensors inside. For example, one RTD might connect to a data logger while the other connects to a PLC that automates processes based on temperature. These probes have an NPT male threaded fitting, so they’re ready to install in thermowells and other fittings on pipe and tanks. For direct immersion in liquid and gas processes, such as water lines and low-pressure steam lines, the fitting is welded to the sheath to fully enclose the RTDs. The sheath protects the sensors from impact. You can also install these probes in a bore to measure the temperature of molds and dies.
    Wire-Lead Connection
    Image of Product. Front orientation. Contains Annotated. RTDs. Dual-Output Threaded RTD Probes for Liquids and Gas.
    Probe
    Wire
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Fitting Material
    Lead
    Lg.
    AWG
    No. of
    Wires
    Wire
    Color
    Each
    NPT Male Probe Connection—Fixed 304 Stainless Steel Probe
    100-55 to 4006"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    6Red/White00000000000000
    100-55 to 40012"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    6Red/White0000000000000
    100-55 to 40018"1/4"±0.12%101/2
    316 Stainless Steel
    3"24
    6Red/White0000000000000
     

    Threaded RTD Probe Transmitters with Digital Display for Liquids and Gas

    Image of Product. Front orientation. Contains Annotated. RTDs. Threaded RTD Probe Transmitters with Digital Display for Liquids and Gas.
    View temperature readings and adjust settings directly on these RTD probe transmitters. To communicate with programmable logic controllers (PLCs), they have a built-in transmitter with two outputs. One output can send a digital switching signal or use IO Link protocol with the addition of an IO Link controller (not included). The other can send a digital switching signal or a 4-20mA analog signal. The different output options make these RTDs good for a wide range of uses, including operating far away from a controller, taking automated measurements, and providing inputs to switching applications. All have an NPT threaded fitting welded onto the probe, so they’re ready to screw into containers, tanks, and pipes. Probe length is fixed. Made of 316L stainless steel, they are highly corrosion resistant.
    These RTDs meet EN 60751 Class A standards for temperature accuracy. UL Listed, C-UL Listed, and CE Marked, all meet American, Canadian, and European safety standards.
    4-Pole Micro M12 Plug-In Connection
    Probe
    Configurable
    Digital Output
    Configurable
    Analog/Digital Output
    RTD Probe Resistance,
    ohm
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Probe Connection
    Pipe Size
    Max. Pressure,
    psi
    No.
    of
    Communication
    Protocol
    Signal
    Output
    No.
    of
    Current,
    mA
    Signal
    Output
    Overall
    Lg.
    Fitting Material
    Sensing Element
    Material
    Specs. Met
    Voltage,
    V DC
    Each
    NPT Male Probe Connection—Fixed 316L Stainless Steel Probe with Plastic Head (IP67)
    1,000-55 to 3001/2"1/4"±0.75%31/2
    4,3501IO LinkNPN/PNP14 to 20NPN/PNP4 7/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 3200000000000000
    1,000-55 to 3001 1/4"1/4"±0.75%31/2
    4,3501IO LinkNPN/PNP14 to 20NPN/PNP5 5/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
    1,000-55 to 3003 1/4"1/4"±0.75%31/2
    3,6251IO LinkNPN/PNP14 to 20NPN/PNP7 5/8"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
    1,000-55 to 3005 3/16"1/4"±0.75%31/2
    3,6251IO LinkNPN/PNP14 to 20NPN/PNP9 1/2"316L Stainless Steel
    PlatinumEN 60751 Class A18 to 320000000000000
     
    Cords
    back to top