    Harsh Environment Self-Priming Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Harsh Environment Self-Priming Dewatering Pumps.
    This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
    Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Size
    Discharge Size
    Ht.
    Wd.
    Lg.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug with 8 ft. Long Cord
    5 4/5301/4"Not Rated12560 to 1801/44.21/2 NPT Female, 3/4 GHT Male1/2 NPT Female, 3/4 GHT Male9"5 5/8"7 3/8"4381K670000000
     

    Hand-Operated Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Hand-Operated Dewatering Pumps.
    Install these pumps right in your line and engage the lever handle to start pumping. They have few moving parts that can fail for an extended service life. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
    Intake
    Discharge
    Overall
    Max. Flow Rate,
    fl oz/stroke
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    For Hose
    ID
    Connection
    Gender
    For Hose
    ID
    Connection
    Gender
    Ht.
    Wd.
    Lg.
    Each
    15351/8"100,00035 to 1501"Barbed
    Male1"Barbed
    Male4 3/8"4 3/8"12 3/4"4332K31000000
    17351/8"100,00035 to 1501 1/2"Barbed
    Male1 1/2"Barbed
    Male4 1/4"4 3/8"13 1/8"4332K33000000
     

    Submersible Pumps for Salt Water

    Image of Product. Front orientation. Submersible Pumps. Submersible Pumps for Salt Water.
    Circulate salt water in submerged and open-air applications. These pumps use magnets to turn the impellers so there is no shaft seal to wear out. They must be wired to a plug (not included) to activate. Do not run dry.
    Max. Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    @ 1 Ft.
    of Head
    @ 5 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    53.81335 to 1301/500.93/8 × 3/4NPT × NPTFemale × Male1/4
    NPT
    Male64 1/8"6 1/8"4 7/8"99845K460000000
    8.581935 to 1301/2023/4
    NPT
    Female1/2
    NPT
    Male64 7/8"7 3/8"4 3/4"99845K48000000
     

    Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Stainless Steel Circulation Pumps for Chemicals.
    A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    322210441001/8"501/35.6 amp/2.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K8100000004320K110000000
    32323220621003/32"503/410.6 amp/5.3 amp1 1/4 Female NPT3/4 Female NPT16"9"7 3/4"4320K84000000004320K14000000
    363022541001/8"501/27.6 amp/3.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K820000004320K12000000
    38332718591001/8"503/410.6 amp/5.3 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K830000004320K13000000
    90826335601003/32"50112.6 amp/6.3 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K95000000004320K14000000
     
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire
    754715341003/16"5012.9 amp/1.4 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K96000000004320K11000000
    95805520491003/16"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K88000000004320K13000000
    110100805828701003/32"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K87000000004320K15000000
    11555521003/16"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K91000000004320K16000000
    1309060821003/32"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K92000000004320K17000000
    1309555791003/16"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K94000000004320K19000000
    1408555881003/32"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K93000000004320K18000000
     
    Repair Kits

    Compact Dewatering Pumps

    Also known as bilge pumps, these remove fresh and salt water from spots where other pumps don’t fit. They have an internal sensor, so they turn on when they detect water and turn off when the water is removed. Pumps are fully submersible. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
    12V DC, Single Phase
    Image of Product. Front orientation. Dewatering Pumps. Compact Dewatering Pumps, 12V DC, Single Phase.
    Pumps for 12 volts DC work with 12-volt batteries.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Removes
    Water Down To
    Temp. Range,
    ° F
    Sensor Time
    Interval, min.
    Power
    Current,
    amp
    For Tube
    ID
    Gender
    Dia.
    Ht.
    Each
    ABS Housing
     
    Hardwire with 2 ft. Long Cord
    51111/4"30 to 1402.5Not Rated1.63/4"Male3"4"3022K11000000
    103101/4"30 to 1402.5Not Rated3.71", 1 1/8"Male3"5"3022K21000000
     
    120V AC, Single Phase
    Image of Product. Front orientation. Dewatering Pumps. Compact Dewatering Pumps, 120V AC, Single Phase.
    Pumps for 120 volts AC are for use in debris-free water.
    Max. Flow
    Rate, gpm
    Discharge
    Overall
    @ 5 Ft.
    of Head
    @ 10 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Removes
    Water Down To
    Temp. Range,
    ° F
    Sensor Time
    Interval, min.
    Power
    Current
    Pipe
    Size
    Thread
    Type
    Gender
    Dia.
    Ht.
    Includes
    Each
    ABS Housing
     
    Plug with 8 ft. Long Cord
    2013181"40 to 1402.5Not RatedNot Rated1
    NPT
    Male5"8"Garden Hose Adapter3022K420000000
     
    Plug with 24 ft. Long Cord
    2013181"40 to 1402.5Not RatedNot Rated1
    NPT
    Male5"8"Garden Hose Adapter3022K43000000
     

    Corrosion-Resistant Gasoline-Powered Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Corrosion-Resistant Gasoline-Powered Dewatering Pumps.
    Built with high-chromium stainless steel components, this pump stands up to salt water with up to 25% sand by volume and resists wear caused by abrasive particles. Fill the fuel tank with gasoline to remove water at sites without power. Pump is self-priming, which means it creates a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. Pump has a pull-start engine. It is not submersible.
    Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
    Cannot Be Sold to Canada—This pump cannot be sold to Canada due to import regulations.
    Max. Flow Rate, gpm
    Intake
    Discharge
    Overall
    @ 20 Ft.
    of Head
    @ 50 Ft.
    of Head
    @ 70 Ft.
    of Head
    @ 90 Ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To, ft.
    Tank Cap.,
    qt.
    Temp. Range,
    ° F
    Power,
    hp
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Pipe
    Size
    Thread
    Type
    Connection
    Gender
    Ht.
    Wd.
    Lg.
    Cannot Be
    Sold To
    Each
    1531259358981/2"103.840 to 16052
    NPT
    ThreadedFemale2
    NPT
    ThreadedFemale20"20"25"Canada3066K44000000000
     
    Accessories for Dewatering Pumps

    Self-Priming Circulation Pumps without Motor for Oil

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Oil.
    Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Ht.
    Lg.
    Wd.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    11.55021Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT5/8"1 1/8"1 15/16"3 13/16"4 1/2"4 1/8"4281K240000000
    255026Not Rated50 to 1803/41 Female NPT1 Female NPT5/8"2 1/4"1 7/8"3 9/16"6 3/8"4 3/4"4281K26000000
     
    Repair Kits

    Self-Priming Circulation Pumps without Motor for Water

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Water.
    Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Overall
    Shaft
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Ht.
    Lg.
    Wd.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    136026Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT3 13/16"4 1/2"4 1/8"5/8"1 1/8"1 15/16"4281K210000000
    27.96026Not Rated50 to 1803/41 Female NPT1 Female NPT3 9/16"6 3/8"4 3/4"5/8"2 1/4"1 7/8"4281K23000000
     
    Repair Kits

    Extended-Life Plastic Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Plastic Circulation Pumps for Chemicals.
    These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Pipe Size
    (Gender)
    Discharge Pipe
    Size (Gender)
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    232010351/42.07 amp/4.14 amp1 (Female)1 (Female)14 3/8"5 1/8"7 7/8"3068N110000000003068N11200000003068N111000000
    262612351/33.24 amp/6.84 amp1 (Female)1 (Female)16 5/16"6 1/8"8 3/16"3068N12000000003068N1220000003068N12100000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    5757533025451/21.1 amp/2.2 amp1 1/2 (Female)1 1/2 (Female)18 3/8"8 7/8"11 5/16"3068N13000000003068N1320000003068N13100000
    9090847461497011.5 amp/3 amp1 1/2 (Female)1 1/2 (Female)18 7/8"6 5/16"10 1/8"3068N14000000003068N1420000003068N14100000
     
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    38363227214951/27.5 amp/3.7 amp1 (Female)3/4 (Male)15 1/2"9"8 1/4"3068N19000000003068N2220000003068N2210000
    535346403323260519.2 amp/4.6 amp to 6.3 amp1 1/2 (Female)1 (Male)17 13/16"9 1/8"8 3/16"3068N18000000003068N2320000003068N23100000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    3031262074151/31.2 amp to 1.3 amp/0.6 amp1 (Female)3/4 (Male)15 1/16"9 1/4"7 3/8"3068N21000000003068N2120000003068N2210000
    38363227214951/20.8 amp to 1.7 amp/1.7 amp1 (Female)3/4 (Male)15 1/16"9 1/8"7 3/16"3068N22000000003068N2220000003068N2210000
    535346403323260512.2 amp to 3.3 amp/1.1 amp1 1/2 (Female)1 (Male)16 9/16"9 1/8"7 3/8"3068N23000000003068N2320000003068N23100000
    8282828180716185524.8 amp to 4.9 amp/2.4 amp2 (Male)1 1/2 (Male)20 11/16"10 3/8"10"3068N24000000003068N242000000003068N24100000
    1201201201201121059295537.8 amp to 8 amp/3.9 amp2 (Male)1 1/2 (Male)24 3/8"11 1/2"10 1/2"3068N26000000003068N252000000003068N25100000
     