Choosing a Proximity Switch
More
Choosing an Electrical Switch
More
DC Metallic-Object Proximity Switches


Nano
M8 Plug
Also known as inductive proximity switches, these detect metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the target material. The distance listed is for mild steel. They’re often used with programmable logic controllers (PLCs) and produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included).
Flush switches, also known as embeddable or shielded switches, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting switches at close range and can be mounted close together without causing interference.
Switches with a plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
IP65 rated switches are protected from washdowns. IP67 and IP68 rated switches are protected from temporary submersion.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
Switches | Cables with Sockets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | Lg., mm | Circuit Protection | Temperature Range, °F | Each | Each | ||
Nickel-Plated Brass Housing with Plastic Face (IP65 and IP67) | ||||||||||||
Flush with 3-Pole Nano M8 Plug | ||||||||||||
1 Off (Normally Open) | 8 | 2 | PNP | 10V DC-30V DC | 100mA | 50 | Overload Reverse Polarity Short Circuit | -10° to 155° | 00000000 | 000000 | 0000000 | 000000 |
Flat-Body AC/DC Metallic-Object Proximity Switches

Mount these flat inductive switches to a base or rail to remotely detect metallic objects in wet and dirty environments. Because these switches have a flat body and long sensing range, they are ideal for noncontact detection of metal objects in position sensing and part presence applications. Use them where cylindrical switches will not fit. Sensing distance is based on the target material. The distance listed is for mild steel. All switches meet American, Canadian, and European safety standards.
Projecting switches are also known as non-embeddable or unshielded switches. They must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches of similar size.
IP65 rated switches protect against dust and low-pressure jets of water.
Switch Starting Position | Max. Sensing Distance, mm | Input Voltage | Current Output | Length, mm | Width, mm | Height, mm | For Cable OD | Features | Temp. Range, °F | Environmental Rating | Each | |
Plastic Housing | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Projecting with Screw Terminals | ||||||||||||
1 Off (Normally Open) | 60 | 20V AC-250V AC/20V DC-250V DC | 250 mA | 105 | 80 | 40 | 0.27"-0.51" | LED Indicators | -10° to 155° | IP65 | 00000000 | 0000000 |
Rotatable AC/DC Metallic-Object Proximity Switches
Rotate the face on these switches five different directions for easy installation and positioning—they work with both AC and DC inputs. Unlike traditional limit switches that have actuators, these noncontact switches adjust for front, top, bottom, left, or right facing objects. They have inductive sensors to detect objects even if they’re covered by water, oil, dirt, or a surface finish, making them good for conveyor systems and bin filing operations in refineries, mills, and other challenging environments. Maximum sensing distance is based on the object's material; the distance listed is for mild steel.
They are UL and C-UL listed, as well as CE marked, to meet American, Canadian, and European Union safety standards. Some are also CSA certified.
Flush switches, also called embeddable and shielded switches, are more accurate than projecting switches at close range. They also won’t interfere with each other’s signals when installed close together. The face mounts evenly with any material, including metal.
Projecting switches, also known as non-embeddable and unshielded switches, sense objects farther away than flush switches. To work properly, the area around the face must be metal free.
All have 3-pole micro connectors to easily connect and disconnect.
IP-rated, they all seal out dust and debris. IP 65-rated switches protect against low-pressure washdowns, such as water from a garden hose.




Switch Starting Position | Max. Sensing Distance, mm | No. of Sensing Positions | Signal Output Type | Input Voltage Range | Current Output | Lg., mm | Wd., mm | Ht., mm | For Cable OD | Features | Temp. Range, °F | Specifications Met | Each | |
Plastic Housing with Plastic Face (IP65-Rated) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flush with 1/2" Screw Terminals | ||||||||||||||
1 Off (Normally Open) and 1 On (Normally Closed) | 15 | 5 | PNP, NPN | 20V AC-250V AC/20V DC-250V DC | 250mA | 120 | 40 | 40 | 0.27"-0.51" | LED Status Indicator | -10° to 150° | UL Listed, C-UL Listed, CSA Certified, CE Marked | 00000000 | 0000000 |
Projecting with 1/2" Screw Terminals | ||||||||||||||
1 Off (Normally Open) and 1 On (Normally Closed) | 20 | 5 | PNP, NPN | 20V AC-250V AC/20V DC-250V DC | 250mA | 120 | 40 | 40 | 0.27"-0.51" | LED Status Indicator | -10° to 150° | UL Listed, C-UL Listed, CSA Certified, CE Marked | 00000000 | 000000 |
Harsh Environment Photoelectric Switches


Nano
M8 Plug

Micro
M12 Plug
Rated IP69K, these switches can withstand high-pressure and high-temperature washdowns. They detect the presence or absence of an object with a light beam moving at high speeds and produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included).
IP67 and IP68 rated switches are protected from temporary submersion.
Direct sensing switches detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
Receiver switches detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing and reflector switches.
Reflector switches detect an object when it passes between the switch and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing switches.
Switches with a plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
Color immune switches have the same sensing distance for dark and light colored objects.
Light Beam Switch Operation | Max. Sensing Distance | Input Voltage | Current Output | Signal Output Type | Lg. | Ht. | Wd. | Housing Material | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
With Wire Leads—Color Immune | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Direct Sensing Switch with Visible Light Beam | |||||||||||||
On When Object Absent, On When Object Present | 8" | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 0000000 |
On When Object Absent, On When Object Present | 8" | 10V DC-30V DC | 100mA | NPN | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 |
Receiver Switch with Visible Light Beam | |||||||||||||
On When Object Absent, On When Object Present | 32.5ft. | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 |
Reflector Switch with Visible Light Beam | |||||||||||||
On When Object Absent, On When Object Present | 16ft. | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 |
On When Object Absent, On When Object Present | 16ft. | 10V DC-30V DC | 100mA | NPN | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 |
Switches | Cables with Socket | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Beam Switch Operation | Max. Sensing Distance | Input Voltage | Current Output | Signal Output Type | Lg. | Ht. | Wd. | Housing Material | Temperature Range, °F | Environmental Rating | Specifications Met | Each | Each | ||
With 3-Pole Nano M8 Plug—Color Immune | |||||||||||||||
Direct Sensing Switch with Visible Light Beam | |||||||||||||||
On When Object Absent, On When Object Present | 8" | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, C-UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 0000000 | 0000000 | 000000 |
On When Object Absent, On When Object Present | 8" | 10V DC-30V DC | 100mA | NPN | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, C-UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
Reflector Switch with Visible Light Beam | |||||||||||||||
On When Object Absent, On When Object Present | 16ft. | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, C-UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
With 4-Pole Micro M12 Plug—Color Immune | |||||||||||||||
Direct Sensing Switch with Visible Light Beam | |||||||||||||||
On When Object Absent, On When Object Present | 8" | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
On When Object Absent, On When Object Present | 8" | 10V DC-30V DC | 100mA | NPN | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
Receiver Switch with Visible Light Beam | |||||||||||||||
On When Object Absent, On When Object Present | 32.5ft. | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
Reflector Switch with Visible Light Beam | |||||||||||||||
On When Object Absent, On When Object Present | 16ft. | 10V DC-30V DC | 100mA | PNP | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
On When Object Absent, On When Object Present | 16ft. | 10V DC-30V DC | 100mA | NPN | 13/16" | 1 3/8" | 1/2" | Stainless Steel | 15° to 175° | IP65, IP68, IP69K | UL Listed, CE Marked, EN 60947-5-2 | 0000000 | 000000 | 0000000 | 00000 |
Miniature Photoelectric Switches
About half the size of standard photoelectric switches, these switches are good for use in tight spaces. They detect objects moving at high speeds with a light beam. They produce PNP or NPN signal output; to determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included).
Direct sensing switches detect objects when light reflects back from the object. The transmitter and receiver are in the same housing.
Receiver switches detect an object’s presence when they break the light beam between the transmitter and the receiver (both included).
Adjustable switches let you increase the intensity of the light beam to better detect shiny or translucent objects.
IP65 rated switches protect against dust and light rinses.

Light Beam Switch Operation | Max. Sensing Distance | Input Voltage | Current Output | Signal Output Type | Lg., mm | Dia., mm | Housing Material | Temp. Range, °F | Each | |
Direct Sensing Switch with Wire Leads | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Infrared Light Beam—Adjustable (IP65) | ||||||||||
On When Object Present | 2" | 12V DC-24V DC | 80mA | PNP | 29.1 | 11 | Plastic | -10° to 130° | 0000000 | 0000000 |
On When Object Present | 2" | 12V DC-24V DC | 80mA | NPN | 29.1 | 11 | Plastic | -10° to 130° | 0000000 | 000000 |
Receiver Switch with Wire Leads | ||||||||||
Visible Light Beam—Adjustable (IP65) | ||||||||||
On When Object Present | 39" | 12V DC-24V DC | 80mA | PNP | 26.2 | 10 | Plastic | -10° to 130° | 0000000 | 000000 |
On When Object Present | 39" | 12V DC-24V DC | 80mA | NPN | 26.2 | 10 | Plastic | -10° to 130° | 0000000 | 000000 |
Safety Laser Scanners
Monitor a wide area around dangerous machinery. If a person or object gets too close, these scanners signal your relay or controller to either trigger a warning or shut down the machinery. For example, they can slow a robotic arm if someone comes within 20 ft., then stop it completely if they come within 10 ft. You can also set these scanners to respond only when they detect objects of a certain size. Since they continuously monitor 275°, they cover a much wider area than light beam safety barrier switches.
These scanners have a dedicated safety output for triggering emergency stops, and three inputs/outputs that you can configure. The safety output sends two duplicate signals at the same time—also called redundant signals—so even if one fails, the other will stop your equipment. Wire this output to safety relays or safety terminals on a controller. The inputs/outputs can be configured to set off warnings or adjust the scanner’s behavior. When used as outputs, they can send a signal to flash a light, sound an alarm, or slow a machine. When used as inputs, they can signal the scanner to ignore robot arms or other expected objects, while still scanning for people and unexpected objects.
Download free software onto a computer running Windows to set the monitoring distance, the size of the objects you want to detect, and the function of the inputs/outputs. You can also save up to six different configurations on the scanner itself.
Rated IP65, these switches are sealed to keep out dust and low-pressure jets of water. They’re UL and C-UL listed, CE marked, and TUV SUD certified, so they meet U.S. and international safety standards. They also meet EN, ISO, and IEC standards for performance and safety.
You’ll need a power/input/output cable to connect the scanner to your power supply, controller, or relay. Use an ethernet cord to connect the scanner to your computer for programming.
Mount these scanners to a flat surface using holes on the back. Add a mounting bracket to tilt the scanner toward the area you want to monitor. To shield the top of your scanner from falling objects and collisions, mount a protective bracket onto the mounting bracket.


Safety Sensing Distance Range | No. of Safety Outputs | Configurable Input/Output Sensing Distance Range | No. of Configurable Inputs/Outputs | Min. Object Size Detected | Signal Input/Output Type | Input Voltage | Max. Sensing Angle | Wd. | Ht. | Dp. | Housing Material | Housing Color | Each | |
8-Pole M12 Socket Connection | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2"-9.8 ft. | 1 | 2"-131.2 ft. | 3 | 1.2" | PNP | 24V DC | 275° | 4" | 6" | 4.4" | Powder-Coated Aluminum | Yellow | 0000000 | 000000000 |
2"-18 ft. | 1 | 2"-131.2 ft. | 3 | 1.2" | PNP | 24V DC | 275° | 4" | 6" | 4.4" | Powder-Coated Aluminum | Yellow | 0000000 | 00000000 |

Number of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Shielding | Shield Type | Temp. Range, °F | Cord Insulation Material | Color | Each | |
9 1/2 ft. Lg. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
D-Coded—Ethernet Cable Category 5E | ||||||||||
4 | 100 | 24 | 0.26" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 000000 |
32 1/2 ft. Lg. | ||||||||||
D-Coded—Ethernet Cable Category 5E | ||||||||||
4 | 100 | 24 | 0.26" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 000000 |

Material | Mounting Fasteners Included | Each | |
Zinc-Plated Steel | Yes | 0000000 | 000000 |
Roller-Conveyor-Mount Photoelectric Switches


with Solenoid Valve
and Cable Lead

Solenoid Valve
and Cable Lead
A slim design and a light beam that’s angled upwards allow these switches to sense objects from between conveyor rollers. Because they’re photoelectric, they can detect objects that are moving quickly. All are adjustable, so you can increase the intensity of the light beam to sense shiny or translucent objects. These switches have an M12 connection to quickly connect and disconnect from your switch. Add cables (sold separately) to switches with a plug to wire them into your setup.
Switches with an NFC connection can be programmed and calibrated through a free app on your smartphone. This way, you can leave the switch installed while calibrating it.
Direct sensing switches project light onto an object and then detect the reflection to actuate. The transmitter and receiver are in the same housing, so these switches fit in tight spaces. They require a quick-clip mounting bracket (sold separately).
Reflector switches detect an object when it passes between the switch and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing switches. They can be mounted with an L-shaped mounting bracket (sold separately).
IP65 switches protect against dust and splashing water.Switches with a solenoid valve allow you to control air-powered conveyor drives directly from the switch.
Switches with a conveyor on/off switch allow you to control when conveyors start and stop—no need for a separate controller.
Switches | Mounting Brackets | Reflectors | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Beam Switch Operation | Max. Sensing Distance, ft. | Input Voltage | Current Output | Signal Output Type | Lg. | Wd. | Ht. | Cable Lead Lg., ft. | Features | Each | Each | Each | |||
With 4-Pole Micro M12 Socket | |||||||||||||||
Direct Sensing Switch with Infrared Light Beam (IP65) | |||||||||||||||
On When Object Absent | 2.5 | 21V DC-30V DC | 200mA | PNP | 1 13/16" | 11/16" | 3 7/8" | 6 1/2 | Solenoid Valve, Conveyor On/Off Switch | 00000000 | 0000000 | 00000000 | 000000 | 000000 | 00 |
Reflector Switch with Visible Light Beam (IP65) | |||||||||||||||
On When Object Present | 21 | 18V DC-30V DC | 200mA | PNP | 1 13/16" | 11/16" | 3 7/8" | 4 1/2 | Solenoid Valve, Conveyor On/Off Switch | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 000000 |
With 4-Pole Micro M12 Socket and NFC Connection | |||||||||||||||
Direct Sensing Switch with Infrared Light Beam (IP65) | |||||||||||||||
On When Object Present | 2.5 | 21V DC-30V DC | 200mA | PNP | 1 13/16" | 11/16" | 3 7/8" | 6 1/2 | Solenoid Valve, Conveyor On/Off Switch | 00000000 | 000000 | 00000000 | 00000 | 000000 | 00 |
DC Universal-Object Proximity Switches





Micro
M12 Plug

Micro
M12 Plug
Also known as capacitive proximity switches, these remotely sense both metallic and nonmetallic objects, but their strength is in sensing materials such as plastic, ceramic, and clear targets. Sensing distance is based on the type of material being sensed. The distance listed is for mild steel. Often used with programmable logic controllers (PLCs), they produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included).
Mount flush switches so that the sensor face is level with the surface of your material. Also known as embeddable or shielded switches, they’re more accurate than projecting switches at close range and can be mounted close together on any surface without causing interference. Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches with the same diameter.
Switches with a plug connect to cables with socket (sold separately), allowing you to quickly connect and disconnect the switch.
Switches with IO link can be configured remotely when connected to a PLC, a human-machine interface (HMI), or a computer.
Switches with PNP/NPN signal output automatically produce the type of signal output that is needed based on the device they are connected to.
IP65 switches are protected from washdowns. Switches rated IP67 are protected from temporary submersion. Choose IP69K switches to withstand high-pressure, high-temperature washdowns.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Circuit Protection | Cable Lead Lg., ft. | Temp. Range, °F | Environmental Rating | Each | |
Plastic Housing with Plastic Face | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Projecting with Wire Leads | |||||||||||||
1 Off (Normally Open) or 1 On (Normally Closed) | 30 | 15 | PNP | 10V DC-36V DC | 250mA | 3 | 99 | Overload Reverse Polarity Short Circuit | 6 1/2 | -10° to 155° | IP65 | 00000000 | 0000000 |
1 Off (Normally Open) or 1 On (Normally Closed) | 30 | 15 | NPN | 10V DC-36V DC | 250mA | 3 | 99 | Overload Reverse Polarity Short Circuit | 6 1/2 | -10° to 155° | IP65 | 00000000 | 000000 |
Stainless Steel Housing with Plastic Face | |||||||||||||
Flush with Wire Leads | |||||||||||||
1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-36V DC | 100mA | 3 | 69 | Reverse Polarity Short Circuit | 6 1/2 | -10° to 155° | IP65 | 0000000 | 000000 |
1 Off (Normally Open) | 12 | 4 | NPN | 10V DC-36V DC | 100mA | 3 | 69 | Reverse Polarity Short Circuit | 6 1/2 | -10° to 155° | IP65 | 0000000 | 000000 |
Switches | Cables with Sockets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | Lg., mm | Circuit Protection | Cable Lead Lg. | Temp. Range, °F | Environmental Rating | Each | Each | ||
Plastic Housing with Plastic Face | ||||||||||||||
Projecting with 3-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) or 1 On (Normally Closed) | 30 | 15 | PNP | 10V DC-36V DC | 250mA | 99 | Overload Reverse Polarity Short Circuit | 4" | -10° to 175° | IP65 | 00000000 | 0000000 | 0000000 | 000000 |
Projecting with 4-Pole Micro M12 Plug and IO Link | ||||||||||||||
1 Off (Normally Open) or 1 On (Normally Closed) | 18 | 12 | PNP/NPN | 10V DC-36V DC | 200mA | 87 | Overload Reverse Polarity Short Circuit | __ | -10° to 175° | IP65, IP67 | 00000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) or 1 On (Normally Closed) | 18 | 30 | PNP | 10V DC-30V DC | 200mA | 92.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 175° | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) or 1 On (Normally Closed) | 30 | 20 | PNP/NPN | 10V DC-36V DC | 200mA | 90 | Overload Reverse Polarity Short Circuit | __ | -10° to 175° | IP65, IP67 | 00000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) or 1 On (Normally Closed) | 30 | 40 | PNP | 10V DC-30V DC | 200mA | 92 | Overload Reverse Polarity Short Circuit | __ | -10° to 175° | IP65, IP67, IP69K | 00000000 | 000000 | 0000000 | 00000 |
Stainless Steel Housing with Plastic Face | ||||||||||||||
Flush with 3-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-36V DC | 100mA | 59.8 | Reverse Polarity Short Circuit | __ | -10° to 155° | IP65 | 0000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) | 12 | 4 | NPN | 10V DC-36V DC | 100mA | 59.8 | Reverse Polarity Short Circuit | __ | -10° to 155° | IP65 | 0000000 | 000000 | 0000000 | 00000 |
Projecting with 3-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) | 12 | 8 | PNP | 10V DC-36V DC | 100mA | 61.2 | Reverse Polarity Short Circuit | __ | -10° to 155° | IP65 | 0000000 | 000000 | 0000000 | 00000 |
AC/DC Universal-Object Proximity Switches



Switches accept both AC and DC input voltage. Also known as capacitive proximity switches, they remotely sense both metallic and nonmetallic objects but their strength is in sensing materials such as plastic, ceramic, and clear targets. All are projecting switches, and must be mounted with the area around the sensor face free of metal.
Switches with a plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
IP65 rated switches are protected from washdowns.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
Proximity Switches | Cables with Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Cable Lead Lg. | Temperature Range, °F | Environmental Rating | Each | Each | ||
Plastic Housing with Plastic Face | |||||||||||||
With Wire Leads | |||||||||||||
1 Off (Normally Open) | 30 | 15 | 20V AC-250V AC/20V DC-250V DC | 200mA, 100mA | 2 | 99 | 6 1/2ft. | -10° to 155° | IP65 | 00000000 | 0000000 | 000000 | 00 |
1 On (Normally Closed) | 30 | 15 | 20V AC-250V AC/20V DC-250V DC | 200mA, 100mA | 2 | 99 | 6 1/2ft. | -10° to 155° | IP65 | 00000000 | 000000 | 000000 | 00 |
With 2-Pole Micro 1/2"-20 UNF Plug | |||||||||||||
1 Off (Normally Open) | 30 | 15 | 20V AC-250V AC/20V DC-250V DC | 200mA, 200mA | __ | 99 | 4" | -10° to 155° | IP65 | 0000000 | 000000 | 0000000 | 000000 |
1 On (Normally Closed) | 30 | 15 | 20V AC-250V AC/20V DC-250V DC | 200mA, 200mA | __ | 99 | 4" | -10° to 155° | IP65 | 00000000 | 000000 | 0000000 | 00000 |
Fixture-Mount Motion-Sensing Light Controls
Detect motion near your light fixture to turn lights on and off. Compared to switch-mount motion controls that detect from a single wall, these controls have a better view of the entire space since they sense motion from above. Also known as occupancy sensors, these controls have an infrared sensor that activates when it detects a change in heat. To work properly, they need an unobstructed view of your space. All have a time delay to turn lights off after a set time. Rated IP65, these controls are protected from washdowns.
These light controls monitor motion in a full circle for coverage in all directions. Those that cover 7,690 sq. ft. have lenses that can be swapped out to limit where they sense. Half-circle sensing lenses are best for concentrating coverage to a certain part of a room, such as a workstation or an entrance. Narrow sensing lenses are best for the end of aisles in spaces with high ceilings like those in warehouses and factories.

Light Controls | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit | Mounting Extensions | |||||||||||||||||||
Coverage, sq. ft. | Features | Sensing Spread | No. of Circuits Controlled | Input Voltage | Wattage | Max. Mounting Ht., ft. | Color | Housing Material | Connection Gender | Trade Size | Thread Type | Ht. | Dia. | Dp. | Wire Connection Type | Specifications Met | Each | Each | ||
1,000 | __ | Full Circle | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 40 | White | Plastic | Male | 1/2 | NPT | 1 15/16" | 4 1/16" | 4 1/2" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 | 000000 | 00 |
1,200 | __ | Full Circle | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 20 | White | Plastic | Male | 1/2 | NPT | 1 15/16" | 4 1/16" | 4 1/2" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 000000 | 000000 | 00 |
7,690 | __ | Full Circle | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 45 | White | Plastic | Male | 1/2 | NPT | 2 1/8" | 4" | 4 3/4" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 000000 | 0000000 | 000000 |
7,690 | Dimmer Switch | Full Circle | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 45 | White | Plastic | Male | 1/2 | NPT | 2 1/8" | 4" | 4 3/4" | Wire Leads | UL Listed, C-UL Listed | 00000000 | 000000 | 000000 | 00 |
Fingerprint Switches


Use fingerprints to confirm the identity of personnel before granting access to secure areas or equipment. Switches light up green to indicate that they have accepted the fingerprint and are sending an output signal. The front faces of the switches meet NEMA 12 and IP65. The rear faces of the switches meet IP20.
Covers (sold separately) have an adhesive-back hinge, so you can stick them on to your switch. Keep the cover flipped down to protect the switch’s sensor from dust and debris.
Switches | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Leads | Covers | |||||||||||||
No. of Users | No. of Fingerprints per User | Switch Action | Actuator Color | Signal Output Type | Current Output, mA | Input Voltage | Bulb Voltage | Dp. Behind Panel | No. of | Ga. | Each | Each | ||
Plastic Actuator with Wire Leads | ||||||||||||||
For 22 mm Panel Cutout Dia. | ||||||||||||||
200 | 2 | Springs Back (Momentary) | Black | PNP | 200 | 20V DC-30V DC | 3.3V DC | 1 9/16" | 3 | 22 | 0000000 | 0000000 | 00000000 | 000000 |
Plastic Actuator with 3-Pole Micro M12 Plug | ||||||||||||||
For 22 mm Panel Cutout Dia. | ||||||||||||||
200 | 2 | Springs Back (Momentary) | Black | PNP | 200 | 20V DC-30V DC | 3.3V DC | 1 9/16" | __ | __ | 0000000 | 000000 | 00000000 | 00000 |
Finger-Touch Switches

The light touch of a finger turns circuits on and off without pressing down a contact. Program these switches to fit your application—control their color, pattern, and sensitivity. Change the color to show different process statuses. For more visibility, change the intensity of the color or choose a light pattern. These switches can flash, rotate, and show other patterns, all at speeds you can control. To change how much force they need to actuate, alter the sensitivity. With a high sensitivity, they’ll actuate even if you’re wearing gloves. With a low sensitivity, they’re more resistant to accidental actuation.
To program your switch, download the free Banner Pro Editor Software. You’ll need a switch programming kit (sold separately) to connect your switch to the software.
Switches with an audible alarm can be programmed to 12 different tones ranging from sirens to melodies.

Dia. | Ht. | Switch Starting Position | Switch Action | Message (Actuator Color) | Signal Type | Configurable Light Settings | Configurable Alarm Settings | Current Output, mA | Input Voltage Range | Dp. Behind Panel | Environmental Rating | Each | ||
Polycarbonate Plastic Base with 8-Pole Micro M12 Plug and PNP/NPN Output | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For 30 mm Panel Cutout Dia. | ||||||||||||||
B | 2 3/4" | 1 3/16" | 1 Off (Normally Open) | Springs Back (Momentary) | Touch Activation Symbol (Amber, Blue, Cyan, Green, Lime Green, Magenta, Orange, Red, Rose, Sky Blue, Spring Green, Violet, White, Yellow) | Light, Audible Alarm | Color, Intensity, Pattern, Speed | Tone, Volume | 100 | 12V DC-30V DC | 2.22" | IP65 | 00000000 | 0000000 |
B | 2 3/4" | 1 3/16" | 1 Off (Normally Open) | Stays Switched (Maintained) | Touch Activation Symbol (Amber, Blue, Cyan, Green, Lime Green, Magenta, Orange, Red, Rose, Sky Blue, Spring Green, Violet, White, Yellow) | Light, Audible Alarm | Color, Intensity, Pattern, Speed | Tone, Volume | 100 | 12V DC-30V DC | 2.22" | IP65 | 00000000 | 000000 |

USB | |||||||
---|---|---|---|---|---|---|---|
Input Voltage | Connection Type | Standard | Power Plug Type | Operating System Compatibility | Includes | Each | |
24V DC | A | 2.0 | Two Prong | Windows 7 or Later | Micro M12 Cords, Power Supply, Splitter, Wire Splicing Connectors | 00000000 | 0000000 |
Two-Hand Safety Switches
It takes two hands to activate these switches, minimizing the risk of accidental equipment start up. They have an emergency stop push-button to immediately cut power. They’re rated IP65 for protection from low-pressure washdowns.
Switches with finger-touch actuators turn circuits on and off with a light touch, even when wearing gloves. An infrared sensor detects the lightest finger contact, and an indicator lights up to confirm when they are activated. Because they don't require you to press down a button to operate, they meet ANSI B11.TR1 standards to reduce hand, wrist, and arm fatigue. You'll need a relay or controller to complete your system—upgrade to a controller if you plan to operate additional devices beyond your switch.
Safety controller expansion modules can be added to safety controllers to increase the number of inputs.
Telescoping stands can be added to switches with finger-touch actuators to mount them away from a wall. The stands telescope to adjust the height of the switch and tilt to adjust the angle of the switch.

Actuator | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Material | Color | Switching Current @ Voltage | Ht. | Wd. | Dp. | No. of Holes | Hole Dia. | Mounting Fasteners Included | Features | Each | |
Finger-Touch Actuators | |||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | DPST-1NO/1NC | Plastic | Black | 0.15 A @ 24 V DC | 3 7/16" | 18 11/16" | 5 1/2" | 4 | 5/16" | No | Emergency Stop Button, Output Indicator, Power Indicator | 00000000 | 0000000 |

hp @ Switching Voltage | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | No. of Terminals | Switching Current @ Voltage | Max. Switching Voltage | Single Phase | Three Phase | Auxiliary Contact Switch Starting Position (No. of Contacts) | For DIN Rail Size, mm | Wire Connection Type | Features | Max. System Safety Rating | Auxiliary Contact Switch Starting Position | Each | |
3 3 Off (Normally Open)—3PST-NO | |||||||||||||
24V DC | 18 | 9 A @ 400 V AC | 600V AC | 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 1 Off (Normally Open) (2) 1 On (Normally Closed) (3) | 35 | Screw Terminals | Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry | PLe, SIL3, CAT 4, 600V | 2 Off (Normally Open) and 3 On (Normally Closed) | 0000000 | 0000000 |



USB Connection | Ethernet Connection | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Inputs | Input Voltage | Signal Output Type | Type | Standard | Gender | Type | Gender | Communication Protocol | For Max. No. of Expansion Modules | Ht. | Wd. | Dp. | Display Type | Each | |
USB Connection | |||||||||||||||
26 | 24V DC | PNP | Micro B | 2.0 | Female | __ | __ | __ | 8 | 4 5/16" | 1 3/4" | 5 1/16" | LCD | 00000000 | 000000000 |
USB and Ethernet Connection | |||||||||||||||
26 | 24V DC | PNP | Micro B | 2.0 | Female | RJ45 | Female | Ethernet/IP, Modbus TCP, Profinet | 8 | 4 5/16" | 1 3/4" | 5 1/16" | __ | 00000000 | 00000000 |

Input Voltage | No. of Outputs | Signal Output Type | Ht. | Wd. | Dp. | Each | |
24V DC | 4 | PNP | 4 5/16" | 1" | 5 1/16" | 00000000 | 0000000 |


Base Mounting Holes | Head Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Head Movement | Tilt Range of Motion | Material | No. of | Dia. | No. of | Dia. | Mounting Fasteners Included | Each | |
31 1/2"-48 1/2" | 24 1/16" | 24" | Tilt | 30° | Steel | 4 | 29/64" | 2 | 5/16" | Yes | 00000000 | 0000000 |

Mounting | ||||||||
---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Material | No. of Holes | Hole Dia. | Mounting Fasteners Included | Each | |
5 15/16" | 10 1/4" | 3/8" | Steel | 4 | 3/8" | Yes | 00000000 | 000000 |

Wire Leads | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | Signal Output Type | Ht. | Wd. | Dp. | Thread Size | Cable Lg., ft. | No. of | Lg., ft. | Features | Each | |
10V DC-30V DC | PNP | 2 5/16" | 2 3/8" | 1 11/16" | M30 × 1.5 mm | 1 | 5 | 1 | Output Indicator, Power Indicator | 00000000 | 0000000 |
Ultrasonic Noncontact Level Switches for Chemicals

Use high-frequency sound waves to detect chemical level. This switch has three relays that can be programmed for multiple set points. Use it to activate several alarms or to automate tank filling and emptying. It’s rated NEMA 4X for protection from corrosion and washdowns.
Pipe | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Sensing Distance, ft. | Max. Pressure | Temp. Range, °F | Switch Starting Position | Industry Designation | Current | Lg. | Wd. | Electrical Connection | Environmental Rating | Trade Size | Thread Type | Gender | Each | |
95V AC/250V AC Input Voltage | |||||||||||||||||
Polycarbonate Plastic Body | |||||||||||||||||
1 | NPT | Male | 0.33-9.8 | 30 psi @ 70° F | -5° to 140° | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.17 A @ 120 V AC | 3 15/16" | 5 3/16" | Screw Terminals | IP65, NEMA 4X | 1/2 | NPT | Female | 0000000 | 0000000 |