Choosing a Proximity Switch
More
Choosing an Electrical Switch
More
No-Distance-Correction DC Metallic-Object Proximity Switches




Micro
M12 Plug
Nano
M8 Plug
Eliminate the need to calculate the sensing distance when using different metals—these switches sense all metal at the same distance. Also known as inductive proximity switches, they remotely sense metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. They’re often used with programmable logic controllers (PLCs). All meet American, Canadian, and European safety standards. They’re also rated IP66, IP68, and IP69K for protection against dust, temporary submersion, and high-pressure, high-temperature washdowns. Also known as K=1 sensors.
To view switch wiring diagrams, select a part number and click Product Detail.
Flush switches, also known as embeddable or shielded switches, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting switches at close range and can be mounted close together without causing interference. Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches.
Stainless steel switches resist corrosion better than brass switches. They’re best for harsh environments.
Switches with a plug connect to cables with a socket (sold separately), so you can quickly connect and disconnect the switch.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
Switches | Cables with Sockets | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Circuit Protection | Cable Lead Lg., ft. | Temperature Range, °F | Environmental Rating | Each | Each | ||
Brass Housing with Plastic Face | |||||||||||||||
Flush with 3-Pole Micro M12 Plug and LED Status Indicators | |||||||||||||||
| 1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 00000000 | 000000 | 0000000 | 000000 |
Projecting with 3-Pole Micro M12 Plug and LED Status Indicators | |||||||||||||||
| 1 Off (Normally Open) | 12 | 10 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 00000000 | 00000 | 0000000 | 00000 |
Stainless Steel Housing with Plastic Face | |||||||||||||||
Flush with 3-Pole Micro M12 Plug and LED Status Indicators | |||||||||||||||
| 1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 18 | 8 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 18 | 8 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 30 | 15 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 000000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 30 | 15 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 000000 | 0000000 | 00000 |
Flush with 3-Pole Nano M8 Plug and LED Status Indicators | |||||||||||||||
| 1 Off (Normally Open) | 8 | 3 | PNP | 10V DC-30V DC | 100mA | __ | 40 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 00000000 | 00000 | 0000000 | 00000 |
Flush with Wire Leads and LED Status Indicator | |||||||||||||||
| 1 Off (Normally Open) | 8 | 3 | PNP | 10V DC-30V DC | 100mA | 3 | 38 | Overload Short Circuit | 6 1/2 | -40° to 185° | IP66, IP68, IP69K | 00000000 | 00000 | 000000 | 00 |
Projecting with 3-Pole Micro M12 Plug and LED Status Indicators | |||||||||||||||
| 1 Off (Normally Open) | 12 | 8 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 12 | 8 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 12 | 10 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 12 | 10 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 18 | 12 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 18 | 12 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 18 | 15 | PNP | 10V DC-30V DC | 100mA | __ | 45 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 18 | 15 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 00000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 30 | 22 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 000000 | 0000000 | 00000 |
| 1 Off (Normally Open) | 30 | 30 | PNP | 10V DC-30V DC | 100mA | __ | 60 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 0000000 | 000000 | 0000000 | 00000 |
Projecting with 3-Pole Nano M8 Plug and LED Status Indicators | |||||||||||||||
| 1 Off (Normally Open) | 8 | 6 | PNP | 10V DC-30V DC | 100mA | __ | 40 | Overload Short Circuit | __ | -40° to 185° | IP66, IP68, IP69K | 00000000 | 00000 | 0000000 | 00000 |
Projecting with Wire Leads and LED Status Indicator | |||||||||||||||
| 1 Off (Normally Open) | 8 | 6 | PNP | 10V DC-30V DC | 100mA | 3 | 38 | Overload Short Circuit | 6 1/2 | -40° to 185° | IP66, IP68, IP69K | 00000000 | 00000 | 000000 | 00 |
Hazardous Location DC Metallic-Object Proximity Switches
Use these switches to sense objects in volatile areas. Intrinsically safe, they produce a NAMUR signal, which operates at a low current and voltage, so they won’t ignite or create sparks in hazardous locations. They are ATEX and IECEx internationally certified to protect against explosion in environments containing flammable gases and combustible dust. Switches must be connected to the required barriers (sold separately), which reduce the current and voltage coming from your power source. Unlike the switches, however, the barriers must be located in a separate nonhazardous area.
Also known as inductive proximity switches, these switches detect metallic objects—even if they’re obscured by water, oil, dirt, or a surface finish. Send their signal to programmable logic controllers (PLCs) to support automated processes. Switches meet various domestic and international safety standards.
To view switch wiring diagrams, select a part number and click Product Detail.
Flush switches, also known as embeddable or shielded switches, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting switches at close range and can be mounted close together without causing interference. Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches.
Switches with a 4-pole Micro M12 plug connect to NAMUR cables with a connector (sold separately), allowing you to quickly connect and disconnect the switch.
All switches seal out dust. IP66 rated switches protect against high-volume washdowns. Switches rated IP67 can be submerged for up to 30 minutes.



Micro
M12 Plug
| Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Circuit Protection | Cable Lead Lg., ft. | Temperature Range, °F | Environmental Rating | Each | |
Stainless Steel Housing with Plastic Face | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flush with Wire Leads | |||||||||||||
| 1 On (Normally Closed) | 6.5 | 1.5 | NAMUR | 8V DC-8.5V DC | 10mA | 2 | 22 | __ | 6 1/2 | -10° to 210° | IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA IP66 IP67 | 0000000 | 0000000 |
| 1 On (Normally Closed) | 8 | 1.5 | NAMUR | 8V DC-8.5V DC | 10mA | 2 | 22 | __ | 6 1/2 | -10° to 210° | IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA IP66 IP67 | 0000000 | 000000 |
Flush with 4-Pole Micro M12 Plug | |||||||||||||
| 1 On (Normally Closed) | 12 | 4 | NAMUR | 8V DC-8.5V DC | 10mA | __ | 55 | Reverse Polarity Short Circuit | __ | -10° to 210° | IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA IP66 IP67 | 0000000 | 000000 |
| 1 On (Normally Closed) | 18 | 8 | NAMUR | 8V DC-8.5V DC | 10mA | __ | 55 | Reverse Polarity Short Circuit | __ | -10° to 210° | IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA IP66 IP67 | 0000000 | 000000 |
Projecting with 4-Pole Micro M12 Plug | |||||||||||||
| 1 On (Normally Closed) | 30 | 15 | NAMUR | 8V DC-8.5V DC | 10mA | __ | 55 | Reverse Polarity Short Circuit | __ | -10° to 210° | IEC Zone 0 Groups IIC, IIB, IIA IEC Zone 20 Groups IIIC, IIIB, IIIA IP66 IP67 | 0000000 | 000000 |


Inputs | Outputs | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Operating Voltage | Voltage | Current | No. of | Signal Type | Current | No. of | Signal Type | Switching Frequency | Environmental Rating | Each | |
Plastic Housing | |||||||||||
| 115V AC | 10V DC | 8mA | 1 | NAMUR | 2 A @ 253 V AC 2 A @ 40 V DC 4 A @ 126 V AC | 1 | Relay | 10 Hz | Associated Apparatus for IEC Zone 0 Groups IIC, IIB, IIA Associated Apparatus for IEC Zone 20 Groups IIIC, IIIB, IIIA IP20 | 0000000 | 0000000 |
| 24V DC | 10V DC | 8mA | 1 | NAMUR | 0.05 A @ 24 V DC | 2 | Transistor | 5 kHz | Associated Apparatus for IEC Zone 0 Groups IIC, IIB, IIA Associated Apparatus for IEC Zone 20 Groups IIIC, IIIB, IIIA IP20 | 0000000 | 000000 |
Hazardous Location Rotatable DC Metallic-Object Proximity Switches
Twist the sensor to detect metallic objects where explosive dust or gas may be present—the sensor rotates for front, side, top, or bottom sensing. These switches are UL and C-UL listed as well as ATEX and IECEx certified for hazardous locations. Their NAMUR signal produces low current and low voltage, so they won’t spark or ignite. You must connect them to a barrier (sold separately), which reduces the current and voltage that enters your hazardous area. Install the barrier in a separate location that doesn’t contain explosive gas or dust.
Because you can rotate their sensor, these switches make good replacements for limit switches with actuators that could break when hit. They’re often known as inductive proximity switches and detect objects even if they’re covered by water, oil, dirt, or a surface finish. Sensing distance is based on the type of material that’s sensed; the distance listed is for mild steel. Send signals from these switches to programmable logic controllers (PLCs) to support automated processes.
These switches have a 4-pole micro M12 plug that connects to cables with a socket (sold separately), so you can quickly connect and disconnect them. You can also check on them from any angle, thanks to LED status indicators on their corners. All are CE marked for safety.
To view switch wiring diagrams, select a part number and click Product Detail.
Flush switches, also called embeddable and shielded switches, are more accurate than projecting switches at close range. They also won’t interfere with each other’s signals when installed close together. Their sensor face mounts evenly with any material, including metal.
IP rated, all switches seal out dust and water from high-pressure washdowns.

Micro
M12 Plug
| Switch Starting Position | Lg., mm | Wd., mm | Ht., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | Circuit Protection | Temp. Range, °F | Environmental Rating | Each | |
Plastic Housing | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flush with 4-Pole Micro M12 Plug | ||||||||||||
| 1 On (Normally Closed) | 67 | 40 | 40 | 20 | NAMUR | 8V DC-8.5V DC | 10mA | Reverse Polarity Short Circuit | -10° to 210° | IEC Zone 0 Groups IIC, IIB, IIA NEC Class III Divisions 1, 2 IEC Zone 20 Groups IIIC, IIIB, IIIA NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G IP66 IP69K | 0000000 | 0000000 |

Inputs | Outputs | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Operating Voltage | Voltage | Current | No. of | Signal Type | Current | No. of | Signal Type | Switching Frequency | Environmental Rating | Each | |
Plastic Housing | |||||||||||
| 115V AC | 10V DC | 8mA | 1 | NAMUR | 2 A @ 253 V AC 2 A @ 40 V DC 4 A @ 126 V AC | 1 | Relay | 10 Hz | Associated Apparatus for IEC Zone 0 Groups IIC, IIB, IIA Associated Apparatus for IEC Zone 20 Groups IIIC, IIIB, IIIA IP20 | 0000000 | 0000000 |
| 24V DC | 10V DC | 8mA | 1 | NAMUR | 0.05 A @ 24 V DC | 2 | Transistor | 5 kHz | Associated Apparatus for IEC Zone 0 Groups IIC, IIB, IIA Associated Apparatus for IEC Zone 20 Groups IIIC, IIIB, IIIA IP20 | 0000000 | 000000 |
Photoelectric Switches with Relay Output

A built-in relay produces AC voltage output. These switches are often used with older programmable logic controllers (PLCs). They detect the presence or absence of an object moving at high speeds with a light beam.
Direct sensing switches detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
Receiver switches detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing and reflector switches.
Reflector switches detect an object when it passes between the switch and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing switches.
IP66 rated switches protect against washdowns.
Reflector | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Light Beam Switch Operation | Max. Sensing Distance | Industry Designation | Switching Current @ Voltage | Input Voltage | Lg. | Wd. | Ht. | Housing Material | Ht. | Wd. | Temperature Range, °F | Environmental Rating | Each | |
With Screw Terminals | ||||||||||||||
Direct Sensing Switches with Infrared Light Beam | ||||||||||||||
| On When Object Absent/On When Object Present | 39" | SPST | 3 A @ 250 V AC/30 V DC | 24V AC-240V AC/24V DC-240V DC | 2 3/4" | 1" | 2 11/16" | Plastic | __ | __ | -10° to 130° | IP66 | 0000000 | 0000000 |
Receiver Switches with Visible Light Beam | ||||||||||||||
| On When Object Absent/On When Object Present | 65.5ft. | SPST | 3 A @ 250 V AC/30 V DC | 24V AC-240V AC/24V DC-240V DC | 2 3/4" | 1" | 2 11/16" | Plastic | __ | __ | -10° to 130° | IP66 | 0000000 | 000000 |
Reflector Switches with Visible Light Beam | ||||||||||||||
| On When Object Absent/On When Object Present | 23ft. | SPST | 3 A @ 250 V AC/30 V DC | 24V AC-240V AC/24V DC-240V DC | 2 3/4" | 1" | 2 11/16" | Plastic | 2 3/8" | 1 5/8" | -10° to 130° | IP66 | 0000000 | 000000 |
| Replacement Reflector | 0000000 | Each | 000000 |
Time-Delay Photoelectric Switches with Relay Output

Set these switches to delay activation by up to five seconds after detecting an object. A built-in relay produces AC voltage output. They’re often used with older programmable logic controllers (PLCs). They detect the presence or absence of an object moving at high speeds with a light beam. All are rated IP66 for protection against washdowns.
Direct sensing switches detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
Receiver switches detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing and reflector switches.
Reflector switches detect an object when it passes between the switch and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing switches.
Reflector | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Light Beam Switch Operation | Max. Sensing Distance | Industry Designation | Switching Current @ Voltage | Input Voltage | Timer Relay Function | Lg. | Wd. | Ht. | Housing Material | Ht. | Wd. | Temperature Range, °F | Each | |
With Screw Terminals | ||||||||||||||
Direct Sensing Switch with Infrared Light Beam | ||||||||||||||
| On When Object Absent, On When Object Present | 39" | SPST | 3 A @ 250 V AC/30 V DC | 24V AC-240V AC/24V DC-240V DC | Delayed Off Delayed Start (Delay-on-Make) Switch-On (Single-Shot) | 2 3/4" | 1" | 2 11/16" | Plastic | __ | __ | -10° to 130° | 0000000 | 0000000 |
Receiver Switch with Visible Light Beam | ||||||||||||||
| On When Object Absent, On When Object Present | 65.5ft. | SPST | 3 A @ 250 V AC/30 V DC | 24V AC-240V AC/24V DC-240V DC | Delayed Off Delayed Start (Delay-on-Make) Switch-On (Single-Shot) | 2 3/4" | 1" | 2 11/16" | Plastic | __ | __ | -10° to 130° | 0000000 | 000000 |
Reflector Switch with Visible Light Beam | ||||||||||||||
| On When Object Absent, On When Object Present | 23ft. | SPST | 3 A @ 250 V AC/30 V DC | 24V AC-240V AC/24V DC-240V DC | Delayed Off Delayed Start (Delay-on-Make) Switch-On (Single-Shot) | 2 3/4" | 1" | 2 11/16" | Plastic | 2 3/8" | 1 5/8" | -10° to 130° | 0000000 | 000000 |
| Replacement Reflector | 0000000 | Each | 000000 |
Washdown Wall-Mount Motion- and Light-Sensing Light Controls

Rated NEMA 4X and IP66 for use in washdown environments, these controls have an actuator that’s sealed to keep water out. An infrared sensor uses body heat to sense movement. They turn lights on when they detect motion and off when a room is empty or there’s enough daylight. To work properly, they need an unobstructed view of your space.
Power controllers (sold separately) are required to switch a 120- or 277-volt AC lighting circuit. They have a relay that switches a maximum 20 amp load.
Conduit | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Max. Mounting Ht., ft. | Pivot Angle | Color | Housing Material | Ht. | Wd. | Dp. | Wire Lead Lg. | Connection Gender | Trade Size | Thread Type | Environmental Rating | Specifications Met | Each | |
| 1,600 | 1 | 24V DC | 12 | 135° | Gray | Plastic | 6" | 3 1/2" | 1 11/16" | 8" | Male | 1/2 | NPT | NEMA 4X, IP66 | UL Listed, C-UL Listed | 0000000 | 0000000 |
| Power Controller | 0000000 | Each | 0000000 |
Light Beam Finger-Touch Switches

An infrared light beam senses the lightest finger contact to switch a circuit on or off. The included guard prevents accidental activation. An indicator lights up to confirm that switches are actuated. They’re rated NEMA 4X, 13, and IP66 for protection from corrosion, washdowns, and oil/coolant spraying.
Switches with a 5-pole mini plug can quickly be changed out.
Wire Leads | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Actuator Color | Switching Current @ Voltage | Current Output, mA | Input Voltage | Dp. Behind Panel | No. of | Ga. | Features | Each | |
Plastic Actuator with Wire Leads | |||||||||||||
For 30 mm Panel Cutout Dia. | |||||||||||||
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 120V AC | 3/4" | 5 | 22 | Guard Output Indicator Power Indicator | 00000000 | 0000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 20V AC-30V AC/20V DC-30V DC | 3/4" | 5 | 22 | Guard Output Indicator Power Indicator | 00000000 | 000000 |
Plastic Actuator with Wire Leads and NPN Output | |||||||||||||
For 30 mm Panel Cutout Dia. | |||||||||||||
| __ | __ | Springs Back (Momentary) | __ | Black | __ | 150 | 10V DC-30V DC | 3/4" | 4 | 22 | Guard Output Indicator Power Indicator | 00000000 | 000000 |
Plastic Actuator with 5-Pole Mini Plug | |||||||||||||
For 30 mm Panel Cutout Dia. | |||||||||||||
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 120V AC | 1 3/8" | __ | __ | Guard Output Indicator Power Indicator | 00000000 | 000000 |
| 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 20V AC-30V AC/20V DC-30V DC | 1 3/8" | __ | __ | Guard Output Indicator Power Indicator | 00000000 | 000000 |
Finger-Touch Switches

The light touch of a finger turns circuits on and off without pressing down a contact. Program these switches to fit your application—control their color, pattern, and sensitivity. Change the color to show different process statuses. For more visibility, change the intensity of the color or choose a light pattern. These switches can flash, rotate, and show other patterns, all at speeds you can control. To change how much force they need to actuate, alter the sensitivity. With a high sensitivity, they’ll actuate even if you’re wearing gloves. With a low sensitivity, they’re more resistant to accidental actuation.
To program your switch, download the free Banner Pro Editor Software. You’ll need a switch programming kit (sold separately) to connect your switch to the software.
Switches with a copolyester base are FDA compliant for incidental food contact once installed.
| Dia. | Ht. | Switch Starting Position | Switch Action | Message (Actuator Color) | Signal Type | Configurable Light Settings | Current Output, mA | Input Voltage Range | Dp. Behind Panel | Environmental Rating | Each | ||
Polycarbonate Plastic Base with 8-Pole Micro M12 Plug and PNP/NPN Output | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For 22 mm Panel Cutout Dia. | |||||||||||||
| A | 7/8" | 5/32" | 1 Off (Normally Open) | Springs Back (Momentary) | Touch Activation Symbol (Amber, Blue, Cyan, Green, Lime Green, Magenta, Orange, Red, Rose, Sky Blue, Spring Green, Violet, White, Yellow) | Light | Color, Intensity, Pattern, Speed | 150 | 10V DC-30V DC | 1.72" | IP66, IP67, IP69K | 00000000 | 0000000 |
| A | 7/8" | 5/32" | 1 Off (Normally Open) | Stays Switched (Maintained) | Touch Activation Symbol (Amber, Blue, Cyan, Green, Lime Green, Magenta, Orange, Red, Rose, Sky Blue, Spring Green, Violet, White, Yellow) | Light | Color, Intensity, Pattern, Speed | 150 | 10V DC-30V DC | 1.72" | IP66, IP67, IP69K | 00000000 | 000000 |
Copolyester Plastic Base with 8-Pole Micro M12 Plug and PNP/NPN Output | |||||||||||||
For 22 mm Panel Cutout Dia. | |||||||||||||
| A | 7/8" | 5/32" | 1 Off (Normally Open) | Springs Back (Momentary) | Touch Activation Symbol (Amber, Blue, Cyan, Green, Lime Green, Magenta, Orange, Red, Rose, Sky Blue, Spring Green, Violet, White, Yellow) | Light | Color, Intensity, Pattern, Speed | 150 | 10V DC-30V DC | 1.72" | IP66, IP67, IP69K | 00000000 | 000000 |
| A | 7/8" | 5/32" | 1 Off (Normally Open) | Stays Switched (Maintained) | Touch Activation Symbol (Amber, Blue, Cyan, Green, Lime Green, Magenta, Orange, Red, Rose, Sky Blue, Spring Green, Violet, White, Yellow) | Light | Color, Intensity, Pattern, Speed | 150 | 10V DC-30V DC | 1.72" | IP66, IP67, IP69K | 00000000 | 000000 |

USB | |||||||
|---|---|---|---|---|---|---|---|
| Input Voltage | Connection Type | Standard | Power Plug Type | Operating System Compatibility | Includes | Each | |
| 24V DC | A | 2.0 | Two Prong | Windows 7 or Later | Micro M12 Cords, Power Supply, Splitter, Wire Splicing Connectors | 00000000 | 0000000 |
Noncontact Level Switches for Conductive Liquids
Measure the level of conductive liquids without drilling a hole in your tank—these switches mount to the outside of the tank and track the capacitance between them and the tank’s contents. Use them on nonconductive plastic or glass wall tanks; they’re not compatible with metal tanks. They automatically adapt to your tank’s wall thickness, making them ready to use. These switches only respond when the liquid reaches the desired level, so foam and residue on the top of the liquid won’t trigger them early. For even more challenging setups, such as those with thick, sticky fluids, or if your tank has walls as thick as 10 mm, you can teach these switches to avoid false detections. All have LED indicators to show their power and output status.
Made of plastic, their body is chemical resistant and NEMA and IP rated, so it keeps out dust and dirt, as well as drips of oil and jets of hot water. UL listed, C-UL listed, and CE marked, they meet U.S., Canadian, and European Union safety standards.
Mount these switches directly on your sight glass using their adhesive back or use the included mounting bracket if you’ll need to remove them frequently. They also include foam pads for mounting them using straps around the outside of your tank.
PNP switches communicate with your system by sending a positive signal. NPN switches send a negative signal to communicate with your system.
Switches with an M8 4-pin connection have a standard plug that’s easy to connect. Switches with wire leads need to be hardwired, so use them in applications where you won’t move them often.

| Signal Output Type | Width | Height | Thickness | Temperature Range, °F | Switch Starting Position | Industry Designation | Current | Environmental Rating | Each | |
10V DC/30V DC Input Voltage | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
Polycarbonate/PBT Plastic Blend Body | ||||||||||
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 Off (Normally Open) | SPST-NO | 0.1 A @ 30 V DC | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 0000000 |
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 On (Normally Closed) | SPST-NC | 0.1 A @ 30 V DC | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |

| Signal Output Type | Width | Height | Thickness | Temperature Range, °F | Switch Starting Position | Industry Designation | Current | Wire Lead Length, ft. | Environmental Rating | Each | |
10V DC/30V DC Input Voltage | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Polycarbonate/PBT Plastic Blend Body | |||||||||||
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 Off (Normally Open) | SPST-NO | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 0000000 |
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 On (Normally Closed) | SPST-NC | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |
| NPN | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 Off (Normally Open) | SPST-NO | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |
| NPN | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 On (Normally Closed) | SPST-NC | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |