Choosing a Proximity Switch
More
Choosing an Electrical Switch
More
Harsh Environment DC Universal-Object Proximity Switches

Micro
M12 Plug
Rated NEMA 6P, 12, IP68 and IP69K, these switches protect against corrosion and high-pressure, high-temperature washdowns. Also known as capacitive proximity switches, they remotely sense both metallic and nonmetallic objects but their strength is in sensing materials such as plastic, ceramic, and clear targets. They’re often used with programmable logic controllers (PLCs) and produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included). They mount flush with the surface of any material, including metal, and are also known as embeddable or shielded switches. The 4-pole Micro M12 plug connects to cables with sockets (sold separately), allowing you to quickly connect and disconnect the switch.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
| Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | Lg., mm | Circuit Protection | Temperature Range, °F | Environmental Rating | Each | |
Plastic Housing with Plastic Face | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
With 4-Pole Micro M12 Plug | |||||||||||
| 1 Off (Normally Open) and 1 On (Normally Closed) | 30 | 16 | PNP | 10V DC-40V DC | 200mA | 61 | Reverse Polarity Short Circuit | -20° to 185° | NEMA 6P, NEMA 12, IP68, IP69K | 0000000 | 0000000 |
| 1 Off (Normally Open) and 1 On (Normally Closed) | 30 | 16 | NPN | 10V DC-40V DC | 200mA | 61 | Reverse Polarity Short Circuit | -20° to 185° | NEMA 6P, NEMA 12, IP68, IP69K | 0000000 | 000000 |
| Cable with Socket | 0000000 | Each | 000000 |
Fingerprint Switches


Use fingerprints to confirm the identity of personnel before granting access to secure areas or equipment. Switches light up green to indicate that they have accepted the fingerprint and are sending an output signal. The front faces of the switches meet NEMA 12 and IP65. The rear faces of the switches meet IP20.
Covers (sold separately) have an adhesive-back hinge, so you can stick them on to your switch. Keep the cover flipped down to protect the switch’s sensor from dust and debris.
Switches | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Leads | Covers | |||||||||||||
| No. of Users | No. of Fingerprints per User | Switch Action | Actuator Color | Signal Output Type | Current Output, mA | Input Voltage | Bulb Voltage | Dp. Behind Panel | No. of | Ga. | Each | Each | ||
Plastic Actuator with Wire Leads | ||||||||||||||
For 22 mm Panel Cutout Dia. | ||||||||||||||
| 200 | 2 | Springs Back (Momentary) | Black | PNP | 200 | 20V DC-30V DC | 3.3V DC | 1 9/16" | 3 | 22 | 0000000 | 0000000 | 00000000 | 000000 |
Plastic Actuator with 3-Pole Micro M12 Plug | ||||||||||||||
For 22 mm Panel Cutout Dia. | ||||||||||||||
| 200 | 2 | Springs Back (Momentary) | Black | PNP | 200 | 20V DC-30V DC | 3.3V DC | 1 9/16" | __ | __ | 0000000 | 000000 | 00000000 | 00000 |
Noncontact Level Switches for Conductive Liquids
Measure the level of conductive liquids without drilling a hole in your tank—these switches mount to the outside of the tank and track the capacitance between them and the tank’s contents. Use them on nonconductive plastic or glass wall tanks; they’re not compatible with metal tanks. They automatically adapt to your tank’s wall thickness, making them ready to use. These switches only respond when the liquid reaches the desired level, so foam and residue on the top of the liquid won’t trigger them early. For even more challenging setups, such as those with thick, sticky fluids, or if your tank has walls as thick as 10 mm, you can teach these switches to avoid false detections. All have LED indicators to show their power and output status.
Made of plastic, their body is chemical resistant and NEMA and IP rated, so it keeps out dust and dirt, as well as drips of oil and jets of hot water. UL listed, C-UL listed, and CE marked, they meet U.S., Canadian, and European Union safety standards.
Mount these switches directly on your sight glass using their adhesive back or use the included mounting bracket if you’ll need to remove them frequently. They also include foam pads for mounting them using straps around the outside of your tank.
PNP switches communicate with your system by sending a positive signal. NPN switches send a negative signal to communicate with your system.
Switches with an M8 4-pin connection have a standard plug that’s easy to connect. Switches with wire leads need to be hardwired, so use them in applications where you won’t move them often.

| Signal Output Type | Width | Height | Thickness | Temperature Range, °F | Switch Starting Position | Industry Designation | Current | Environmental Rating | Each | |
10V DC/30V DC Input Voltage | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
Polycarbonate/PBT Plastic Blend Body | ||||||||||
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 Off (Normally Open) | SPST-NO | 0.1 A @ 30 V DC | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 0000000 |
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 On (Normally Closed) | SPST-NC | 0.1 A @ 30 V DC | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |

| Signal Output Type | Width | Height | Thickness | Temperature Range, °F | Switch Starting Position | Industry Designation | Current | Wire Lead Length, ft. | Environmental Rating | Each | |
10V DC/30V DC Input Voltage | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Polycarbonate/PBT Plastic Blend Body | |||||||||||
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 Off (Normally Open) | SPST-NO | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 0000000 |
| PNP | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 On (Normally Closed) | SPST-NC | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |
| NPN | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 Off (Normally Open) | SPST-NO | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |
| NPN | 5/8" | 1 5/16" | 5/16" | -10° to 175° | 1 On (Normally Closed) | SPST-NC | 0.1 A @ 30 V DC | 6 | NEMA 4X, NEMA 12, IP68, IP69K, IP66 | 0000000 | 000000 |