Choosing a Proximity Switch
More
DC Metallic-Object Proximity Switches

Also known as inductive proximity switches, these detect metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the target material. The distance listed is for mild steel. They’re often used with programmable logic controllers (PLCs) and produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included).
Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches with the same diameter.
Switches with IO link can be configured remotely when connected to a PLC, a human-machine interface (HMI), or a computer.
IP67 and IP68 rated switches are protected from temporary submersion. NEMA 6P rated switches are protected from corrosion and washdowns.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
For technical drawings and 3-D models, click on a part number.
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Circuit Protection | Cable Lead Lg., ft. | Temperature Range, °F | Each | |
Stainless Steel Housing with Plastic Face (IP67 and NEMA 6P) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Projecting with Wire Leads and IO Link | ||||||||||||
1 On (Normally Closed) | 8 | 2.5 | PNP | 10V DC-30V DC | 200mA | 3 | 35 | Overload Reverse Polarity Short Circuit | 6 1/2 | -10° to 155° | 00000000 | 000000 |