About Safety Ratings for Electrical Testing
More
Voltage Detectors
Confirm that voltage is present in receptacles, cables, and other electrical components. The detectors have light or sound alerts to indicate voltage.
Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/705/7053k51-@halfx_636952299465838611.png?ver=imagenotfound)
Batteries | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Connection Type | Manufacturer Model Number | Safety Rating | AC Voltage | Measures | Alert Type | Required | Included | Specifications Met | Each | |
Long-Reach Tip | 1AC-II | CAT IV, 1,000V | 90-1,000 | AC Voltage | Light, Sound | Yes | Yes | CSA Certified, CSA-US Certified | 0000000 | 000000 |
Long-Reach Tip | 1LAC-II | CAT IV, 1,000V | 20-90 | AC Voltage | Light, Sound | Yes | Yes | CSA Certified, CSA-US Certified | 0000000 | 00000 |
Fluke Vibrating Voltage Testers
![](/prerenderstable/mvPRE/contents/gfx/imagecache/705/7053k16p1-d01e-digital@halfx_636952298367832612.png?ver=imagenotfound)
Detect voltage with three types of alerts for extra safety—light, sound, and vibration. There are LEDs that light up to show the approximate voltage level, and a digital LCD shows precise voltage measurements. Fluke testers are known for quality and durability.
Manufacturer Model Number | Measures | Measurement Increments | Max. Resistance, kilohms | Alert Type | Display Type | Display Features | Includes | Lead Lg. | Safety Rating | Specifications Met | Batteries Included | Each | |
T+Pro | AC Voltage, Continuity, DC Voltage, Resistance | 12V, 24V, 48V, 120V, 208V, 240V, 277V, 480V, 600V | 10 | Light, Sound, Vibration | Digital, Light Indicator | Backlight | Test Leads | 34" | CAT IV, 600V | UL Listed, C-UL Listed | Yes | 0000000 | 0000000 |
Fluke Wireless Remote-Reading Voltage Meters
![](/prerenderstable/mvPRE/contents/gfx/imagecache/709/7093k421p1-d01e-digital@halfx_636918906273649102.png?ver=imagenotfound)
Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
Manufacturer Model Number | AC Calculation | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | Data Log Capacity | Display Count | Includes | Specifications Met | Batteries Included | Each | |
v3000 FC | True RMS | CAT IV, 600V | AC Voltage | 1,000 | __ | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | 00000000 | 0000000 |
v3001 FC | __ | CAT IV, 600V | DC Voltage | __ | 1,000 | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | 00000000 | 000000 |
Fluke Insulation Testing Multimeters
![](/prerenderstable/mvPRE/contents/gfx/imagecache/709/7093k68-@halfx_636975746762855558.png?ver=imagenotfound)
Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Environmental Rating | Each | |
Multimeters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||
1577 | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 0.2% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Test Leads | IP40 | 0000000 | 0000000 |
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 0000000 | 00000000 |
Multimeters with Calibration Certificate | |||||||||||||
True RMS AC Calculation | |||||||||||||
1577 | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 0.2% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Test Leads | IP40 | 00000000 | 00000000 |
1587 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 00000000 | 00000000 |
Fluke Test Sensors
Take temperature readings with a Fluke multimeter.
Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/709/7093k13p1-d01e-digital@halfx_636918889737687582.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/709/7093k51p1-d01e-digital@halfx_636918904035672877.png?ver=imagenotfound)
Manufacturer Model Number | For Fluke Model Number | Temperature Range, ° F | AC Voltage | DC Voltage | Test End | Connection End | Cord Lg. | Test End Insulation Material | Each | |
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40° to 500° | __ | __ | Needle Tip | Sheathed Banana Jack | 39" | PTFE | 0000000 | 000000 |
80TK | 27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789 | -40° to 500° | 24 | 60 | Needle Tip | Sheathed Banana Plug | 39" | PTFE | 0000000 | 000000 |
Fluke Test Lead Kits
![](/prerenderstable/mvPRE/contents/gfx/imagecache/709/7093k49p1-d01e-digital@halfx_636918890176376384.png?ver=imagenotfound)
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Manufacturer Model Number | For Fluke Model Number | AC Voltage | DC Voltage | Current, A | Safety Rating | Includes | Cord Lg. | Color | Each | |
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug, Two Needle Tips, Two Insulated Alligator Clips, Two Retractable Grabbers, Two Retractable Precision Grabbers, Two Retractable Precision Hooks, Pouch | 59" | Black, Red | 0000000 | 0000000 |
TLK289 | 287, 289, 376, 381 | 1,000 | 1,000 | 3 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug, Two Needle Tips, Two Insulated Alligator Clips, Two Retractable Grabbers, Two Retractable Precision Hooks, Thermocouple, Magnetic Hanger, Pouch | 59" | Black, Red | 0000000 | 000000 |
Current-Sensing Test Leads
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/757/7575k66-@halfx_636934324322602191.png?ver=imagenotfound)
Manufacturer Model Number | Test End | For Max. Cord Dia. | Connection End | AC Current, A | Current Accuracy | Current Output Signal Per Amp Supplied | For Current Range, A | AC Voltage | Safety Rating | Frequency Range | Jaw Opening | For Fluke Model Number | Cord Lg. | Batteries Required | Each | |
Measures AC Current | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
i400 | Current Clamp | 1.25" | Sheathed Banana Plug | 1-400 | 2% | 1.000 mA | 1-400 | 1,000 | CAT IV, 600V | 5 Hz-20 kHz | 1.25" | 27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 1587 | 59" | No | 0000000 | 0000000 |