Fixed-Setpoint Flow Switches for Drinking Water

Factory set to activate equipment when your drinking water system reaches a fixed level, these flow switches are easier to install than adjustable flow switches. They meet NSF/ANSI 61, so they're safe to use with drinking water. They actuate when your system’s flowing water pushes their paddle into a set position. These switches are single pole, single throw (SPST) and turn one device from off to on. IP rated, they seal out dust and can be lightly rinsed. They're accurate in any mounting orientation.
These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | Gender | Set Point, gpm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current @ Voltage | End-to-End Lg. | Environmental Rating | Specifications Met | Each | |
Noryl Plastic Body | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/2 | NPT | Female | 0.6 | 145 psi @ 70° F | -4° to 212° | 48V DC/ 230V AC | 1 A @ 48 V DC, 1 A @ 230 V AC | 2" | IP65 | CE Marked, NSF/ANSI 61 | 0000000 | 0000000 |
Fixed-Setpoint Flow Switches
Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting orientation.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
Choose a fitting material that is compatible with the liquid you intend to run through your line. Polypropylene and PPS plastic fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened. Bronze and 316 stainless steel fittings resist impact better than plastic fittings.
SPST (single pole, single throw) switches turn one device from off to on (normally open).
SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.

Stainless Steel Body
with Female Fittings
Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Trade Size | Thread Type | Gender | End-to-End Lg. | Mounting Orientation | Each | |
Bronze Body with Bronze Fittings | ||||||||||||||
SPDT | ||||||||||||||
1 | NPT | Female | 0.5 | 0.075 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 0000000 |
1 | NPT | Female | 1 | 0.15 | 300 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 3/8" | Any | 0000000 | 000000 |
1 | NPT | Female | 2 | 0.3 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 3 | 0.45 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 3/8" | Any | 0000000 | 000000 |
1 | NPT | Female | 4 | 0.6 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 6 | 0.9 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 8 | 1.2 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 1/4 | NPT | Female | 1 | 0.15 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4" | Any | 00000000 | 000000 |
1 1/4 | NPT | Female | 4 | 0.6 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4" | Any | 00000000 | 000000 |
1 1/4 | NPT | Female | 20 | 3 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4" | Any | 00000000 | 000000 |
1 1/2 | NPT | Female | 1.5 | 0.225 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4 1/2" | Any | 00000000 | 000000 |
1 1/2 | NPT | Female | 5 | 0.75 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4 1/2" | Any | 00000000 | 000000 |
1 1/2 | NPT | Female | 30 | 4.5 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4 1/2" | Any | 00000000 | 000000 |
2 | NPT | Female | 2 | 0.3 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 5 3/8" | Any | 00000000 | 000000 |
2 | NPT | Female | 5 | 0.75 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 5 3/8" | Any | 00000000 | 000000 |
2 | NPT | Female | 50 | 7.5 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 5 3/8" | Any | 00000000 | 000000 |
316 Stainless Steel Body with 316 Stainless Steel Fittings | ||||||||||||||
SPDT | ||||||||||||||
1 | NPT | Female | 0.5 | 0.075 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 2 | 0.3 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 4 | 0.6 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 6 | 0.9 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 | NPT | Female | 8 | 1.2 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 3 1/4" | Any | 00000000 | 000000 |
1 1/4 | NPT | Female | 1 | 0.15 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4 1/2" | Any | 00000000 | 00000000 |
1 1/4 | NPT | Female | 4 | 0.6 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 4 1/2" | Any | 00000000 | 00000000 |
2 | NPT | Female | 2 | 0.3 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 5 3/8" | Any | 00000000 | 00000000 |
2 | NPT | Female | 5 | 0.75 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 5 3/8" | Any | 00000000 | 00000000 |
2 | NPT | Female | 50 | 7.5 | 400 psi @ 70 ° F | -20° to 300° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | 1/2 | NPT | Male | 5 3/8" | Any | 00000000 | 00000000 |


Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Mounting Orientation | Each | ||
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
SPST | |||||||||||
A | 1/4 | NPT | Female | 0.042 | 0.006 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 000000 |
B | 3/4 | NPT | Female | 0.25 | 0.05 | 100 psi @ 70 ° F | 0° to 212° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 0000000 | 000000 |
B | 3/4 | NPT | Female | 1 | 0.2 | 100 psi @ 70 ° F | 0° to 212° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 0000000 | 000000 |
Flow Switches
Activate or deactivate equipment when your flow rate reaches a set point. These switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They’re accurate in any mounting orientation.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.

Conduit | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Set Point Range, gpm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current | Trade Size | Thread Type | Gender | End-to-End Lg. | Each | |
Bronze Body | |||||||||||
1 NPT Female | 1 to 6 | 400 psi @ 70° F | -20° to 200° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 3 1/4" | 0000000 | 0000000 |
1 NPT Female | 2 to 8 | 400 psi @ 70° F | -20° to 200° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 3 1/4" | 0000000 | 000000 |
1 NPT Female | 5 to 15 | 400 psi @ 70° F | -20° to 200° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 3 1/4" | 0000000 | 000000 |

Conduit | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Set Point Range, gpm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current | Trade Size | Thread Type | Gender | Port-to-Port Lg. | Each | |
Bronze Body | |||||||||||
3/4 NPT Female | 0.75 to 4 | 400 psi @ 70° F | -20° to 180° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 1 3/8" | 0000000 | 0000000 |
3/4 NPT Female | 2 to 8 | 400 psi @ 70° F | -20° to 180° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 1 3/8" | 0000000 | 000000 |
3/4 NPT Female | 7 to 14 | 400 psi @ 70° F | -20° to 180° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 1 3/8" | 0000000 | 000000 |
High-Pressure Flow Switches

Rated for pressures up to 3,600 psi, these switches measure the flow rate of liquids to activate or deactivate equipment when your flow rate reaches a set point. Tighten or loosen the adjustment screw on these switches to choose your flow rate anywhere within set point the range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, gpm | Approximate Difference Between Setpoint and Reset Point | Body Material | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Brass Body with 304 Stainless Steel Fittings | ||||||||||
1/4 NPT Female | 0.06 to 0.8 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 0000000 |
1/4 NPT Female | 0.25 to 2.6 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 0.3 to 6 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/2 NPT Female | 1 to 8 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/2 NPT Female | 2 to 10 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 000000 |
3/4 NPT Female | 8 to 34 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 000000 |
High-Pressure Flow Switches for Oil

Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting orientation.
These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, gpm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|
Brass Body with Brass Fittings | |||||||||
1/4 NPT Female | 0.03 to 0.12 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 0000000 |
1/4 NPT Female | 0.05 to 0.3 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 0.2 to 0.9 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 0.5 to 2.5 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
1/2 NPT Female | 1.5 to 5 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
3/4 NPT Female | 1 to 11 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
3/4 NPT Female | 2 to 18 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
1 NPT Female | 2 to 20 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 7 5/16" | IP65 | 0000000 | 000000 |
High-Pressure Flow Switches for Gases

Good for compressed-air systems and other compressed gases that reach up to 3,600 psi, these switches measure the flow rate to activate or deactivate equipment when they reach a set point. Tighten or loosen the adjustment screw to choose your flow rate anywhere within the set point range. As flowing gas pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
These switches are calibrated with and measure air accurately. They can also be used with other gases by applying your gases’ specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, scfm | Approximate Difference Between Setpoint and Reset Point | Body Material | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Brass Body with 304 Stainless Steel Fittings | ||||||||||
1/4 NPT Female | 0.4 to 4 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 0000000 |
1/4 NPT Female | 2 to 10 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 3 to 24 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/2 NPT Female | 4 to 30 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
3/4 NPT Female | 10 to 90 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 000000 |
3/4 NPT Female | 30 to 130 | Adjustable | Nickel Plated Brass | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 000000 |
Electronic Flow Switches

When these switches reach a set flow rate, they send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms. Use the adjustment screw to select their set point. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They must be mounted horizontally to function correctly. IP rated, they withstand dust, washdowns, and temporary submersion.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point Range, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | End-to-End Lg. | Environmental Rating | Specifications Met | Each | |
Aluminum/Brass/Plastic Body with Nickel-Plated Brass Fittings | |||||||||
---|---|---|---|---|---|---|---|---|---|
One Digital PNP Signal Output | |||||||||
3/4 NPT Female | 0.26 to 6.6 | 360 psi @ 70° F | 32° to 185° | 100 mA @ 30 V DC | 3" | IP65, IP67 | C-UL Listed, UL Listed, CE Marked | 0000000 | 0000000 |
1 NPT Female | 1.32 to 26.4 | 360 psi @ 70° F | 32° to 185° | 100 mA @ 30 V DC | 3 5/8" | IP65, IP67 | C-UL Listed, UL Listed, CE Marked | 0000000 | 000000 |