Smoke and Carbon Monoxide Detectors

When visible smoke particles or carbon monoxide is detected, this stand-alone detector alerts you with an audible alarm. It cannot be sold to Canada due to import regulations.
| Volume | Dia. | Dp. | Tandem Signaling Capable | Batteries Included | Specifications Met | Cannot Be Sold To | Each | |
| 85 dBA @ 10 ft. | 5 1/4" | 1 1/2" | No | Yes | UL 217, UL 2034 | Canada | 0000000 | 000000 |
Battery-Powered Smoke Detectors

Warn about the presence of smoke with these stand-alone detectors. They sound an audible alarm when invisible smoke particles are detected. They run on a nonreplaceable battery with a 10-year life. Detectors cannot be sold to Canada due to product labeling requirements.
| Volume | Dia. | Dp. | Tandem Signaling Capable | Batteries Included | Cannot Be Sold To | Each | |
| 85 dBA @ 10 ft. | 5" | 2" | No | Yes | Canada | 0000000 | 000000 |
Smoke Alarms with Strobe Light

When smoke is present, these alarms warn you with loud beeps and flashing lights. Use them alone or link several together so that if one detects smoke, they all go off in tandem. They install directly into your facility’s electrical system. These alarms also have a backup battery to keep them working during power outages. Due to import regulations, they cannot be sold to Canada.
Smoke Alarms | Smoke Detector Guards | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Volume | Electrical Connection | No. of Wire Leads | Voltage | Dia. | Dp. | Max. No. of Tandem Detectors | Batteries Included | Mounting Fasteners Included | Specifications Met | Cannot Be Sold To | Each | Each | ||
| 85 dBA @ 10 ft. | Wire Leads | 3 | 120V AC | 5 1/4" | 2 5/16" | 12 | Yes | Yes | California Fire Marshal Approved, ETL Listed, UL 1638, UL 217 | Canada | 0000000 | 0000000 | 0000000 | 000000 |
Remote Test Stations for Smoke Detectors for HVAC Systems

Check that your HVAC smoke detector is working properly. Wire these test stations to your smoke detector controller to test difficult to access smoke detectors from a convenient location. Indicator lights show if your smoke detector is powered on, if it senses smoke, and if its sensors are too dirty to detect smoke and need cleaning. These test stations activate with the turn of a key so you don’t turn them on by accident.
| Actuator Style | Switch Starting Position | No. of Terminals | Industry Designation | Voltage | Temp. Range, °F | Wire Connection Type | Wd. | Ht. | Mounting Hardware Included | Specifications Met | Each | |
| Key | 1 Off (Normally Open) | 5 | SPST-NO | 24V AC, 24V DC, 120V AC, 230V AC | 32° to 130° | Screw Terminals | 3" | 4 3/4" | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 000000 |
Smoke Detectors for HVAC Systems

Detect the presence of smoke in ducts and shut down HVAC units to avoid circulation. These sensors and controllers have standard RJ45 connections, so they work with most alarm systems and quickly snap in without needing to connect individual wires to terminals. UL and C-UL listed as well as FM and MEA approved, they meet strict safety standards. Choose from a sensor, controller, or sensor and controller unit.
Sensors measure rapid changes in air flow from smoke and fire but won’t register dust and debris, so they won’t cause a false alarm.
Controllers send signals from your sensor to a fire alarm control panel, which closes HVAC dampers when smoke is detected. Controllers can be installed up to 15 ft. away from your sensors and connected with cable. Connect up to two sensors per controller to monitor two sections of ductwork.
Sensor and controller units come with one controller and one sensor. Connect another sensor to cover another spot in your HVAC system.
Sensors require sampling tubes (sold separately) to bring in air from the duct. Mount the sampling tube inside the duct and connect it to the sensor on the outside of the duct by drilling a hole with the included template. For duct up to 36" wide, the sampling tube’s length should be 2/3 the width of the duct.
If your smoke detectors are hard to access, use remote test stations (sold separately) to check that they’re working properly from a convenient location.

| Lg. | Wd. | Dp. | Max. Number of Tandem Sensors | Wire Connection Type | Output Voltage | Input Voltage | Temp. Range, °F | Mounting Hardware Included | Specifications Met | Each | |
| 8 3/4" | 5 1/2" | 1 7/8" | 30 | Screw Terminals | 18V DC | 24V AC, 24V DC, 120V AC, 230V AC | 0° to 155° | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 0000000 |

| Lg. | Wd. | Dp. | For Max. Number of Sensors | Max. Number of Tandem Controllers | Wire Connection Type | Output Voltage | Input Voltage | Temp. Range, °F | Mounting Hardware Included | Specifications Met | Each | |
| 6 3/4" | 5 1/2" | 1 7/8" | 2 | 15 | Screw Terminals | 18V DC | 24V AC, 24V DC, 120V AC, 230V AC | 0° to 155° | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 0000000 |

| Lg. | Wd. | Dp. | Max. Number of Tandem Controllers | Max. Number of Tandem Sensors | Wire Connection Type | Output Voltage | Input Voltage | Temp. Range, °F | Mounting Hardware Included | Specifications Met | Each | |
| 14 1/2" | 5 1/2" | 1 7/8" | 15 | 30 | Screw Terminals | 18V DC | 24V AC, 24V DC, 120V AC, 230V AC | 0° to 155° | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 0000000 |

Check that your HVAC smoke detector is working properly. Wire these test stations to your smoke detector controller to test difficult to access smoke detectors from a convenient location. Indicator lights show if your smoke detector is powered on, if it senses smoke, and if its sensors are too dirty to detect smoke and need cleaning. These test stations activate with the turn of a key so you don’t turn them on by accident.
| Actuator Style | Switch Starting Position | No. of Terminals | Industry Designation | Voltage | Temp. Range, °F | Wire Connection Type | Wd. | Ht. | Mounting Hardware Included | Specifications Met | Each | |
| Key | 1 Off (Normally Open) | 5 | SPST-NO | 24V AC, 24V DC, 120V AC, 230V AC | 32° to 130° | Screw Terminals | 3" | 4 3/4" | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 000000 |
Smoke Detector Guards

Protect your detectors from damage and tampering.
| Dia. | Dp. | Material | Color | Mount Type | Fasteners Included | Specifications Met | Each | |
| 8 1/4" | 2 3/4" | Polyester Coated Steel | White | Surface | Yes | UL Listed | 0000000 | 000000 |
Smoke Detector Testers


Simulate a fire to make sure your smoke detectors are working. These testers release an aerosol that mimics smoke.
Add an extension arm to lift these testers up to hard-to-reach smoke detectors. Attach up to five add-on arms to the extension arm for even more length.
Fire Alarm Control Panels

Connect and monitor your fire alarm system. Control panel comes with all the circuitry needed to power and monitor devices for up to five zones. These devices can include up to 30 smoke or carbon monoxide detectors as well as an unlimited number of heat detectors and fire alarm stations. Indicators show the status of each zone. The control panel has one relay for connecting alarms such as buzzers, bells, and lights.
The control panel requires two 12-volt batteries (not included) for operation; in case of power failure, it will use the batteries as a backup power source.
| For Max. Number of Zones | For Max. Number of Detectors | Ht. | Wd. | Dp. | Material | Color | Electrical Connection | Voltage | Batteries Included | Number of Batteries Required | Battery Size | Specifications Met | Each | |
| 5 | 30 | 19 1/2" | 14 1/4" | 3 3/4" | Steel | Red | Screw Terminals | 120V AC | No | 2 | 12V | UL Listed | 0000000 | 0000000 |


























