Smoke Alarms
At the first sign of smoke, these alarms sound off. They have a built-in smoke detector, so you don’t need to connect them to a fire detection system. Due to import regulations, they cannot be sold to Canada.
Alarms with Wi-Fi connection pair with an app on your smartphone, so you can respond to an emergency even when you’re offsite. They send you notifications if they detect smoke or the battery is running low.
Alarms with tandem signaling can be linked together so that if one detects smoke, they all go off. They install directly into your facility’s electrical system. All have a backup battery to keep them working during power outages.
Alarms with voice alerts don’t just beep—they explain whether there’s smoke or the batteries need changing.

Each | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Volume | Dia. | Dp. | Tandem Signaling Capable | Batteries Included | Mounting Fasteners Included | Includes | Features | Specifications Met | Cannot Be Sold To | Each | |
Replaceable Battery | |||||||||||
| 85 dBA @ 10 ft. | 4" | 1 1/2" | No | Yes | Yes | Dust Cover, Mounting Plate | Hush/Test Button | UL 217, ETL Listed | Canada | 0000000 | 000000 |

| Volume | Dia. | Dp. | Tandem Signaling Capable | Max. No. of Tandem Detectors | Voltage | Wire Connection Type | No. of Wire Leads | Batteries Included | Mounting Fasteners Included | Includes | Features | Specifications Met | Cannot Be Sold To | Each | |
Replaceable Battery | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 85 dBA @ 10 ft. | 5 1/4" | 1 1/2" | Yes | 12 | 120V AC | Wire Leads | 3 | Yes | Yes | Dust Cover, Mounting Plate | Hush/Test Button | UL 217, ETL Listed, California Fire Marshal Approved | Canada | 0000000 | 000000 |
Replaceable Battery—Wi-Fi Connection | |||||||||||||||
| 85 dBA @ 10 ft. | 5" | 2" | Yes | 12 | 120V AC | Wire Leads | 3 | Yes | No | Dust Cover, Mounting Plate, Wire Connector | Hush/Test Button; Voice Alerts: Fire and Low Battery | UL 217, California Fire Marshal Approved | Canada | 0000000 | 00000 |
Nonreplaceable 10 Year Battery | |||||||||||||||
| 85 dBA @ 10 ft. | 6 1/4" | 1 1/2" | Yes | 12 | 120V AC | Wire Leads | 3 | Yes | Yes | Dust Cover, Mounting Plate, Wire Connector | Hush/Test Button; Voice Alerts: Fire, Warning-Carbon Monoxide, and Low Battery | UL 217, ETL Listed, California Fire Marshal Approved | Canada | 0000000 | 00000 |
| Volume | Dia. | Dp. | Tandem Signaling Capable | Max. No. of Tandem Detectors | Voltage | Wire Connection Type | No. of Wire Leads | Batteries Included | Mounting Fasteners Included | Includes | Features | Specifications Met | Cannot Be Sold To | Pkg. Qty. | Pkg. | |
Replaceable Battery | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 85 dBA @ 10 ft. | 5 1/4" | 1 1/2" | Yes | 12 | 120V AC | Wire Leads | 3 | Yes | Yes | Dust Cover, Mounting Plate | Hush/Test Button | UL 217, ETL Listed, California Fire Marshal Approved | Canada | 3 | 0000000 | 000000 |
Nonreplaceable 10 Year Battery | ||||||||||||||||
| 85 dBA @ 10 ft. | 6 1/4" | 1 1/2" | Yes | 12 | 120V AC | Wire Leads | 3 | Yes | Yes | Dust Cover, Mounting Plate, Wire Connector | Hush/Test Button; Voice Alerts: Fire, Warning-Carbon Monoxide, and Low Battery | UL 217, ETL Listed, California Fire Marshal Approved | Canada | 3 | 0000000 | 000000 |

| Dia. | Dp. | Material | Color | Mounting Fasteners Included | Specifications Met | Each | |
| 8 1/4" | 2 3/4" | Polyester-Coated Steel | White | Yes | New York City Approved, UL Listed | 0000000 | 000000 |
Smoke Alarms with Strobe Light

When smoke is present, these alarms warn you with loud beeps and flashing lights. Use them alone or link several together so that if one detects smoke, they all go off in tandem. They install directly into your facility’s electrical system. These alarms also have a backup battery to keep them working during power outages. Due to import regulations, they cannot be sold to Canada.
Smoke Alarms | Guards | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Volume | Electrical Connection | No. of Wire Leads | Voltage | Dia. | Dp. | Max. No. of Tandem Detectors | Batteries Included | Mounting Fasteners Included | Specifications Met | Cannot Be Sold To | Each | Each | ||
| 85 dBA @ 10 ft. | Wire Leads | 3 | 120V AC | 5 1/4" | 2 5/16" | 12 | Yes | Yes | California Fire Marshal Approved, ETL Listed, UL 1638, UL 217 | Canada | 0000000 | 0000000 | 0000000 | 000000 |
Smoke and Carbon Monoxide Alarms
When smoke curls or carbon monoxide rises, these alarms sound off. They have built-in sensors, so you don’t need to connect them to a fire detection system. All have voice alerts that explain why the alarm is sounding.
Alarms with Wi-Fi connection pair with an app on your smartphone, so you can respond to an emergency even when you’re offsite. They send you notifications if they detect a hazard or the battery is running low. These alarms cannot be sold to the listed areas due to product registration requirements.
Alarms with tandem signaling can be linked together so that if one spots smoke or carbon monoxide, they all go off. They install directly into your facility’s electrical system. All have a backup battery to keep them working during power outages.

| Volume | Dia. | Dp. | Tandem Signaling Capable | Max. No. of Tandem Detectors | Mounting Fasteners Included | No. of Wire Leads | Batteries Included | Includes | Features | Specifications Met | Cannot Be Sold To | Each | |
Replaceable Battery | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 85 dBA @ 10 ft. | 6 1/8" | 1 5/8" | Yes | 12 | Yes | 3 | Yes | Dust Cover, Mounting Plate, Wire Connector | Audible Alarm, Hush/Test Button, Voice Alerts: Fire, Warning-Carbon Monoxide, and Low Battery | UL 217, UL 2034, ETL Listed | __ | 0000000 | 000000 |
Replaceable Battery—Wi-Fi Connection | |||||||||||||
| 85 dBA @ 10 ft. | 5" | 1 7/8" | Yes | 12 | No | 3 | Yes | Dust Cover, Mounting Plate, Wire Connector | Audible Alarm, Hush/Test Button, Voice Alerts: Fire, Warning-Carbon Monoxide, and Low Battery | UL 217, UL 2034, California Fire Marshal Approved | Canada | 0000000 | 00000 |
Nonreplaceable 10 Year Battery | |||||||||||||
| 85 dBA @ 10 ft. | 6 1/8" | 1 5/8" | Yes | 12 | Yes | 3 | Yes | Dust Cover, Mounting Plate, Wire Connector | Audible Alarm, Hush/Test Button, Voice Alerts: Fire, Warning-Carbon Monoxide, and Low Battery | UL 217, UL 2034, ETL Listed | __ | 0000000 | 00000 |

| Dia. | Dp. | Material | Color | Mounting Fasteners Included | Specifications Met | Each | |
| 8 1/4" | 2 3/4" | Polyester-Coated Steel | White | Yes | New York City Approved, UL Listed | 0000000 | 000000 |
Smoke Detectors for HVAC Systems

Detect the presence of smoke in ducts and shut down HVAC units to avoid circulation. These sensors and controllers have standard RJ45 connections, so they work with most alarm systems and quickly snap in without needing to connect individual wires to terminals. UL and C-UL listed as well as FM and MEA approved, they meet strict safety standards. Choose from a sensor, controller, or sensor and controller unit.
Sensors measure rapid changes in air flow from smoke and fire but won’t register dust and debris, so they won’t cause a false alarm.
Controllers send signals from your sensor to a fire alarm control panel, which closes HVAC dampers when smoke is detected. Controllers can be installed up to 15 ft. away from your sensors and connected with cable. Connect up to two sensors per controller to monitor two sections of ductwork.
Sensor and controller units come with one controller and one sensor. Connect another sensor to cover another spot in your HVAC system.
Sensors require sampling tubes (sold separately) to bring in air from the duct. Mount the sampling tube inside the duct and connect it to the sensor on the outside of the duct by drilling a hole with the included template. For duct up to 36" wide, the sampling tube’s length should be 2/3 the width of the duct.
If your smoke detectors are hard to access, use remote test stations (sold separately) to check that they’re working properly from a convenient location.

| Lg. | Wd. | Dp. | Max. Number of Tandem Sensors | Wire Connection Type | Output Voltage | Input Voltage | Temp. Range, °F | Mounting Hardware Included | Specifications Met | Each | |
| 8 3/4" | 5 1/2" | 1 7/8" | 30 | Screw Terminals | 18V DC | 24V AC, 24V DC, 120V AC, 230V AC | 0° to 155° | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 0000000 |

| Lg. | Wd. | Dp. | For Max. Number of Sensors | Max. Number of Tandem Controllers | Wire Connection Type | Output Voltage | Input Voltage | Temp. Range, °F | Mounting Hardware Included | Specifications Met | Each | |
| 6 3/4" | 5 1/2" | 1 7/8" | 2 | 15 | Screw Terminals | 18V DC | 24V AC, 24V DC, 120V AC, 230V AC | 0° to 155° | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 0000000 |

| Lg. | Wd. | Dp. | Max. Number of Tandem Controllers | Max. Number of Tandem Sensors | Wire Connection Type | Output Voltage | Input Voltage | Temp. Range, °F | Mounting Hardware Included | Specifications Met | Each | |
| 14 1/2" | 5 1/2" | 1 7/8" | 15 | 30 | Screw Terminals | 18V DC | 24V AC, 24V DC, 120V AC, 230V AC | 0° to 155° | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 0000000 |

Check that your HVAC smoke detector is working properly. Wire these test stations to your smoke detector controller to test difficult to access smoke detectors from a convenient location. Indicator lights show if your smoke detector is powered on, if it senses smoke, and if its sensors are too dirty to detect smoke and need cleaning. These test stations activate with the turn of a key so you don’t turn them on by accident.
| Actuator Style | Switch Starting Position | No. of Terminals | Industry Designation | Voltage | Temp. Range, °F | Wire Connection Type | Wd. | Ht. | Mounting Hardware Included | Specifications Met | Each | |
| Key | 1 Off (Normally Open) | 5 | SPST-NO | 24V AC, 24V DC, 120V AC, 230V AC | 32° to 130° | Screw Terminals | 3" | 4 3/4" | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 000000 |
Heat Alarms

When temperatures get too high, these alarms sound off. Use them in garages, boiler rooms, and other areas where dust, debris, or light smoke can set off false smoke alarms. Wire them directly into your building’s electrical system. You can also link multiple alarms in tandem, so if one detects heat, they all go off. A backup battery keeps them working during power outages.
Mounting Holes | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Activation Temp., °F | Volume | Wire Connection Type | Number of Wire Leads | Voltage | Dia. | Dp. | Max. Number of Tandem Detectors | Batteries Included | Mounting Fasteners Included | Number of | Hole Dia. | Specifications Met | Includes | Each | |