System of Measurement System of Measurement |
---|
|
Cable AWG Cable AWG |
---|
Flexibility Flexibility |
---|
![]() | ![]() |
Ultra Flexible | Flexible |
Wire Type Wire Type |
---|
![]() | |
Use For Use For |
---|
|
Current Current |
---|
Inner Insulation Color Inner Insulation Color |
---|
![]() | Black |
![]() | Blue |
![]() | Green |
![]() | Green/Black |
![]() | Orange |
![]() | Orange/Black |
![]() | Red |
![]() | Red/Black |
![]() | White |
![]() | White/Black |
Shielding Shielding |
---|
![]() | Unshielded |
Outer Insulation Material Outer Insulation Material |
---|
|
OD OD |
---|

Specifications Met Specifications Met |
---|
|
Inner Insulation Marking Inner Insulation Marking |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Wire Finish Wire Finish |
---|
|
Inner Insulation Material Inner Insulation Material |
---|
|
Wire Material Wire Material |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Industry Designation for Cable Insulation
More
About Extension Cords
More
About Wire and Cable
More
About Hazardous Location Environmental Ratings
More
About NEMA Plugs, Sockets, and Receptacles
More
Cable

Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -55° to 220° F
Yellow: -75° to 220° F - Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | 0.34" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 000 | |
18 | 4 | 18/4 | 7 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 00000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.42" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 18 A @ 86° F | 0.5" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.52" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.56" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 2 | 12/2 | 25 A @ 86° F | 0.57" | Black, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 00000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.59" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.64" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.65" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.7" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 3 | 8/3 | 40 A @ 86° F | 0.7" | Black, Green, White | __ | Bare Copper | 0000000 | 0000 | 0000 | |
8 | 4 | 8/4 | 35 A @ 86° F | 0.78" | Black, Green, Red, White | __ | Bare Copper | 0000000 | 0000 | 0000 | |
6 | 3 | 6/3 | 55 A @ 86° F | 0.81" | Black, Green, White | __ | Bare Copper | 00000000 | 0000 | 0000 | |
6 | 4 | 6/4 | 45 A @ 86° F | 0.89" | Black, Green, Red, White | __ | Bare Copper | 00000000 | 0000 | 0000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.41" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.52" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.56" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.64" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.7" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2 | Bare Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | 0.35" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | 0.37" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 7 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 5 | 18/5 | 5 A @ 86° F | 0.47" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 6 | 18/6 | 5 A @ 86° F | 0.5" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 7 | 18/7 | 5 A @ 86° F | 0.52" | Black, Blue, Green, Orange, Red, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 0000 | 0000 | |
18 | 8 | 18/8 | 4 A @ 86° F | 0.53" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 10 | 18/10 | 4 A @ 86° F | 0.6" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.42" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 5 | 16/5 | 8 A @ 86° F | 0.5" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 6 | 16/6 | 8 A @ 86° F | 0.52" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 7 | 16/7 | 8 A @ 86° F | 0.54" | Black, Blue, Green, Orange, Red, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 0000 | 0000 | |
16 | 8 | 16/8 | 7 A @ 86° F | 0.58" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 10 | 16/10 | 5 A @ 86° F | 0.62" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 18 A @ 86° F | 0.51" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.54" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.58" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 5 | 14/5 | 12 A @ 86° F | 0.65" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 6 | 14/6 | 12 A @ 86° F | 0.71" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 0000 | 00 | |
14 | 8 | 14/8 | 10.5 A @ 86° F | 0.81" | Black, Blue, Green, Orange, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 0000 | 00 | |
14 | 10 | 14/10 | 10.5 A @ 86° F | 0.88" | Black, Blue, Green, Green/Black, Orange, Orange/Black, Red, Red/Black, White, White/Black | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 0000 | 00 | |
Per Ft. | |||||||||||
1-249 | 250-Up | ||||||||||
12 | 2 | 12/2 | 25 A @ 86° F | 0.57" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.65" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 5 | 12/5 | 16 A @ 86° F | 0.72" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 6 | 12/6 | 16 A @ 86° F | 0.74" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.62" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.66" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.72" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 5 | 10/5 | 20 A @ 86° F | 0.77" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 0000 | |
10 | 6 | 10/6 | 20 A @ 86° F | 0.88" | Black, Blue, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 0000 | |
8 | 3 | 8/3 | 40 A @ 86° F | 0.85" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 0000 | |
8 | 4 | 8/4 | 35 A @ 86° F | 0.96" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
8 | 5 | 8/5 | 28 A @ 86° F | 0.84" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 0000 | |
6 | 3 | 6/3 | 55 A @ 86° F | 0.98" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
6 | 4 | 6/4 | 45 A @ 86° F | 1.08" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
6 | 5 | 6/5 | 36 A @ 86° F | 1.2" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
4 | 3 | 4/3 | 70 A @ 86° F | 1.14" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 000000 | 00000 | 00 | |
Per Ft. | |||||||||||
1-249 | 250-Up | ||||||||||
4 | 4 | 4/4 | 60 A @ 86° F | 1.26" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
4 | 5 | 4/5 | 48 A @ 86° F | 1.37" | Black, Green, Orange, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
2 | 4 | 2/4 | 80 A @ 86° F | 1.46" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.38" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.4" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.43" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.53" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.58" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.6" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.65" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.66" | Black, Green, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.71" | Black, Green, Red, White | UL Listed, CSA Certified, Flame Rated FT2, Flame Rated FT1 | Tin-Plated Copper | 0000000 | 00000 | 0000 |
Deutsch-Style Power Cords


Use these cords in vehicles and other agricultural and construction equipment. The industry designation is SOOW, so the inner and outer insulation resists oil.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Lg., ft. | Current, A | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Color | Each | |
Plug × Socket | ||||||||||
2 | 6 | 25 | 14 | 0.51" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 000000 |
2 | 12 | 25 | 14 | 0.51" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 00000 |
4 | 6 | 25 | 14 | 0.58" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 00000 |
4 | 12 | 25 | 14 | 0.58" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 000000 |
Abrasion-Resistant Extension Cords for Harsh Environments
Run these cords through high-traffic areas in dirty and greasy environments. They have a thick insulation that resists water, oil, and chemicals, and protects against abrasion.
SOOW cords have both an outer and inner insulation that resists oil, making them more durable than SEOW cords, which only have an outer insulation. SOOW cords also have impact-resistant connectors.







Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
25 ft. | ||||||||||
16 | 15 | 125V AC | Without Power-Indicating Light | 0.39" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 0000000 |
50 ft. | ||||||||||
16 | 15 | 125V AC | Without Power-Indicating Light | 0.39" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
NEMA 5-20 Plug × NEMA 5-20 Socket | ||||||||||
25 ft. | ||||||||||
14 | 18 | 125V AC | Without Power-Indicating Light | 0.5" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
12 | 20 | 125V AC | Without Power-Indicating Light | 0.59" | Rubber | SOOW | UL Listed | Yellow | 00000000 | 000000 |
NEMA 6-20 Plug × NEMA 6-20 Socket | ||||||||||
25 ft. | ||||||||||
14 | 18 | 250V AC | Without Power-Indicating Light | 0.5" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
Extension Cords for Hazardous Locations





Use these cords where ignitable gas and dust may be present. The industry designation is SEOOW, so the inner and outer insulation resists oil.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Environmental Rating | Specifications Met | Color | Each | |
NEMA 5-20 Plug × NEMA 5-20 Socket | ||||||||||||
50 | 10 | 20 | 125V AC | Without Power-Indicating Light | 0.66" | TPE Rubber | SEOOW | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups F, G | CSA Certified | Black | 0000000 | 000000000 |
NEMA 6-20 Plug × NEMA 6-20 Socket | ||||||||||||
50 | 10 | 20 | 250V AC | Without Power-Indicating Light | 0.66" | TPE Rubber | SEOOW | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups F, G | CSA Certified | Black | 0000000 | 00000000 |
Turn-Lock Extension Cords for Harsh Environments









These cords have an oil- and water-resistant insulation and impact-resistant connectors for protection in harsh environments. Give the connectors a quarter turn to lock in place; they remaining secure in high-vibration applications.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA L6-20 Plug × L6-20 Socket | |||||||||||
25 | 14 | 18 | 250V AC | Without Power-Indicating Light | 0.5" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 0000000 |
NEMA L6-30 Plug × L6-30 Socket | |||||||||||
25 | 12 | 25 | 250V AC | Without Power-Indicating Light | 0.56" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
NEMA L16-20 Plug × L16-20 Socket | |||||||||||
25 | 12 | 20 | 480V AC | Without Power-Indicating Light | 0.69" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
NEMA L16-30 Plug × L16-30 Socket | |||||||||||
25 | 10 | 30 | 480V AC | Without Power-Indicating Light | 0.75" | Rubber | SOOW | UL Listed | Yellow | 0000000 | 000000 |
Washdown Straight-Blade Connectors and Cords
All connectors have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. When mated, connectors meet NEMA 6P, NEMA 12, and either IP67 or IP69K.
Connectors that meet IP67 resist temporary submersion.
Plugs mate with female receptacles and female sockets with an attached cover.
Cord splitters power multiple devices from a single outlet.
Note: The current rating of your plug should not exceed that of your socket or receptacle.





Washdown Turn-Lock Connectors and Cords
When mated, connectors meet NEMA 6P for protection against corrosion and washdowns. All have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Plugs mate with female receptacles and female sockets with an attached cover.
Cord splitters power multiple devices from a single outlet.
For technical drawings and 3-D models, click on a part number.





Cords | Caps for Plugs | Replacement Caps for Sockets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Gauge | Cord OD | Industry Designation | End OD | Color | Each | Each | Each | |||
25 ft. Lg. | |||||||||||||
Grounded | |||||||||||||
L5-15 | 125V AC | 15A | 14 | 0.57" | SOOW | 1.9" | Yellow | 00000000 | 0000000 | 000000000 | 000000 | 000000000 | 00000 |
L5-20 | 125V AC | 20A | 14 | 0.57" | SOOW | 2.5" | Yellow | 00000000 | 000000 | 000000000 | 00000 | 000000000 | 00000 |
50 ft. Lg. | |||||||||||||
Grounded | |||||||||||||
L5-15 | 125V AC | 15A | 14 | 0.57" | SOOW | 1.9" | Yellow | 00000000 | 000000 | 000000000 | 00000 | 000000000 | 0000 |
L5-20 | 125V AC | 20A | 14 | 0.57" | SOOW | 2.5" | Yellow | 00000000 | 000000 | 000000000 | 00000 | 000000000 | 00000 |