Tabs on one end snap into grooves in conduit; the other end attaches to a knockout in an outlet box or enclosure. These adapters help seal out air and liquid when used with flexible plastic conduit. All meet IP68 for prolonged submersion and IP69K for high-pressure, high-temperature washdowns. They withstand vibration, are flame retardant, and resist oil, solvents, and UV light.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | Electrical Box Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Thread Size | Pipe Size | Thread Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
NPT | |||||||||||||
1/4 | Snap-In | Female | __ | 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
5/16 | Snap-In | Female | __ | 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
3/8 | Snap-In | Female | __ | 3/8 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
1/2 | Snap-In | Female | __ | 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
3/4 | Snap-In | Female | __ | 3/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 | Snap-In | Female | __ | 1 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/4 | Snap-In | Female | __ | 1 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/2 | Snap-In | Female | __ | 1 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/2 | Snap-In | Female | __ | 2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
Metric | |||||||||||||
1/4 | Snap-In | Female | M12 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
5/16 | Snap-In | Female | M16 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
3/8 | Snap-In | Female | M16 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
1/2 | Snap-In | Female | M20 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 0000 |
3/4 | Snap-In | Female | M25 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 | Snap-In | Female | M32 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/4 | Snap-In | Female | M40 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/2 | Snap-In | Female | M50 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Thread Size | Pipe Size | Thread Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
NPT | |||||||||||||
3/8 | Snap-In | Female | __ | 3/8 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
1/2 | Snap-In | Female | __ | 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | Snap-In | Female | __ | 3/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | Snap-In | Female | __ | 1 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/4 | Snap-In | Female | __ | 1 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/2 | Snap-In | Female | __ | 1 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Metric | |||||||||||||
1/4 | Snap-In | Female | M12 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/8 | Snap-In | Female | M20 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1/2 | Snap-In | Female | M20 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | Snap-In | Female | M25 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | Snap-In | Female | M32 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/4 | Snap-In | Female | M40 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/2 | Snap-In | Female | M50 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Thread Size | Pipe Size | Thread Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
NPT | |||||||||||||
1/4 | Snap-In | Female | __ | 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
5/16 | Snap-In | Female | __ | 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/8 | Snap-In | Female | __ | 3/8 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1/2 | Snap-In | Female | __ | 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | Snap-In | Female | __ | 3/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | Snap-In | Female | __ | 1 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/4 | Snap-In | Female | __ | 1 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/2 | Snap-In | Female | __ | 1 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Metric | |||||||||||||
1/4 | Snap-In | Female | M10 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
5/16 | Snap-In | Female | M12 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/8 | Snap-In | Female | M16 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1/2 | Snap-In | Female | M20 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | Snap-In | Female | M25 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | Snap-In | Female | M32 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Thread Size | Pipe Size | Thread Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
NPT | |||||||||||||
3/8 | Snap-In | Female | __ | 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
1/2 | Snap-In | Female | __ | 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | Snap-In | Female | __ | 3/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | Snap-In | Female | __ | 1 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/4 | Snap-In | Female | __ | 1 1/4 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/2 | Snap-In | Female | __ | 1 1/2 | NPT | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Metric | |||||||||||||
3/8 | Snap-In | Female | M20 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1/2 | Snap-In | Female | M20 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | Snap-In | Female | M25 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | Snap-In | Female | M32 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/4 | Snap-In | Female | M40 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/2 | Snap-In | Female | M50 | __ | Metric | Male | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Connectors for Flexible Plastic Conduit
To join pieces of conduit, these connectors have tabs on the ends that snap into grooves in the conduit. They help seal out air and liquid when used with flexible plastic conduit. All meet IP68 for prolonged submersion and IP69K for high-pressure, high-temperature washdowns. They withstand vibration, are flame retardant, and resist oil, solvents, and UV light.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
3/8 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 000000 |
1/2 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
3/4 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/4 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
1 1/2 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
5/16 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 00000000 | 000000 |
3/8 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL 94 V-0, UL Recognized Component | 0000000 | 00000 |
Reducers for Flexible Plastic Conduit
To connect different sizes of conduit, these reducers have tabs on the ends that snap into grooves in the conduit. They help seal out air and liquid when used with flexible plastic conduit. All meet IP68 for prolonged submersion and IP69K for high-pressure, high-temperature washdowns. They withstand vibration, are flame retardant, and resist oil, solvents, and UV light.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size - 1 | Conduit Trade Size - 2 and - 3 | Conduit Connection Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
1 | 3/4 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
Conduit Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size - 1 | Conduit Trade Size - 2 and - 3 | Conduit Connection Type | Gender | Material | Color | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
5/16 | 1/4 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
3/8 | 5/16 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1/2 | 3/8 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3/4 | 1/2 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 | 3/4 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/4 | 1 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
1 1/2 | 1 1/4 | Snap-In | Female | Nylon | Black | -40° to 245° | IP68, IP69K | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Grommets for Flexible Plastic Conduit
Preventing wear and cracks, these grommets shield the sections of your conduit that rub and bang against nearby components. They’re also known as wear rings and abrasion rings. Use them in applications where machinery vibrates, conduit is dragged across a surface, and robots move dynamically. They have a two-piece construction, so you can attach them to any part of the conduit without disrupting your system. To make sure they stay in place without compressing the conduit and damaging the cables inside, they have internal grooves that hug the conduit’s ridges.
Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Construction | Gender | Material | Color | Specifications Met | Each | |
1/2 | Screw Clamp | Two Piece | Male | Nylon | Black | UL 94 V-0 | 00000000 | 000000 |
3/4 | Screw Clamp | Two Piece | Male | Nylon | Black | UL 94 V-0 | 00000000 | 00000 |
1 | Screw Clamp | Two Piece | Male | Nylon | Black | UL 94 V-0 | 00000000 | 00000 |
1 1/4 | Screw Clamp | Two Piece | Male | Nylon | Black | UL 94 V-0 | 00000000 | 00000 |
1 1/2 | Screw Clamp | Two Piece | Male | Nylon | Black | UL 94 V-0 | 00000000 | 00000 |
Adapters for Choose-a-Color Flexible Plastic Conduit
Tabs on one end snap into grooves in conduit; the other end attaches to a knockout in an outlet box or enclosure.
Adapters with a threaded end require a locknut (not included) to install in unthreaded holes.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | Electrical Box Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | For Knockout Trade Size | Gender | Material | Color | Temperature Range, °F | Specifications Met | Each | |
Snap-In Conduit Connection × Snap-In Electrical Box Connection | |||||||||||
1/2 | Female | __ | __ | 1/2 | Male | PVC | Blue | 0° to 140° | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Female | __ | __ | 3/4 | Male | PVC | Blue | 0° to 140° | UL Listed, CSA Certified | 0000000 | 0000 |
1 | Female | __ | __ | 1 | Male | PVC | Blue | 0° to 140° | UL Listed, CSA Certified | 0000000 | 0000 |
Snap-In Conduit Connection × Threaded Electrical Box Connection | |||||||||||
1/2 | Female | 1/2 | NPT | __ | Male | PVC | Blue | 0° to 140° | UL Listed, CSA Certified | 0000000 | 0000 |
3/4 | Female | 3/4 | NPT | __ | Male | PVC | Blue | 0° to 140° | UL Listed, CSA Certified | 0000000 | 0000 |
1 | Female | 1 | NPT | __ | Male | PVC | Blue | 0° to 140° | UL Listed, CSA Certified | 0000000 | 00000 |
Connectors for Choose-a-Color Flexible Plastic Conduit
Join pieces of conduit by snapping the tabs on each end of these connectors into grooves in the conduit.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Material | Color | Temperature Range, °F | Specifications Met | Each | |
1/2 | Snap-In | Female | PVC | Blue | 0° to 140° F° | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Snap-In | Female | PVC | Blue | 0° to 140° F° | UL Listed, CSA Certified | 0000000 | 0000 |
1 | Snap-In | Female | PVC | Blue | 0° to 140° F° | UL Listed, CSA Certified | 0000000 | 0000 |
Adapters for Flexible Metal Conduit and Armored Cable
Attach flexible metal conduit and types AC and MC armored cable to a knockout in an outlet box or enclosure. Wye adapters join two pieces of conduit or armored cable to one knockout. The snap-in end has tabs that snap into the knockout without locknuts or tools.
The screw-clamp end tightens around conduit with a screw.
For technical drawings and 3-D models, click on a part number.
× Threaded—
With Two Screws
Conduit Connection | For Armored Cable | Electrical Box Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | OD | Type | Pipe Size | Thread Type | For Knockout Trade Size | Gender | Includes | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Snap-In Electrical Box Connection | |||||||||||
3/8 | Female | 0.44"-0.61" | AC, MC | __ | __ | 1/2 | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1/2 | Female | 0.71"-0.91" | AC, MC | __ | __ | 1/2 | Male | __ | UL Listed, CSA Certified | 0000000 | 0000 |
3/4 | Female | 0.84"-1.11" | AC, MC | __ | __ | 3/4 | Male | __ | UL Listed, CSA Certified | 0000000 | 0000 |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||||||
3/8 | Female | 0.44"-0.61" | AC, MC | 1/2 | NPSM | __ | Male | Locknut, Two Screws | UL Listed, CSA Certified | 0000000 | 0000 |
3/8 | Female | 0.56"-0.61" | AC, MC | 1/2 | NPSM | __ | Male | Locknut | UL Listed, CSA Certified | 0000000 | 0000 |
1/2 | Female | 0.86"-0.92" | AC | 1/2 | NPSM | __ | Male | Locknut | UL Listed, CSA Certified | 0000000 | 0000 |
Push-In Conduit Connection × Snap-In Electrical Box Connection | |||||||||||
3/8 | Female | 0.44"-0.61" | AC, MC | __ | __ | 1/2 | Male | __ | UL Listed, CSA Certified | 0000000 | 0000 |
Conduit Connection | For Armored Cable | Electrical Box Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | OD | Type | Pipe Size | Thread Type | Gender | Includes | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||||||
3/8 | Female | 0.45"-0.62" | MC | 1/2 | NPSM | Male | Locknut | UL Listed, CSA Certified | 0000000 | 00000 |
1/2 | Female | 0.75"-0.87" | MC | 1/2 | NPSM | Male | Locknut | UL Listed, CSA Certified | 0000000 | 0000 |
3/4 | Female | 0.87"-1" | MC | 3/4 | NPSM | Male | Locknut | UL Listed, CSA Certified | 0000000 | 0000 |
1 | Female | 1.18"-1.31" | MC | 1 | NPSM | Male | Locknut | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | Female | 1.5"-1.62" | MC | 1 1/4 | NPSM | Male | Locknut | UL Listed, CSA Certified | 0000000 | 00000 |
Conduit Connection | For Armored Cable | Electrical Box Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | OD | Type | Pipe Size | Thread Type | For Knockout Trade Size | Gender | Includes | Specifications Met | Each | |
Push-In Conduit Connection × Snap-In Electrical Box Connection | |||||||||||
3/8 | Female | 0.44"-0.61" | AC, MC | __ | __ | 1/2 | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
Screw-Clamp Conduit Connection × Snap-In Electrical Box Connection | |||||||||||
3/8 | Female | 0.44"-0.61" | AC, MC | __ | __ | 1/2 | Male | __ | UL Listed, CSA Certified | 0000000 | 0000 |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||||||
3/8 | Female | 0.44"-0.61" | AC, MC | 1/2 | NPSM | __ | Male | Locknut | UL Listed, CSA Certified | 0000000 | 0000 |
Grommets for Flexible Metal Conduit and Armored Cable
Also known as antishort bushings, these grommets slide into the ends of conduit and types AC and MC armored cable to protect wire and cable from sharp edges.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | For Armored Cable Gauge (Number of Wires) | For Armored Cable Type | Material | Color | Pkg. Qty. | Pkg. | |
5/16 | Push-In | Female | 14/2, 14/3, 12/2 | AC, MC | Plastic | Red | 100 | 0000000 | 000000 |
3/8 | Push-In | Female | 14/4, 12/3 | AC, MC | Plastic | Red | 100 | 0000000 | 00000 |
7/16 | Push-In | Female | 12/4, 10/2, 10/3 | AC, MC | Plastic | Red | 50 | 0000000 | 00000 |
1/2 | Push-In | Female | 10/4, 8/2, 8/3 | AC, MC | Plastic | Red | 50 | 0000000 | 00000 |
3/4 | Push-In | Female | 8/4, 6/2, 6/3 | AC, MC | Plastic | Red | 50 | 0000000 | 00000 |
1 | Push-In | Female | 1/3, 1/2, 1/0/2, 300 MCM (1), 350 MCM (1), 400 MCM (1), 450 MCM (1), 500 MCM (1) | AC, MC | Plastic | Red | 1 | 00000000 | 0000 |
1 1/4 | Push-In | Female | 1/4, 1/0/4, 2/0/4, 1/0/3, 2/0/3, 3/0/3, 2/0/2, 3/0/2, 600 MCM (1), 650 MCM (1), 700 MCM (1), 750 MCM (1), 800 MCM (1), 900 MCM (1), 4/0/2 | AC, MC | Plastic | Red | 10 | 00000000 | 00000 |
1 1/2 | Push-In | Female | 3/0/4, 4/0/4, 250 MCM (3), 300 MCM (3), 250 MCM (2), 300 MCM (2), 350 MCM (2), 1000 MCM (1) | AC, MC | Plastic | Red | 10 | 00000000 | 00000 |
2 | Push-In | Female | 250 MCM (4), 300 MCM (4), 350 MCM (4), 400 MCM (4), 450 MCM (4), 500 MCM (4), 350 MCM (3), 400 MCM (3), 450 MCM (3), 500 MCM (3), 400 MCM (2), 450 MCM (2), 500 MCM (2) | AC, MC | Plastic | Red | 1 | 00000000 | 0000 |
Connectors for Flexible Metal Conduit
Twist these connectors into two pieces of flexible metal conduit for a quick connection.
Zinc connectors are for light duty applications. 316 stainless steel connectors have superior corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | |||||
---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Specifications Met | Each | |
Zinc | |||||
1/2 | Twist-In | Male | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Twist-In | Male | UL Listed, CSA Certified | 0000000 | 0000 |
1 | Twist-In | Male | UL Listed, CSA Certified | 0000000 | 0000 |
1 1/4 | Twist-In | Male | UL Listed, CSA Certified | 0000000 | 0000 |
1 1/2 | Twist-In | Male | UL Listed, CSA Certified | 0000000 | 0000 |
2 | Twist-In | Male | UL Listed, CSA Certified | 0000000 | 00000 |
316 Stainless Steel | |||||
1/2 | Twist-In | Male | __ | 0000000 | 0000 |
3/4 | Twist-In | Male | __ | 0000000 | 0000 |
1 | Twist-In | Male | __ | 0000000 | 0000 |
Adapters for Flexible Metal Conduit
Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-on end screws onto the OD of conduit. The screw-clamp end tightens around conduit with a screw. The twist-in end attaches to conduit with a few quick turns.
Iron adapters are stronger and more durable than zinc adapters. Aluminum adapters provide some corrosion resistance. 316 stainless steel adapters are the most corrosion resistant.
For technical drawings and 3-D models, click on a part number.
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/4 | Female | 3/4 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 00000 |
1 | Female | 1 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 0000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
1 1/2 | Female | 1 1/2 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
2 | Female | 2 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
Twist-In Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Male | 1/2 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 0000 |
1/2 | Male | 1/2 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 0000 |
3/4 | Male | 3/4 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 0000 |
1 | Male | 1 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 0000 |
1 1/4 | Male | 1 1/4 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | Male | 1 1/2 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 00000 |
2 | Male | 2 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 00000 |
1/2 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 0000 |
3/4 | Female | 3/4 | NPSM | Male | UL Listed | 0000000 | 0000 |
1 | Female | 1 | NPT | Male | UL Listed | 0000000 | 0000 |
1 1/4 | Female | 1 1/4 | NPT | Male | UL Listed | 0000000 | 0000 |
1 1/2 | Female | 1 1/2 | NPT | Male | UL Listed | 0000000 | 00000 |
2 | Female | 2 | NPT | Male | UL Listed | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-On Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
1/2 | Female | 1/2 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 0000 |
3/4 | Female | 3/4 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
1 | Female | 1 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
2 | Female | 2 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | |||||
---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||
3/8 | Female | 1/2 | NPSM | Male | 0000000 | 000000 |
1/2 | Female | 1/2 | NPSM | Male | 0000000 | 00000 |
3/4 | Female | 3/4 | NPSM | Male | 0000000 | 00000 |
1 | Female | 1 | NPSM | Male | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | 0000000 | 00000 |
Twist-In Conduit Connection × Threaded Electrical Box Connection | ||||||
3/8 | Male | 1/2 | NPSM | Male | 0000000 | 00000 |
1/2 | Male | 1/2 | NPSM | Male | 0000000 | 00000 |
3/4 | Male | 3/4 | NPSM | Male | 0000000 | 00000 |
1 | Male | 1 | NPSM | Male | 0000000 | 00000 |
1 1/4 | Male | 1 1/4 | NPSM | Male | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | UL Listed, C-UL Listed | 0000000 | 00000 |
1 1/2 | Female | 1 1/2 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 00000 |
2 | Female | 2 | NPSM | Male | UL Listed, CSA Certified | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 00000 |
1/2 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 0000 |
3/4 | Female | 3/4 | NPSM | Male | UL Listed | 0000000 | 0000 |
1 | Female | 1 | NPSM | Male | UL Listed | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | UL Listed | 0000000 | 00000 |
1 1/2 | Female | 1 1/2 | NPSM | Male | UL Listed | 0000000 | 00000 |
2 | Female | 2 | NPSM | Male | UL Listed | 0000000 | 00000 |
Conduit Connection | Electrical Box Connection | |||||
---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | ||||||
3/8 | Female | 1/2 | NPSM | Male | 0000000 | 000000 |
1/2 | Female | 1/2 | NPSM | Male | 0000000 | 00000 |
3/4 | Female | 3/4 | NPSM | Male | 0000000 | 00000 |
1 | Female | 1 | NPSM | Male | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | 0000000 | 00000 |