Fire-Suppressing Spray Nozzles


FM approved for use in fire-protection applications, these nozzles produce a heavy, coarse spray to quickly put out fires. They come with a protective cover to keep dust and debris from clogging the nozzle’s opening. You don’t have to remove the cover—when water starts flowing, it is blown off the nozzle.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 psi | @ 40 psi | @ 100 psi | @ 400 psi | Orifice Dia. | For Max. Particle Dia. | Overall Wd. | Lg. | Max. Pressure, psi | Max. Temp., °F | Spray Angle | Features | Specifications Met | Each | |
Brass | ||||||||||||||
1/2 NPT Male | ||||||||||||||
4.2 | 6 | 9.5 | 19 | 0.19" | 0.13" | 7/8" | 2 1/2" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 0000000 |
7.5 | 10.6 | 16.8 | 33.6 | 0.27" | 0.13" | 7/8" | 2 1/2" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
11.7 | 16.5 | 26.1 | 52.2 | 0.34" | 0.13" | 7/8" | 2 1/2" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
17 | 24.1 | 38.1 | 76.2 | 0.43" | 0.19" | 7/8" | 2 1/2" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
23.3 | 33 | 52.2 | 104.4 | 0.53" | 0.19" | 7/8" | 2 1/2" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
29.7 | 42 | 66.4 | 132.8 | 0.56" | 0.19" | 7/8" | 2 1/2" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
1 NPT Male | ||||||||||||||
29.7 | 42 | 66.4 | 132.8 | 0.6" | 0.19" | 1 3/8" | 3 5/8" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
47.4 | 67 | 106 | 212 | 0.77" | 1/4" | 1 3/8" | 3 5/8" | 400 | 450° | 120° | Protective Cap | FM Approved, UL Listed | 0000000 | 000000 |
Electric Blowguns for Large Areas

Clear dust and debris, test air ducts for leaks, and dry large surfaces without needing a compressed air line. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Attach the optional vacuum kit (sold separately) to convert the blowgun to a handheld vacuum.
Number of Speeds | Airflow, cfm | Nozzle Lg. | Volume, dBA | Tip OD | O'all Lg. | Body Material | Nozzle Tip Material | Voltage | Cord Lg., ft. | Specifications Met | Each | |
Straight | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 105 | 8" | 93 | 3/4" | 15 1/2" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 000000000 |
1 | 155 | 8" | 92 | 3/4" | 16 1/2" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 00000000 |
2 | 150, 195 | 8" | 93 | 3/4" | 18" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 00000000 |
2 | 150, 195 | 8" | 94 | 3/4" | 18" | Painted Aluminum | Aluminum | 240V AC | 21 | UL Listed | 0000000 | 00000000 |
Vacuum Kits | 0000000 | Each | 0000000 |
Hands-Free Static-Eliminating Blowguns

Bend the stand's flexible arm to position the blowgun and it will stay in place. Step on the included foot pedal to activate airflow and static elimination. Good for electronics assembly and clean room applications, this blowgun requires a clean, dry air supply. It conforms to OSHA Compliant 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Static Neutralizing Distance | Arm Lg. | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | |||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | Not Rated | 1"-36" | 18" | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | C-UL Listed, UL Listed, OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000000 |
Replacement Steel Foot Pedals | 0000000 | Each | 0000000 |
Spray and Stream Nozzles for Fire-Fighting Hose

Twist the barrel to adjust water flow. Nozzles have a textured barrel for grip and a rubber bumper for impact resistance.
Brass nozzles are more durable than aluminum nozzles.
Diesel-Fuel Hose Nozzles



Control the flow while dispensing diesel fuel. Nozzles are aluminum, which is lightweight with good corrosion resistance.
Nozzles with automatic shut-off will stop dispensing when the tank is full or if the nozzle falls from the tank. They have a built-in check valve that reduces spillage when withdrawing the nozzle from tank. Nozzles have an angled design, which reduces hose kinking for efficient fueling. They come with a plastic scuff guard to protect the nozzle from damage.
Nozzles with manual shut-off have a trigger to stop the flow. Do not leave the nozzle unattended when in use.
Nozzles with three-position hold-open clip allow you to dispense fuel without holding the trigger.
Style A is also known as a service-station-style nozzle. The nozzle tip has a stream straightener (also known as a stream shaper), which reduces turbulence for less spillage. Attach an optional splash guard (sold separately) to protect your hands from spray.
Styles B and C are also known as truck-stop nozzles. They have higher flow rates than Style A to dispense large quantities of fuel quickly. Style C includes a splash guard to protect your hands from spray.
Use hold-open clip kits to replace a broken clip. Install with pliers.
For technical drawings and 3-D models, click on a part number.
Nozzles | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Spout | Scuff Guard | Threaded Swivels | Replacement Hold-Open Clip Kits | ||||||||||||||
Style | Max. Flow Rate, gpm | Pipe Size | Connection | Max. Pressure | Temperature Range, °F | OD | Lg. | Material | Color | Shut-Off Type | Specifications Met | Each | Each | Each | |||
Nozzles | |||||||||||||||||
A | 10 | 3/4 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 15/16" | 6 1/2" | Aluminum | Green | Automatic, Manual | UL Listed | 0000000 | 0000000 | 000000 | 00 | 000000 | 00 |
A | 10 | 3/4 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 15/16" | 6 1/2" | Aluminum | Red | Automatic, Manual | UL Listed | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
B | 25 | 1 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 1 1/8" | 6 13/16" | Aluminum | Green | Automatic, Manual | UL Listed | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
Nozzles with Three-Position Hold-Open Clip | |||||||||||||||||
C | 75 | 1 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 1 3/8" | 7" | Aluminum | Green | Automatic, Manual | UL Listed | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
Gasoline Hose Nozzles

These nozzles let you adjust the flow while dispensing gasoline. They are also known as service-station-style nozzles. Nozzles will shut off automatically when the tank is full or if the nozzle falls from the tank. They have a built-in check valve to reduce spillage when withdrawing the nozzle from tank. The nozzle tip has a stream straightener (also known as a stream shaper), which reduces turbulence for less spillage. A plastic scuff guard protects the nozzle from damage. Attach an optional splash guard (sold separately) to protect your hands from spray. Nozzles are aluminum, which is lightweight with good corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Nozzles | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Spout | Threaded Swivels | ||||||||||||
Max. Flow Rate, gpm | Pipe Size | Connection | Max. Pressure | Temperature Range, °F | OD | Lg. | Material | Shut-Off Type | Specifications Met | Each | Each | ||
Nozzles | |||||||||||||
10 | 3/4 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 13/16" | 6 1/2" | Aluminum | Automatic, Manual | UL Listed | 0000000 | 0000000 | 0000000 | 000000 |
Optional Red Splash Guard | 0000000 | Each | 000000 |
Hydraulic Hose Nozzles

Nozzles allow you to control the flow while dispensing hydraulic fluid. They shut off manually, so you’ll have to release the trigger to stop the flow. Nozzles are aluminum, which is lightweight with good corrosion resistance.
Style B is UL listed. It has an angled design, which reduces hose kinking for efficient fueling.
Warning: Do not leave nozzles unattended when in use.
For technical drawings and 3-D models, click on a part number.
Spout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Max. Flow Rate, gpm | Pipe Size | Connection | Max. Pressure | Temperature Range, °F | OD | Lg. | Material | Shut-Off Type | Specifications Met | Each | |
B | 40 | 3/4 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 13/16" | 6" | Aluminum | Manual | UL Listed | 0000000 | 000000 |
B | 40 | 1 | Threaded NPT Female | 50 psi @ 72° F | -20° to 125° | 13/16" | 6" | Aluminum | Manual | UL Listed | 0000000 | 00000 |
Aluminum Barbed Swivel (1 Pipe Size) for Style B | 0000000 | Each | 000000 |
Enclosure-Cooling Vortex Tubes with Thermostats

Set the thermostat and these vortex tubes switch on only when needed. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Replacement filters are sold separately.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Frequency | Dia. | Ht. | For Opening Dia. | Each | Each | ||
With Adjustable Thermostat (50° to 140° F) | ||||||||||||||||
Aluminum—NEMA 12 | ||||||||||||||||
400 | 5 | 1/8 | NPT | Male | 80-100 | 53 | 120V AC | Wire Leads | 60Hz | 7/8" | 7 1/16" | 1 1/8" | 0000000 | 000000000 | 0000000 | 0000000 |
900 | 15 | 1/4 | NPT | Female | 80-100 | 75 | 120V AC | Wire Leads | 60Hz | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 00000000 | 0000000 | 000000 |
1,500 | 25 | 1/4 | NPT | Female | 80-100 | 75 | 120V AC | Wire Leads | 60Hz | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 85 | 120V AC | Wire Leads | 60Hz | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 00000000 | 0000000 | 000000 |
Low-Noise Enclosure-Cooling Vortex Tubes with Thermostats

Often used in low-noise environments such as labs and clean rooms, these are quieter than standard enclosure-cooling vortex tubes. Set the thermostat and the tubes switch on only when needed. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Vortex tubes with dual air outlets have a higher cooling capacity than other vortex tubes. Use them to cool large enclosures and electronics that generate significant heat. Direct the two air streams independently for targeted cooling. With two air mufflers and two ducting lines, these vortex tubes take up slightly more space in your enclosure than vortex tubes with one air outlet.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume | Ht. | Wd. | Dp. | Environmental Rating | Includes | Each | Each | ||
With Nonadjustable Thermostat (80° to 90° F) | |||||||||||||||
Plastic—NEMA 12 | |||||||||||||||
900 | 15 | 3/8 | NPT | Female | 90-100 | 60 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Ducting Kit, Inline Compressed Air Filter | 0000000 | 0000000 | 0000000 | 0000000 |
1,500 | 25 | 3/8 | NPT | Female | 90-100 | 66 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Ducting Kit, Inline Compressed Air Filter | 0000000 | 000000 | 0000000 | 000000 |
2,500 | 35 | 3/8 | NPT | Female | 90-100 | 72 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Ducting Kit, Inline Compressed Air Filter | 0000000 | 000000 | 0000000 | 000000 |
5,000 | 70 | 3/8 | NPT | Female | 90-100 | 75 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Dual Air Outlets, Ducting Kit, Inline Compressed Air Filter | 0000000 | 00000000 | 0000000 | 000000 |
Enclosure-Cooling Vortex Tubes

Vortex tubes convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Dia. | Ht. | For Opening Dia. | Each | Each | ||
Aluminum—NEMA 12 | |||||||||||||
400 | 5 | 1/8 | NPT | Male | 80-100 | 53 | 7/8" | 7 1/16" | 1 1/8" | 0000000 | 0000000 | 0000000 | 0000000 |
900 | 15 | 1/4 | NPT | Female | 80-100 | 75 | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 000000 | 0000000 | 000000 |
1,500 | 25 | 1/4 | NPT | Female | 80-100 | 75 | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 85 | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 000000 | 0000000 | 000000 |
Washdown Enclosure-Cooling Vortex Tubes with Thermostats

Set the thermostat and these vortex tubes switch on only when needed. Suitable for washdown applications, they are NEMA rated to resist washdowns. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure.
NEMA 4 rated vortex tubes resist dirt and washdowns.
NEMA 4X rated vortex tubes resist dirt, washdowns, and corrosion.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume | Dia. | Ht. | For Opening Dia. | Each | Each | ||
Aluminum—NEMA 4 | |||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 60 dBA to 79 dBA | 2 1/8" | 6 3/4" | 1 15/16" | 0000000 | 000000000 | 0000000 | 0000000 |
1,500 | 25 | 1/4 | NPT | Female | 80-100 | 60 dBA to 79 dBA | 2 1/8" | 6 3/4" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 60 dBA to 79 dBA | 2 1/8" | 6 3/4" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Frequency | Dia. | Ht. | For Opening Dia. | Each | Each | ||
304 Stainless Steel—NEMA 4X | ||||||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 71 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 000000000 | 0000000 | 0000000 |
1,700 | 25 | 1/4 | NPT | Female | 80-100 | 84 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Aluminum—NEMA 4 | ||||||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 71 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
1,700 | 25 | 1/4 | NPT | Female | 80-100 | 84 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Low-Noise Washdown Enclosure-Cooling Vortex Tubes with Thermostats
In addition to being quieter than standard enclosure-cooling vortex tubes, these stand up to washdowns and weather. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. Set the thermostat and the tubes switch on only when needed. All include a ducting kit to distribute cool air throughout the enclosure and air mufflers to reduce noise. They also have an inline compressed air filter, which prevents moisture from building up inside the enclosure to further safeguard electronics.
Vortex tubes with dual air outlets have a higher cooling capacity than other vortex tubes. Use them to cool large enclosures and electronics that generate a lot of heat. Direct the two air streams independently for targeted cooling. With two air mufflers and two ducting lines, these vortex tubes take up more space than vortex tubes with one air outlet.
Vortex tubes with an electric thermostat require a 120V AC outlet. Those with an internal outlet are best for areas where external outlets are not available or where it would be unsafe to have an external electrical connection. Choose those with an external outlet if you need separate electrical connections for the thermostat and the electronics within an enclosure. Replacement filters are sold separately.


Air Inlet | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Ht. | Wd. | Dp. | For Opening Dia. | Environmental Rating | Features | Each | |
Plastic—NEMA 4 | ||||||||||||||
900 | 15 | 3/8 | NPT | Female | 90-100 | 60 | 8" | 4 3/4" | 5 3/8" | 1 15/16" | NEMA 4 | __ | 0000000 | 000000000 |
1,500 | 25 | 3/8 | NPT | Female | 90-100 | 66 | 8" | 4 3/4" | 5 3/8" | 1 15/16" | NEMA 4 | __ | 0000000 | 00000000 |
2,500 | 35 | 3/8 | NPT | Female | 90-100 | 72 | 8" | 4 3/4" | 5 3/8" | 1 15/16" | NEMA 4 | __ | 0000000 | 00000000 |
5,000 | 70 | 3/8 | NPT | Female | 90-100 | 75 | 6 3/8" | 9 1/2" | 5 1/2" | 1 15/16" | NEMA 4 | Dual Air Outlets | 0000000 | 00000000 |

Air Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Ht. | Wd. | Dp. | For Opening Dia. | Environmental Rating | Each | |
Internal Outlet | |||||||||||||||
Plastic—NEMA 4X | |||||||||||||||
900 | 15 | 3/8 | NPT | Female | 40-150 | 62-68 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 000000000 |
1,500 | 25 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
2,500 | 35 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
External Outlet | |||||||||||||||
Plastic—NEMA 4X | |||||||||||||||
900 | 15 | 3/8 | NPT | Female | 40-150 | 62-68 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
1,500 | 25 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
2,500 | 35 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
Washdown Enclosure-Cooling Vortex Tubes

Suitable for washdown applications, these vortex tubes are NEMA rated to resist washdowns. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure.
NEMA 4 rated vortex tubes resist dirt and washdowns.
NEMA 4X rated vortex tubes resist dirt, washdowns, and corrosion.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Ht. | Dia. | For Opening Dia. | Each | Each | ||
Aluminum—NEMA 4 | |||||||||||||
900 | 15 | 3/8 | NPT | Female | 80-100 | 71 | 9 15/16" | 2" | 1 15/16" | 0000000 | 0000000 | 0000000 | 0000000 |
1,500 | 25 | 3/8 | NPT | Female | 80-100 | 84 | 9 15/16" | 2" | 1 15/16" | 0000000 | 000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
304 Stainless Steel—NEMA 4X | |||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 71 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
1,700 | 25 | 1/4 | NPT | Female | 80-100 | 84 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |