About Noise, Filtration, and Flow Ratings
More
About Duct Connections
More
Weather-Resistant Breather Vents
Shield outdoor pipe and tank openings from the environment. Also known as vent caps, these breather vents have screens to allow air flow while blocking debris. Use them to prevent excess vacuum and pressure in your equipment.
For technical drawings and 3-D models, click on a part number.


Screen | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Style | Pipe Size | Ht. | Dia. | For Use With | Material | Construction | Mesh Size | Removes Particle Size Down To, microns | Each | |
NPT Male | ||||||||||
Zinc-Plated Steel Body and Fitting | ||||||||||
A | 3/8 | 1 1/4" | 1 1/4" | Air | 304 Stainless Steel | Wire Mesh | 100 | 140 | 00000000 | 000000 |
A | 1/2 | 1 7/16" | 1 1/4" | Air | 304 Stainless Steel | Wire Mesh | 100 | 140 | 00000000 | 00000 |
NPT Female | ||||||||||
Zinc-Plated Iron Body and Fitting | ||||||||||
B | 3/4 | 1 3/16" | 1 13/16" | Air | 304 Stainless Steel | Wire Mesh | 30 | 880 | 00000000 | 00000 |
B | 1 | 1 5/16" | 2 1/4" | Air | 304 Stainless Steel | Wire Mesh | 30 | 880 | 00000000 | 00000 |
B | 1 1/2 | 1 1/2" | 3 1/8" | Air | 304 Stainless Steel | Wire Mesh | 30 | 880 | 00000000 | 00000 |
B | 1 1/4 | 1 3/8" | 2 3/4" | Air | 304 Stainless Steel | Wire Mesh | 30 | 880 | 00000000 | 00000 |
B | 2 | 1 11/16" | 3 7/8" | Air | 304 Stainless Steel | Wire Mesh | 30 | 880 | 00000000 | 00000 |
B | 3 | 2 1/2" | 5 1/2" | Air | 304 Stainless Steel | Wire Mesh | 30 | 880 | 00000000 | 00000 |
B | 4 | 2 1/2" | 6 1/2" | Air | 304 Stainless Steel | Wire Mesh | 20 | 864 | 00000000 | 000000 |
Breather Vents

Protect against excess vacuum and pressure in cylinders, gear boxes, enclosures, manifolds, and tanks. You can also use these breather vents to block debris from entering equipment.
Style G has a slotted drive for installation with a screwdriver.
For technical drawings and 3-D models, click on a part number.
Style | Thread Size | Max. Flow Rate | Max. Pressure, psi | Max. Temp., °F | Ht. | Dia. | For Use With | Removes Particle Size Down To, microns | Each | |
UNF Male | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
316 Stainless Steel Body and Fitting | ||||||||||
G | 10-32 | 10 scfm @ 100 psi | 100 | 750° | 7/16" | 3/16" | Air, Inert Gas | 10 | 0000000 | 000000 |
UNC Male | ||||||||||
316 Stainless Steel Body and Fitting | ||||||||||
G | 3/8"-16 | 50 scfm @ 100 psi | 100 | 750° | 1" | 3/8" | Air, Inert Gas | 10 | 0000000 | 00000 |
G | 5/16"-18 | 25 scfm @ 100 psi | 100 | 750° | 1 7/16" | 5/16" | Air, Inert Gas | 10 | 0000000 | 00000 |
Lockable Breather Vents with Cap
Secure access to vented openings in pipe and tanks—the cap can be locked to prevent tampering. These breather vents allow you to add a filling port to your hydraulic tank while protecting against excess pressure and vacuum. Use them to stop debris from entering your tank. Breather vents mount on top of standard tank openings with included hardware. Padlock is not included.
For technical drawings and 3-D models, click on a part number.


Material | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | Max. Temp., °F | Ht. | Dia. | For Use With | Cap | Screen | For Max. Padlock Shackle Dia. | Each | |
NPT Male | |||||||||
2 | 200° | 4 1/2" | 5 5/8" | Air, Oil, Water | Aluminum | Stainless Steel | 3/8" | 0000000 | 000000 |
Breather Vents with Cap
Add a filling port to your hydraulic tank while protecting against excess pressure and vacuum. Breather vents stop debris from entering your tank. Mount them on top of standard tank openings with included hardware.
For technical drawings and 3-D models, click on a part number.


Vents | Replacement Screens | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Opening Dia. | Max. Flow Rate, gpm | Max. Temp., °F | Ht. | For Use With | Screen Material | Mount Type | Number of Bolt Holes | Bolts Included | Removes Particle Size Down To, microns | Each | Each | ||
Steel Body | |||||||||||||
304 Stainless Steel Cap | |||||||||||||
2 1/8" | 20 | 220° | 5" | Air, Oil | 304 Stainless Steel | Flange | 6 | Yes | 40 | 0000000 | 000000 | 0000000 | 000000 |
Steel Cap | |||||||||||||
2 1/8" | 192 | 250° | 5 1/8" | Air, Oil | 304 Stainless Steel | Flange | 6 | Yes | 40 | 0000000 | 00000 | 0000000 | 0000 |


Vents | Replacement Screens | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Opening Dia. | Max. Flow Rate, gpm | Max. Temp., °F | Ht. | For Use With | Screen Material | Mount Type | Number of Bolt Holes | Bolts Included | Removes Particle Size Down To, microns | Each | Each | ||
Steel Body | |||||||||||||
304 Stainless Steel Cap | |||||||||||||
2 1/8" | 20 | 220° | 5 3/4" | Air, Oil | Nylon Plastic | Flange | 6 | Yes | 40 | 0000000 | 000000 | 0000000 | 000000 |
Steel Cap | |||||||||||||
2 1/8" | 115 | Not Rated | 5 1/8" | Air, Oil | 304 Stainless Steel | Flange | 6 | Yes | 10 | 00000000 | 00000 | 0000000 | 0000 |


Vents | Replacement Screens | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Opening Ht. | For Opening Wd. | Max. Flow Rate, gpm | Max. Temp., °F | Ht. | Wd. | Dp. | For Use With | Screen Material | Mount Type | Number of Bolt Holes | Bolts Included | Removes Particle Size Down To, microns | Each | Each | ||
Nylon Plastic Body | ||||||||||||||||
Steel Cap | ||||||||||||||||
3 1/2" | 3" | 115 | Not Rated | 6 1/8" | 4 5/8" | 4" | Air, Oil | 304 Stainless Steel | Flange | 7 | Yes | 10 | 00000000 | 000000 | 0000000 | 00000 |
3 1/2" | 3" | 192 | Not Rated | 6 1/8" | 4 5/8" | 4" | Air, Oil | 304 Stainless Steel | Flange | 7 | Yes | 40 | 00000000 | 00000 | 0000000 | 0000 |
Corrosion-Resistant Breather Vents



These breather vents withstand corrosion in damp environments. Use them to prevent excess vacuum and pressure in cylinders, gear boxes, and tanks and to block debris from entering equipment.
Stainless steel breather vents stand up to higher temperatures than polyethylene breather vents. Those with a Viton® fluoroelastomer O-ring offer extra protection against leaks. 316 stainless steel breather vents resist corrosion better than 303 and 304 stainless steel breather vents.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Size | Max. Flow Rate | Max. Pressure, psi | Max. Temp., °F | Ht. | For Use With | O-Ring Material | Removes Particle Size Down To, microns | Each | |
NPT Male | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
304 Stainless Steel Body and Fitting | ||||||||||
1/8 | __ | 26 scfm @ 100 psi | 150 | 400° | 1/2" | Air, Inert Gas | __ | 100 | 0000000 | 00000 |
1/4 | __ | 35 scfm @ 100 psi | 150 | 400° | 11/16" | Air, Inert Gas | __ | 100 | 0000000 | 00000 |
3/8 | __ | 87 scfm @ 100 psi | 150 | 400° | 13/16" | Air, Inert Gas | __ | 100 | 0000000 | 00000 |
1/2 | __ | 131 scfm @ 100 psi | 150 | 400° | 15/16" | Air, Inert Gas | __ | 100 | 0000000 | 00000 |
3/4 | __ | 219 scfm @ 100 psi | 150 | 400° | 15/16" | Air, Inert Gas | __ | 100 | 0000000 | 00000 |
1 | __ | 306 scfm @ 100 psi | 150 | 400° | 1 3/16" | Air, Inert Gas | __ | 100 | 0000000 | 00000 |
UNF Male | ||||||||||
303 Stainless Steel Body and Fitting | ||||||||||
__ | 10-32 | Not Rated | 250 | 400° | 7/16" | Air, Inert Gas | Viton® Fluoroelastomer Rubber | 40 | 0000000 | 00000 |
316 Stainless Steel Body and Fitting | ||||||||||
__ | 10-32 | Not Rated | 250 | 400° | 7/16" | Air, Inert Gas | Viton® Fluoroelastomer Rubber | 40 | 0000000 | 00000 |
Metric Male | ||||||||||
316 Stainless Steel Body and Fitting | ||||||||||
__ | M5 | Not Rated | 250 | 400° | 7/16" | Air, Inert Gas | Viton® Fluoroelastomer Rubber | 40 | 0000000 | 00000 |
Washdown Weather-Resistant Breather Vents

These breather vents are rated NEMA 6 to withstand periodic submersion in water. Install them in enclosures to stop the buildup of pressure and vacuum and to prevent debris from entering equipment. Breather vents can be used with enclosures that are rated NEMA 4, 12, and 13 for washdown environments and splashing oil and coolant.
For technical drawings and 3-D models, click on a part number.
Thread Size | Max. Pressure, psi | Max. Temp., °F | Ht. | Dia. | For Use With | O-Ring Material | Removes Particle Size Down To, microns | Each | |
Threaded Metric Male | |||||||||
---|---|---|---|---|---|---|---|---|---|
303 Stainless Steel Body and Fitting | |||||||||
M3 | 1.4 | 158° | 5/16" | 1/4" | Air | EPDM Rubber | 3 | 0000000 | 000000 |
Self-Draining Breather Vents

Minimize moisture buildup in enclosures. Also known as drain plugs, these breather vents have a small outlet that allows condensation to drain. They have a silicone O-ring above the threads for a tight seal. Install them at the lowest point of the enclosure. Breather vents meet IP66 for protection in washdown environments. Use them to prevent excess vacuum and pressure in cylinders, gear boxes, and tanks and to block debris from entering equipment.
316 stainless steel breather vents have excellent corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Standard Duct and Fittings

No need for clamps or connectors—duct and fittings press-fit together. Male ends are crimped or tapered, making them slightly smaller than a female end for simple assembly.
304 stainless steel is more corrosion resistant than steel and aluminum.
For technical drawings and 3-D models, click on a part number.
Spark-Protection Chimney Vent Caps

The expanded mesh on these vent caps provides spark protection. They cover chimneys to reduce downdrafts and prevent obstructions from entering.
304 stainless steel caps are corrosion resistant.
For technical drawings and 3-D models, click on a part number.
For Duct | 304 Stainless Steel | |||||||
---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Ht. | Wd. | Lg. | Gauge | Connection Type | Each | |
For Square Duct | ||||||||
11 1/2"-13 1/2" | 11 1/2"-13 1/2" | 8" | 13 1/2" | 11 1/2" | 22 | Press Fit | 0000000 | 0000000 |
High-Temperature Chimney Vents and Fittings
Built to withstand temperatures up to 1000° F, these vent pipes and fittings are for use with boilers, furnaces, stoves, and other equipment that is fired by gas, oil, wood, or coal.
To join pipes and connectors, twist a male end into a female end and secure with the included locking band.
Hazardous Location Threaded Breather Vents

Safe for use around flammable and combustible gases, vapors, fibers, and dust, these vents allow air to flow through enclosures to maintain consistent pressure and reduce moisture buildup as temperatures change. They also stand up to washdowns. Made from 303 stainless steel, these vents will not corrode from salt water and chemicals.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | For Hole Diameter | Head Diameter | Protection Type | Environmental Rating | Specifications Met | UL File Number | Each | |
303 Stainless Steel | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2 | NPT | 7/8" | 7/8" | Dust-Ignition Proof, Explosion Proof | NEMA 4X; NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G; NEC Class III Divisions 1, 2 | UL Listed | E34997 | 0000000 | 0000000 |
Hazardous Location Drain Vents

Safe for use around hazardous gasses and dust, these vents maintain steady pressure and prevent moisture buildup from temperature changes inside enclosures. They allow air to flow through the enclosures while protecting the contents from washdowns, dirt, and weather. Install these vents at the lowest point on an enclosure, so moisture can drip out.
Increased-safety drains keep sparks, high temperatures, or current creepage inside an enclosure, so they won’t ignite flammable gasses and dust.
Flameproof drains reduce the risk of igniting flammable gasses and dust if an explosion occurs within the enclosure.
316 stainless steel drains stand up to corrosion. They’re best for areas with salt water.
For technical drawings and 3-D models, click on a part number.
Thread Size | Thread Pitch, mm | Height | Environmental Rating | Nut Material | O-Ring Material | Maximum Temperature, °F | Specifications Met | Each | |
Increased-Safety Drains | |||||||||
---|---|---|---|---|---|---|---|---|---|
316 Stainless Steel | |||||||||
M20 | 1.5 | 1" | NEMA 4X; IP66; NEC Class I Division 2 Groups A, B, C, D | 316 Stainless Steel | Buna-N Rubber | 185° | ATEX Ex e IIC Gb ATEX Ex tb IIIC Db IECEx Ex e IIC Gb IECEx Ex tb IIIC Db | 0000000 | 0000000 |
M25 | 1.5 | 1 5/16" | NEMA 4X; IP66; NEC Class I Division 2 Groups A, B, C, D | 316 Stainless Steel | Buna-N Rubber | 185° | ATEX Ex e IIC Gb ATEX Ex tb IIIC Db IECEx Ex e IIC Gb IECEx Ex tb IIIC Db | 000000 | 000000 |
Flameproof Drains | |||||||||
316 Stainless Steel | |||||||||
M20 | 1.5 | 1" | NEMA 4X; IP66; NEC Class I Division 2 Groups A, B, C, D | __ | Silicone Rubber | 300° | ATEX Ex d IIC Gb ATEX Ex e IIC Gb ATEX Ex tb IIIC Db IECEx Ex d IIC Gb IECEx Ex e IIC Gb IECEx Ex tb IIIC Db | 0000000 | 000000 |
M25 | 1.5 | 1 5/16" | NEMA 4X; IP66; NEC Class I Division 2 Groups A, B, C, D | __ | Silicone Rubber | 300° | ATEX Ex d IIC Gb ATEX Ex e IIC Gb ATEX Ex tb IIIC Db IECEx Ex d IIC Gb IECEx Ex e IIC Gb IECEx Ex tb IIIC Db | 0000000 | 000000 |
Hazardous Location Enclosure Drains

Safe for use around flammable and combustible gases, vapors, fibers, and dust, these drains let moisture buildup from temperature changes inside enclosures drip out to keep electronics dry. Mount them at the bottom of enclosures.
1/2 pipe-size drains also stand up to washdowns and weather.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | Drive Style | Hex Size | Head Diameter | Height | Material | Protection Type | Environmental Rating | UL File Number | CSA File Number | Specifications Met | Each | |
3/8 | NPT Male | External Hex | 7/8" | 15/16" | 1 3/4" | 303 Stainless Steel | Dust-Ignition Proof, Explosion Proof | NEC Class I Divisions 1, 2 Groups C, D;NEC Class II Divisions 1, 2 Groups E, F, G;NEC Class III Divisions 1, 2 | E34997 | 065181_0_000 | UL Listed, CSA Certified, UL 886 | 00000000 | 000000 |
1/2 | NPT Male | External Hex | 7/8" | 15/16" | 1 3/4" | 304 Stainless Steel | Dust-Ignition Proof, Explosion Proof | NEMA 4X;NEC Class I Divisions 1, 2 Groups B, C, D;NEC Class II Divisions 1, 2 Groups E, F, G;NEC Class III Divisions 1, 2 | E34997 | 065181_0_000 | UL Listed, CSA Certified, UL 886 | 00000000 | 000000 |