Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | Plug | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 6 | 3 5/8" | 2 7/8" | 3 1/2" | 0000000 | 0000000 |
A | Plug | 5 | 4 | 2.2 | 12.2 | 35° to 120° | 1/40 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4 1/4" | 2 7/8" | 4 7/8" | 0000000 | 000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
B | Plug | 5.6 | 4.3 | 0.8 | 11.1 | 35° to 85° | 1/15 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4" | 3 7/8" | 5 3/8" | 0000000 | 000000 |
B | Plug | 8.9 | 6.9 | 2.5 | 13 | 35° to 85° | 1/10 hp | 1.2 | Screened | 1/2 | NPT | Male | 6 | 4 1/2" | 4" | 5 5/8" | 0000000 | 00000 |
115V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
B | Plug | 3.5 | 1.5 | __ | 7.1 | 35° to 85° | 1/25 hp | 0.5 | Screened | 1/4 | NPT | Male | 6 | 3 7/8" | 3 1/2" | 4 5/8" | 0000000 | 00000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Plug | 3.5 | 2.5 | __ | 10.2 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 18 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Hardwire | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 0.7 | Screened | 1/4 | NPT | Male | 12 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
D | Plug | 7.9 | 6.6 | 3.4 | 13.4 | 35° to 120° | 1/28 hp | 1.4 | Screened | 3/8 | NPT | Male | 6 | 4" | 4" | 4 5/8" | 0000000 | 0000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
E | Plug | 20 | 12 | 4 | 15 | 35° to 85° | 1/15 hp | 1 | Screened | 3/4 | NPT | Male | 15 | 5 1/4" | 3 3/4" | 6 3/8" | 00000000 | 0000000 |
Submersible/Open-Air Pumps for Water
These pumps can be submerged or connected remotely to a pipe in your line. Use them to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
2.8 | 1.7 | 7 | 35° to 120° | 1/125 hp | 0.6 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 3 3/8" | 3 3/4" | 2 3/4" | 0000000 | 0000000 |
Impact-Resistant Submersible/Open-Air Pumps for Water
Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Features | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 1.1 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 4 1/8" | 4 5/8" | __ | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 000000 | 000000 |
B | 8.3 | 5.6 | 3.5 | 17.3 | 35° to 120° | 1/15 hp | 3.2 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 0.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 0000000 | 000000 |
B | 10 | 8.6 | 6.9 | 21 | 35° to 120° | 1/15 hp | 1.4 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 0000000 | 000000 |
Impact-Resistant Submersible Pumps for Water
The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
A | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/200 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 3.5 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 0.4 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 1.6 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 0000000 | 000000 |
Extended-Life Submersible/Open-Air Pumps for Water
These pumps can be submerged or connected remotely to a pipe in your line. Magnets turn the impeller so there's no shaft seal to wear out. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug | 2.3 | 2 | 1.5 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 3/8" | Barbed | 3/8" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 1/2" | Barbed | 1/2" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 000000 |
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | 1/4 | NPT | Male | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Extended-Life Submersible Pumps for Water
Magnets turn the impeller so there's no shaft seal to wear out. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Screened | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 3 7/8" | 0000000 | 0000000 |
High-Head Submersible Pumps for Water
Also known as deep-well submersible pumps, use these pumps to transfer drinking water from wells and cisterns up to 250 ft. deep. They are activated by a pressure switch and must be hardwired. Do not run dry.
For technical drawings and 3-D models, click on a part number.
Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Removes Water Down To, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Ht. | Specifications Met | Each | |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
14.7 | 309.5 | 250 | 68° to 104° | 1 7/16 hp | 13.1 | Screened | 1 1/4 | NPT | Female | 3 15/16" | 31 3/8" | NSF/ANSI 61, UL Listed | 0000000 | 000000000 |
16.4 | 223.5 | 250 | 68° to 104° | 1 1/2 hp | 13.1 | Screened | 1 1/2 | NPT | Female | 3 15/16" | 27 3/16" | NSF/ANSI 61, UL Listed | 0000000 | 00000000 |
Submersible Pumps for Cutting Oil
Submerge these pumps to circulate machine and cutting oil with a viscosity up to 9 centipoise. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 3 Ft. of Head | @ 5 Ft. of Head | @ 7 Ft. of Head | Max. Ft. of Head, ft. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
5 | 4.3 | 3.4 | 2.5 | 11.8 | 9 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 5/8" | 3 1/2" | 5 3/4" | 0000000 | 0000000 |
Submersible Pumps for Chemicals
These pumps circulate solvent-based parts-washing solutions. Submerge in solutions that are UL classified as PJQU (flash point no lower than 100° F). Pumps must be wired to a plug (not included) to activate. Do not run dry. Not for use in heated parts washer applications.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 3 Ft. of Head | @ 5 Ft. of Head | @ 7 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
A | 5 | 4.3 | 3.4 | 2.5 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 0000000 | 0000000 |
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
A | 2.8 | 2.3 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 3 5/8" | 2 3/4" | 3 1/4" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 0.6 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
Submersible Pumps for Salt Water
Circulate salt water in submerged and open-air applications. These pumps use magnets to turn the impellers so there is no shaft seal to wear out. They must be wired to a plug (not included) to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
5 | 3.8 | 13 | 35° to 130° | 1/50 hp | 0.9 | 3/8 × 3/4 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 6 1/8" | 4 7/8" | 00000000 | 0000000 |
8.5 | 8 | 19 | 35° to 130° | 1/20 hp | 2 | 3/4 | NPT | Female | 1/2 | NPT | Male | 4 7/8" | 7 3/8" | 4 3/4" | 00000000 | 000000 |