    38 Products

    Hazardous Location Limit Switches

    Image of Product. Front orientation. Contains Annotated. Limit Switches. Hazardous Location Limit Switches, Plunger Actuator.
    Image of Product. Front orientation. Contains Annotated. Limit Switches. Hazardous Location Limit Switches, Wobble Stick Actuator.

    Plunger Actuator

    Wobble Stick

    Actuator

    Safely open or close a circuit near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. You'll know they're safe because they're NEC Class I, Divisions 1, 2 Groups B, C, and D; and Class II, Divisions 1, 2 Groups E, F, and G certified for hazardous locations. These switches send a signal to your circuit when an object hits the actuator—for instance, a box on a conveyor runs into the switch, stopping the conveyor. They open and close circuits as fast as snap-acting switches, but they have a bigger actuator for large objects.
    Plunger Actuator—Switches with a plunger actuator let you adjust the actuator’s height to easily align it with your target. They require a push to activate, similar to a button.
    Wobble Stick Actuator—Switches with a wobble stick actuator have an arm that rotates 360°, so you don’t need to align it in a specific direction. The actuator won’t snap if pushed backward, such as if there’s a jam in your system.
    Housing
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Actuation Torque,
    in·ozf
    Operating
    Temp. Range, ° F
    Actuator
    Ht.
    No. of
    Terminals
    Lg.
    Ht.
    Dp.
    Housing
    Material
    Conduit
    Trade Size
    Enclosure Rating
    Each
    Plunger Actuator
     
    Screw-Terminal Wire Connection
    11 Off or 1 On
    Momentary
    SPDT
    10 amp @ 600V AC, 2.5 amp @ 600V DC600V AC
    600V DC
    0 to 1852.7" to 2.9"42.7"4.1"2.1"Aluminum1/2
    NEMA 6P, NEMA 7, NEMA 9, NEMA 13
    7794K140000000
     
    Wobble Stick Actuator
     
    Screw-Terminal Wire Connection
    11 Off or 1 On
    Momentary
    SPDT
    10 amp @ 600V AC, 2.5 amp @ 600V DC600V AC
    600V DC
    480 to 1856.2"42.7"4.1"2.1"Aluminum1/2
    NEMA 6P, NEMA 7, NEMA 9, NEMA 13
    7794K15000000
     

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     
    Gray Powder-Coated Aluminum Housing with Yellow Actuator
     
    3 Circuits Controlled with Lockout
    B606003PST
    Three (40 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1200000000
    B1006003PST
    Three (50 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1300000000
     

    Hazardous Location 30 mm Multifunction Panel-Mount Push-Button Switches

    Image of Product. Black. Front orientation. Push-Button Switches. Hazardous Location 30 mm Multifunction Panel-Mount Push-Button Switches.
    Image of Product. Green/Red. Front orientation. Push-Button Switches. Hazardous Location 30 mm Multifunction Panel-Mount Push-Button Switches.

    Black

    Green/Red

    Rated NEC Classes I, II, and III, these switches have a housing that keeps fire and sparks in, so they won’t ignite gases, vapors, or dust. To save space on your panel, they can control multiple circuits. Install them in a standard panel cutout.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Buttons
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    For Max.
    Panel Thk.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure
    Rating
    Choose an Actuator
    Color
    Each
    Metal Actuator Base with Screw-Terminal Wire Connection—Not Illuminated (600V AC/250V DC Maximum Voltage)
     
    Flush
    22 Off
    2Maintained
    4DPST-NO
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"4 1/8"4NEMA 4X
    Green/Red8828N170000000
    21 Off and 1 On
    2Momentary
    4DPST-1NO/1NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"3 3/4"4NEMA 4X
    Black, Green/Red8828N11000000
    22 On
    2Maintained
    4DPST-NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"4 1/8"4NEMA 4X
    Green/Red8828N18000000
    42 Off and 2 On
    2Momentary
    84PST-2NO/2NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC1 1/2"3 3/4"4NEMA 4X
    Black, Green/Red8828N14000000
     
    Blocks

    Hazardous Location Cable-Pull-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Hazardous Location Cable-Pull-Actuator Emergency Stop Switches.
    Safe to use near ignitable gases and dust, the housing on these switches seals in anything that could ignite flammable material. All are UL listed and CSA certified for use in hazardous locations. Yank the cable anywhere along your line to quickly cut power in emergencies. They have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch. Use the tension indicator to visually confirm that they’re reset correctly.
    Mounting
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Fasteners
    Included
    Hole Dia. (No.
    of Holes)
    Hole Thread Size
    (No. of Holes)
    Features
    Each
    Screw-Terminal Wire Connection
     
    1 Direction (NEMA 4; NEMA 7; NEMA 9; NEMA 13; NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G)
    20011 Off or 1 On
    3SPDT
    10 amp @ 600V AC
    10 amp @ 250V DC
    600V AC
    250V DC
    251/2
    No1/4" (2)5/16"-18 (2)Tension Indicator7543N11000000000
    20022 On
    4DPST-NC
    10 amp @ 600V AC
    10 amp @ 250V DC
    600V AC
    250V DC
    251/2
    No1/4" (2)5/16"-18 (2)Tension Indicator7543N1200000000
     

    Fixed-Set-Point Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Hazardous-Location Flow Switches.
    Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments. Because their set point is fixed, they’re ready to go, making them easy to install. They actuate when your flowing liquid or gas pushes their paddle into a set position. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function accurately.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    1/2 NPT Female1.56.52,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/4"NEMA 4
    UL Listed
    CE Marked
    47565K610000000
    3/4 NPT Female2102,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    47565K62000000
    1 NPT Female3142,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3"NEMA 4
    UL Listed
    CE Marked
    47565K63000000
    2 NPT Female10432,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male4 3/4"NEMA 4
    UL Listed
    CE Marked
    47565K6600000000
     
    Brass Body with Threaded Brass Fittings
    1/2 NPT Female1.56.5250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/4"NEMA 4
    UL Listed
    CE Marked
    47565K31000000
    3/4 NPT Female210250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 3/8"NEMA 4
    UL Listed
    CE Marked
    47565K32000000
    1 NPT Female314250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/2"NEMA 4
    UL Listed
    CE Marked
    47565K33000000
    1 1/4 NPT Female421250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    47565K34000000
    1 1/2 NPT Female633250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 7/8"NEMA 4
    UL Listed
    CE Marked
    47565K35000000
    2 NPT Female1043250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3"NEMA 4
    UL Listed
    CE Marked
    47565K36000000
     

    Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Hazardous-Location Flow Switches.
    UL listed for use where flammable gases or combustible dusts may be present, these flow switches activate or deactivate equipment when your flow rate reaches a set point. Use the adjustment screw to select their set point. They actuate when your flowing liquid or gas pushes their paddle into a certain position determined by the set point. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Mount them horizontally. Rated NEMA 4, they also protect against weather and washdowns.
    These flow switches are calibrated with water and air. You can use them with other liquids and gases, but they may not measure accurately if the viscosity is different from water or air.
    Flow Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    1/2 NPT Female0.04 to 0.750.18 to 2.71,450 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3 5/8"NEMA 4
    UL Listed
    CE Marked
    91445K240000000
     
    Brass Body with Threaded Brass Fittings
    1/2 NPT Female0.04 to 0.750.18 to 2.71,450 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3 5/8"NEMA 4
    UL Listed
    CE Marked
    91445K23000000
     

    Hazardous Location Differential Pressure Switches for Liquids

    Image of Product. Front orientation. Differential Pressure Switches. Hazardous Location Differential Pressure Switches for Liquids.
    Tested and verified by UL and C-UL for use where explosive dust or gas are present, these switches have an explosion-proof enclosure that meets NEMA 7 and 9 standards for hazardous locations. They are often used to indicate a filter is clogged in a pump or cooling system. When the differential pressure reaches your setpoint, these switches can turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    In addition to being UL and C-UL listed, these switches are CE marked, so they also meet European safety standards. All switches are IP and NEMA rated for use outdoors and to protect against some corrosion, dust, and washdowns.
    Pressure Set
    Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Female Pipe Connection
    5 in. H₂O to 80 in. H₂O2.5 in. H₂O225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N110000000
    2 psi to 20 psi0.2 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N12000000
    3 psi to 30 psi0.25 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N13000000
    10 psi to 100 psi0.6 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N14000000
     

    Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Style A. Front orientation. Style A. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Image of Product. Style B. Front orientation. Style B. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.

    Style A

    Style B

    Image of Attribute. Front orientation. Contains Annotated. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall. All are rated NEMA 4 for protection from washdowns. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” or from “on” to “off”.
    Switches with a stainless steel body are more corrosion resistant than switches with a brass body.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Current @
    Voltage
    Float Material
    Trade
    Size
    Thread
    Type
    Gender
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body
    A1
    NPT
    Male0.7350 psi @ 70° F0 to 2201 3/4"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K120000000
    A1
    NPT
    Male0.91,000 psi @ 70° F0 to 2201 3/4"5 amp @ 120V ACPolypropylene
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K63000000
    B1
    NPT
    Male0.5200 psi @ 70° F0 to 2202 7/8"5 amp @ 120V AC304 Stainless Steel
    3/4
    NPT
    MaleNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4
    4909K11000000
     

    Hazardous Location Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Hazardous Location Threaded Temperature Switches.
    Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,89710"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    5032K670000000
    0 to 225±2° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,78410"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    5032K8700000000
     

    Hazardous Location Wall-Mount Temperature Switches

    Image of Product. With Threaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.

    With Threaded

    Probe

    With

    Unthreaded

    Probe

    Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temp.
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Includes
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Stainless Steel Probe—1/2 NPT Male
    30° F to 250° F±5° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    1/2 × 3/4 NPT Adapter Bushing5032K66000000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    5032K8600000000
     
    Switch Mounts