McMaster-Carr logo
    Filter by
    System of Measurement
    Panel Cutout Diameter
    Push-Button Style
    Switch Action
    Industrial Info Compare
    Push-Button Shape
    Actuator Color
    Reset Type
    Number of Circuits Controlled
    Number of Terminals
    Number of Positions
    Bulb Color
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    35 Products

    High-Visibility Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches

    Image of Product. Pull Reset. Front orientation. Emergency Stop Switches. High-Visibility Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Pull Reset.
    Image of Product. Twist Reset. Front orientation. Emergency Stop Switches. High-Visibility Plastic 22 mm Panel-Mount Push-Button-Actuator Emergency Stop Switches, Twist Reset.

    Pull Reset

    Twist Reset

    A base that lights up draws attention to emergency stops. When pushed, these switches immediately cut power. All meet IEC and ISO standards for emergency stop applications. Mount them in a standard panel cutout. Installation requires an additional 9 mm cutout for the illuminated ring.
    Light Pattern
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Max. Voltage
    Bulb Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Each
    Screw-Terminal Wire Connection
     
    Pull Reset
    Continuous Red21 Off and 1 On
    Maintained
    6DPST-1NO/1NC
    Red3 amp @ 240V AC
    0.55 amp @ 125V DC
    600V AC
    600V DC
    24V AC/24V DC1 9/16"1 11/16"48002N15000000
    Continuous White or Continuous Red21 Off and 1 On
    Maintained
    6DPST-1NO/1NC
    Red3 amp @ 240V AC
    0.55 amp @ 125V DC
    600V AC
    600V DC
    24V AC/24V DC1 9/16"1 11/16"48002N16000000
     
    Twist Reset
    Continuous Red21 Off and 1 On
    Maintained
    6DPST-1NO/1NC
    Red3 amp @ 240V AC
    0.55 amp @ 125V DC
    600V AC
    600V DC
    24V AC/24V DC1 9/16"1 11/16"48002N17000000
    Continuous White or Continuous Red21 Off and 1 On
    Maintained
    6DPST-1NO/1NC
    Red3 amp @ 240V AC
    0.55 amp @ 125V DC
    600V AC
    600V DC
    24V AC/24V DC1 9/16"1 11/16"48002N18000000
     
    Blocks

    Low-Profile Limit Switches

    Image of Attribute. Style A. Front orientation. Contains Annotated. Limit Switches. Low-Profile Limit Switches, Plunger Actuator, Style A.
    Image of Attribute. Style C. Front orientation. Contains Annotated. Limit Switches. Low-Profile Limit Switches, Roller Plunger Actuator, Style C.
    Image of Attribute. Style E. Front orientation. Contains Annotated. Limit Switches. Low-Profile Limit Switches, Roller Lever Actuator, Style E.

    Style A

    Style C

    Style E

    Stack these slim switches together, or fit them into tight spaces. They're rated IP67 for protection from temporary submersion. When an object in motion comes into contact with the actuator, it sends a signal to open or close a circuit. These switches have the rapid-closing action of a snap-acting switch, but have a larger actuator for large objects. They’re often used on conveyor systems and elevators.
    Plunger Actuator—Plunger actuators open or close circuits when objects push against them.
    Roller Plunger Actuator—Roller plunger actuators open or close circuits when an object pushes against the roller, which moves the plunger. The roller moves parallel to the mounting direction, so it helps push the plunger even if the force isn’t straight on. The roller also reduces friction during actuation which prevents wear and tear over time.
    Roller Lever Actuator—Roller lever actuators open or close circuits when material moves across the switch. The roller reduces friction during actuation which prevents wear and tear over time.
    Plastic Housing and Powder-Coated Zinc Alloy Housing—Switches with plastic or powder-coated zinc alloy housings are rated NEMA 4 and 13 for protection from washdowns and oil/coolant spraying.
    Housing
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Actuation Torque,
    in·ozf
    Operating Temp.
    Range, ° F
    Actuator
    Ht.
    No. of Wire
    Leads
    Cable Lead
    Lg., ft.
    Lg.
    Ht.
    Dp.
    Housing Material
    Enclosure Rating
    Each
    Plunger Actuator
     
    Wire Lead Connection
    A11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1580.2"431.2"2.2"0.7"PlasticNEMA 4, NEMA 13, IP67
    7076K53000000
    A11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1580.2"431.2"2.2"0.7"Powder-Coated Zinc AlloyNEMA 4, NEMA 13, IP67
    7076K4600000
     
    Roller Plunger Actuator
     
    Wire Lead Connection
    C11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1580.6"431.2"2.2"0.7"PlasticNEMA 4, NEMA 13, IP67
    7076K5400000
    C11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1580.6"431.2"2.2"0.7"Powder-Coated Zinc AlloyNEMA 4, NEMA 13, IP67
    7076K4700000
    C22 Off and 2 On
    Momentary
    DPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1580.6"831.2"2.2"0.7"PlasticNEMA 4, NEMA 13, IP67
    7076K5700000
    C22 Off and 2 On
    Momentary
    DPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1580.6"831.2"2.2"0.7"Powder-Coated Zinc AlloyNEMA 4, NEMA 13, IP67
    7076K51000000
     
    Roller Lever Actuator
     
    Wire Lead Connection
    E11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    25.4-13 to 1582.1"431.2"2.2"0.7"PlasticNEMA 4, NEMA 13, IP67
    7076K5200000
    E11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    25.4-13 to 1582.1"431.2"2.2"0.7"Powder-Coated Zinc AlloyNEMA 4, NEMA 13, IP67
    7076K4500000
    E22 Off and 2 On
    Momentary
    DPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    24-13 to 1582.1"831.2"2.2"0.7"PlasticNEMA 4, NEMA 13, IP67
    7076K56000000
    E22 Off and 2 On
    Momentary
    DPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    24-13 to 1582.1"831.2"2.2"0.7"Powder-Coated Zinc AlloyNEMA 4, NEMA 13, IP67
    7076K4900000
     

    Switch Contact Blocks

    Image of Product. Front orientation. Switch Contact Blocks.
    Make or break an electrical circuit. These contact blocks mount to manual switches and transmit an electrical signal when the switch actuator is engaged. You can stack multiple blocks, so a single switch can control several circuits. This is helpful in setups that require multiple systems to turn on or off at the same time. For example, the switch on a conveyor line could turn off the conveyor and turn on a diverter and alarm.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Wire
    Connection
    For Switch Manufacturer
    Series
    Each
    Schneider Electric—Hermetically Sealed
    11 Off
    2SPST-NO
    Screw Terminal9001K71025K1150000000
    11 On
    2SPST-NC
    Screw Terminal9001K71025K116000000
     
    Square D
    11 Off and 1 On
    2SPDT
    Screw Terminal9001K8230K61100000
     

    Hazardous Location 30 mm Panel-Mount Lever Switches

    Image of Product. Front orientation. Lever Switches. Hazardous Location 30 mm Panel-Mount Lever Switches.
    Made for areas where ignitable gas and vapor may be present, these switches have a housing that seals in anything that could spark flammable material. You'll know they're safe because they're NEC Class 1, Division 2, Groups A, B, C, and D certified for hazardous locations. They're also UL and C-UL listed and CSA certified. They require you to grip and twist a lever to turn them on or off, so they won’t accidentally actuate if you bump into them. Mount into a standard panel cutout.
    Actuator
    Color
    Lever
    Lg.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure
    Rating
    Each
    2 Positions
     
    Screw-Terminal Wire Connection
    Black1 1/16"11 Off
    Momentary
    2SPST-NO
    1.5 amp @ 120V AC, 0.55 amp @ 125V DC600V AC
    300V DC
    1 3/8"3 1/16"2IP65
    6982N130000000
    Black1 1/16"11 Off
    Maintained
    2SPST-NO
    1.5 amp @ 120V AC, 0.55 amp @ 125V DC600V AC
    300V DC
    1 3/8"3 1/16"2IP65
    6982N14000000
    Black1 1/16"11 On
    Momentary
    2SPST-NC
    1.5 amp @ 120V AC, 0.55 amp @ 125V DC600V AC
    300V DC
    1 3/8"3 1/16"2IP65
    6982N21000000
    Black1 1/16"11 On
    Maintained
    2SPST-NC
    1.5 amp @ 120V AC, 0.55 amp @ 125V DC600V AC
    300V DC
    1 3/8"3 1/16"2IP65
    6982N22000000
     
    3 Positions
     
    Screw-Terminal Wire Connection
    Black1 1/16"22 Off
    Maintained
    4DPST-NO
    1.5 amp @ 120V AC, 0.55 amp @ 125V DC600V AC
    300V DC
    1 3/8"3 1/16"2IP65
    6982N15000000
     
    Blocks

    30 mm Multifunction Panel-Mount Push-Button Switches

    Image of Product. Front orientation. Not Illuminated. 30 mm Multifunction Panel-Mount Push-Button Switches.
    Image of Product. Front orientation. Illuminated. 30 mm Multifunction Panel-Mount Push-Button Switches.
    Save space on a panel by using one switch to perform multiple functions. These switches are rated NEMA 4, 4X, and 13 for protection from corrosion, washdowns, and oil/coolant spraying. They include enough contact blocks to control the number of circuits listed.
    Note: If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    Illuminated—Illuminated switches have the message "On," which lights up in red when equipment is started.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Buttons
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Message (Actuator Color)
    Switching Current @ Voltage
    For Max.
    Panel Thk.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Bulb Voltage
    Enclosure Rating
    Each
    Metal Actuator Base with Screw-Terminal Wire Connection—Not Illuminated (600V AC/600V DC Maximum Voltage)
     
    Projecting
    21 Off and 1 On
    2Momentary
    4DPDT
    Start (Green), Stop (Red)6 amp @ 120V AC, 0.55 amp @ 125V DC1/4"1 7/8"6NEMA 4, NEMA 4X, NEMA 13
    8230K270000000
     
    Metal Actuator Base with Screw-Terminal Wire Connection—Illuminated (600V AC/600V DC Maximum Voltage)
     
    Projecting
    11 Off and 1 On
    2Maintained
    4SPDT
    Start (Green), On (Red), Stop (Red)6 amp @ 120V AC, 0.55 amp @ 125V DC1/4"2"6110V AC/120V ACNEMA 4, NEMA 4X, NEMA 13
    8230K28000000
     
    Blocks

    Sealed Low-Profile Limit Switches

    Image of Product. Style A. Front orientation. Contains Annotated. Limit Switches. Sealed Low-Profile Limit Switches, Plunger Actuator, Style A.

    Style A

    A sealed actuator prevents these switches from jamming, even when exposed to sand, mud, or dirt. They're also rated IP67 for temporary submersion. With a slim design, you can stack them or fit them in tight spaces. When an object in motion comes into contact with the actuator, it sends a signal to open or close a circuit. These switches have the rapid-closing action of a snap-acting switch, but with a larger actuator. This makes them a good choice for use with large objects. For instance, a box on a conveyor runs into the switch, stopping the conveyor.
    Plunger Actuator—Switches with a plunger actuator require a push to actuate, similar to a button.
    Plastic Housing and Powder-Coated Zinc Alloy Housing—Switches with a powder-coated zinc alloy or plastic housing are rated NEMA 4 and 13 for protection from washdowns and oil/coolant spraying.
    Housing
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Operating Temp.
    Range, ° F
    Actuator
    Ht.
    No. of Wire
    Leads
    Cable Lead
    Lg., ft.
    Lg.
    Ht.
    Dp.
    Housing Material
    Enclosure Rating
    Each
    Plunger Actuator
     
    Wire Lead Connection
    A11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1581.3"431.2"2.2"0.7"PlasticNEMA 4, NEMA 13, IP67
    7076K55000000
    A11 Off or 1 On
    Momentary
    SPDT
    3 amp @ 240V AC, 0.55 amp @ 125V DC240V AC
    250V DC
    -13 to 1581.3"431.2"2.2"0.7"Powder-Coated Zinc AlloyNEMA 4, NEMA 13, IP67
    7076K4800000
     

    Plastic Enclosed Push-Button Switches

    A protective plastic enclosure resists dents, chips, and cracks, so you can install these switches outside of panels. Mount them on a wall, for example, or tether them to a cord at your workstation. They actuate with a push for quick stops and starts. All are NEMA and IP rated to protect against corrosion, washdowns, and oil/coolant spraying. All have knockouts or integrated conduit connections to make it easy to attach conduit or add cord grips.
    Conduit Knockout Size PG-13.5
    Image of Product. Two Flush Buttons. Front orientation. 2 Buttons. Plastic Enclosed Push-Button Switches, Flush Push Button.

    Two Flush

    Buttons

    Image of Specification. Front orientation. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.
    Image of Specification. Front orientation. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.
    Image of Specification. Front orientation. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.
    Image of Specification. Front orientation. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.

    Image of Specification. Front orientation. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.
    Image of Specification. Front orientation. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Push-Button Switches. Plastic Enclosed Push-Button Switches, Conduit Knockout Size PG-13.5.

    Flush Push Button—Flush buttons are easy to clean and difficult to damage because they mount flat.
    IP67 Enclosure Rating—Switches rated IP67 can also be submerged.
    IP69K Enclosure Rating—Switches rated IP69K can also withstand high-pressure washdowns.
    Mounting
    Actuator Color (Switch
    Designation)
    No. of Circuits
    Controlled per Button
    Switch Starting
    Position
    Switch
    Action
    No. of Terminals
    per Button
    Switching Current @ Voltage
    Max. Voltage
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Enclosure Rating
    Each
    Screw-Terminal Wire Connection
     
    2 Buttons (Flush)
    Green with Start (SPST-NO)
    Red with Stop (SPST-NC)
    11 Off
    Momentary
    26 amp @ 120V AC, 0.55 amp @ 120V DC600V AC
    600V DC
    No23/16"IK03, IP20, IP66, IP67, IP69K, NEMA 4X, NEMA 13
    7546K31000000
     
    Replacement Blocks
    back to top