Choosing an Electrical Switch
More
Enclosed Push-Button Switches for T-Slotted Framing
![]() | ![]() 4-Pole Micro M12 Plug |
![]() 8-Pole Micro M12 Plug |
Snap these switches onto your T-slotted framing rails—no need to drill or disassemble your existing structure. All come with a mounting bracket that fastens directly onto the rail with the included drop-in fasteners. Their built-in clip hooks onto the bracket, so there’s no need to open the housing to mount them. You can adjust their position by sliding them down the rails. With a push button, they’re quick and easy to actuate.


Micro
M12 Plug
For Rail Height | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single | Double, Quad | Triple | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | Mounting Fasteners Included | Each | |
4-Pole Micro M12 Plug | |||||||||||||
Not Illuminated | |||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 White Button (SPST-NO) | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | 1.5 A @ 240 V AC, 2 A @ 24 V DC | 24V DC 240V AC | __ | Yes | 0000000 | 0000000 |
Illuminated | |||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 White Button (SPST-NO) | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | 1.5 A @ 240 V AC, 2 A @ 24 V DC | 24V DC 240V AC | 24V DC 240V AC | Yes | 0000000 | 000000 |


Micro
M12 Plug

Micro
M12 Plug
For Rail Height | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single | Double, Quad | Triple | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Max. Voltage | Bulb Voltage | Mounting Fasteners Included | Each | |
4-Pole Micro M12 Plug | |||||||||||||
Not Illuminated | |||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 2 White Buttons (SPST-NO) | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | 1.5 A @ 240 V AC, 2 A @ 24 V DC | 24V DC 240V AC | __ | Yes | 0000000 | 0000000 |
8-Pole Micro M12 Plug | |||||||||||||
Illuminated | |||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 Green Button (SPST-NO), 1 Red Button (SPST-NO) | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | 1.5 A @ 240 V AC, 2 A @ 24 V DC | 24V DC 240V AC | 24V DC 240V AC | Yes | 0000000 | 000000 |
Emergency Stop Enclosed Push-Button Switches for T-Slotted Framing


Micro
M12 Plug

Micro
M12 Plug

Micro
M12 Plug
Clip these switches onto nearby structures made from T-slotted framing to quickly cut power with the push of a button. These switches meet EN 60947-5-1 and EN 60947-5-5, so they comply with European safety standards for reliably stopping machines.
You don’t need to take apart your existing structure or open the switch’s plastic housing to mount them. Fasten the included bracket to a rail with the included drop-in fasteners, then clip the switch onto the bracket.
Switches with two buttons have one button for an emergency stop and another button that can be wired to any equipment nearby.


Micro
M12 Plug

Micro
M12 Plug

Micro
M12 Plug
For Rail Height | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Single | Double, Quad | Triple | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Max. Voltage | Mounting Fasteners Included | Each | |
4-Pole Micro M12 Plug | ||||||||||||
Turn Reset | ||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 Red Button (DPST-NC) | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 1.5 A @ 240 V AC, 2 A @ 24 V DC | 60V DC 240V AC | Yes | 0000000 | 0000000 |
5-Pole Micro M12 Plug | ||||||||||||
Turn Reset | ||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 Red Button (DPST-NC) | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 1.5 A @ 240 V AC, 2 A @ 24 V DC | 60V DC 240V AC | Yes | 0000000 | 000000 |
8-Pole Micro M12 Plug | ||||||||||||
Turn Reset | ||||||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 Red Button (DPST-NC) | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 1.5 A @ 24 V DC | 24V DC | Yes | 0000000 | 000000 |


Micro
M12 Plug
For Rail Height | |||||||||
---|---|---|---|---|---|---|---|---|---|
Single | Double, Quad | Triple | Actuator Color (Industry Designation) | Switch Action | Switching Current @ Voltage | Max. Voltage | Mounting Fasteners Included | Each | |
8-Pole Micro M12 Plug | |||||||||
Push Reset and Turn Reset | |||||||||
1 1/2", 40mm | 3", 80mm | 4 1/2", 120mm | 1 White Button (SPST-NO) 1 Red Button (DPST-NC) | Stays Switched (Maintained) | 1.5 A @ 24 V DC | 24V DC | Yes | 0000000 | 0000000 |
Hazardous Location 30 mm Panel-Mount Lever Switches
Made for areas where ignitable gas and vapor may be present, these switches have a housing that seals in anything that could spark flammable material. You'll know they're safe because they're NEC Class 1, Division 2, Groups A, B, C, and D certified for hazardous locations. They're also UL and C-UL listed and CSA certified. They require you to grip and twist a lever to turn them on or off, so they won’t accidentally actuate if you bump into them. Mount into a standard panel cutout.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

Lever Lg. | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Each | |
2 Position | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | ||||||||||||
1 1/16" | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 0000000 |
1 1/16" | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
1 1/16" | 1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | SPST-NC | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
1 1/16" | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
3 Position | ||||||||||||
With Screw Terminals | ||||||||||||
1 1/16" | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
Safety Limit Switches


Protect machinery and ensure the safety of personnel—these switches have positive-force contacts that will open the circuit when actuated even if a spring fails or the contacts stick. When an object in motion comes into contact with the actuator, it sends a signal to open or close a circuit. These switches have the rapid-closing action of a snap-acting switch, but with a larger actuator. This makes them a good choice for use with large objects—for instance, a box on a conveyor runs into the switch, stopping the conveyor.
Switches with a roller lever actuator use a lever with a roller at the end to activate. This allows parts to glide across the actuation surface with minimal friction, limiting wear and tear on your switch.
Switches with a rod actuator use a rod extending out of the body to actuate, so they’ll activate even if an object is far away.
Styles D, E, and F have an actuator that allows you to adjust its height, making it easier to align switch with the target during installation.
Switches with a steel actuator are more durable than switches with a plastic actuator. They also handle higher loads.
Switches with a plastic actuator limit wear and tear on passing objects better than switches with a steel actuator.
For technical drawings and 3-D models, click on a part number.
Housing | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Actuator Material | Switching Current @ Voltage | Max. Voltage | Operating Temp. Range, °F | Actuator Ht. | Wire Connection Type | Lg. | Ht. | Dp. | Housing Material | Environmental Rating | Each | |
Roller Lever Actuator Style | |||||||||||||||||
C | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Plastic | 3 A @ 240 V AC, 1.5 A @ 24 V DC | 240V AC 24V DC | -22° to 165° | 1.5" | Screw Terminals | 1.7" | 2.9" | 1.6" | Plastic | NEMA 4X, IP66, IP67 | 00000000 | 0000000 |
Rod Actuator Style | |||||||||||||||||
F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Steel | 3 A @ 240 V AC, 1.5 A @ 24 V DC | 240V AC 24V DC | -22° to 165° | 0.5"-8" | Screw Terminals | 1.7" | 2.9" | 1.6" | Plastic | NEMA 4X, IP66, IP67 | 00000000 | 000000 |
Potentiometers

Vary electrical flow to control speed, volume, and light intensity. The number of turns affects the resolution—the higher the number, the better the control. Also known as variable output switches. A knob is required (not included).

Safety Relays with Diagnostic Capabilities
Control and diagnose issues with safety-critical circuits. These relays have a microprocessor that monitors safety components, such as emergency stops and light curtains, and sends a signal to stop the operation if a failure is detected and restart when the issue is resolved. They also help with diagnostic tasks because of their feedback circuit, which allows basic relays to communicate their status back to the safety relay. These relays have a duplicate set of input and output signals, so they’ll still stop the controlled device if one of the inputs fails.
IP20 rated, they have recessed terminals which prevent fingers and other objects from touching live circuits. These relays have been tested to multiple safety standards and can help achieve PL, SIL, or CAT system ratings. They also meet ISO and IEC standards for machine safety.
Mount them to 35 mm DIN rail (also known as DIN 3 Rail) for fast installation.
Auxiliary contact blocks (sold separately) allow you to control more components, such as signaling devices or basic relays.
For technical drawings and 3-D models, click on a part number.

Number of Terminals | Input Voltage | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | For Use With | Max. System Safety Rating | Features | Each | |
2 Circuits Controlled | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
2 Off (Normally Open) | |||||||||||
14 | 24V DC | 2 A @ 240 V AC 1.5 A @ 24 V DC | 250V AC | 4.9" | 0.69" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 0000000 |
4 Circuits Controlled | |||||||||||
4 Off (Normally Open) | |||||||||||
18 | 24V DC | 2 A @ 240 V AC 1.5 A @ 24 V DC | 250V AC | 4.9" | 0.89" | 4.3" | Emergency Stops, Light Curtains | PLe, SIL3, CAT 4, 250V | Auxiliary PNP Output, LED Indicator | 0000000 | 000000 |


Number of Terminals | Input Voltage | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
5 Safety Outputs | |||||||||
---|---|---|---|---|---|---|---|---|---|
16 | 24V AC, 24V DC | 2.5 A @ 24 V DC 3 A @ 240 V AC | 250V AC, 250V DC | 3.9" | 0.9" | 4.5" | __ | 0000000 | 0000000 |
4 Delayed Safety Outputs | |||||||||
16 | 24V DC | 3 A @ 240 V AC 3 A @ 24 V DC | 250V AC, 250V DC | 3.9" | 0.9" | 4.5" | Time Delay | 0000000 | 000000 |