High-Current Wall-Mount Timer Switches
Control equipment with high currents such as air conditioners, heaters, and ventilating equipment. They automatically turn electrical equipment on or off after a set interval of time.
Switches with override can bypass the automatic shut-off.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Includes | Wire Connection Type | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Without Override | |||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Replacement Knob | 0000000 | Each | 00000 |
DIN-Rail Mount Touch-Safe Screw Terminal Relays
Quickly and safely mount these relays on 35 mm DIN rail (also known as DIN 3). IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits.
Relays that control 3 and 4 circuits are built to IEC dimensional standards and are often called IEC contactors.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay. You can add one auxiliary contact to all of these relays. For relays with 12 terminals, you can add two side-mount auxiliary contacts.
For technical drawings and 3-D models, click on a part number.
Control | hp @ Switching Voltage | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Power | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||
With 1 Auxiliary Contact—1 Off (Normally Open) | |||||||||||
12 | 24V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 24V DC | 5.4W | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
With 1 Auxiliary Contact—1 On (Normally Closed) | |||||||||||
12 | 24V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 24V DC | 5.4W | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | |||||||||||
12 | 24V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 11 A @ 600 V AC (Full Load) 28 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 5 hp @ 240 V AC 7 1/2 hp @ 480 V AC 10 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |