McMaster-Carr logo
    Filter by
    System of Measurement
    Electrical Phase
    Number of Circuits Controlled
    Number of Terminals
    Actuator Style
    Switch Action
    Industrial Info Compare
    Actuator Color
    Number of Mounting Holes
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    106 Products

    Motor Switches

    Image of Product. Front orientation. Motor Switches. Motor Switches, Toggle Switch Actuator.

    Toggle

    Switch

    Actuator

    Use these switches to turn motors on and off, or to control lighting and electric heat circuits. They do not provide overload protection.
    Toggle Switch Actuator—Toggle switches work like a traditional light switch—just flip the toggle up or down. Even if you’re wearing thick gloves, they’re easy to actuate.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Ht.
    Wd.
    Wire
    Connection
    Certification
    Each
    Maintained
     
    Toggle Switch Actuator
    2Single (5 hp @ 240V AC)2 Off
    DPST-NO
    406003.7"1.8"Screw TerminalUL Listed, CSA Certified
    7858N21000000
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    406003.7"1.8"Screw TerminalUL Listed, CSA Certified
    7858N22000000
     

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Single (3 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    40600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N130000000
     

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K5110000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K512000000
     
    Labels

    Washdown Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Use additional switch power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Switch with Plastic Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Plastic Housing.
    Image of Product. Switch with Lockout and Plastic Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled with Lockout.
    Image of Product. Switch with Lockout and Stainless Steel Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Stainless Steel Housing, 3 Circuits Controlled with Lockout.

    Switch with

    Plastic Housing

    Switch with

    Lockout and

    Plastic Housing

    Switch with Lockout

    and Stainless Steel

    Housing

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    IP66 Enclosure Rating—The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    6 7/8"4 1/2"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K12000000
     
    Stainless Steel Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K62000000
     
    Accessories for Disconnect Switches

    DIN-Rail Mount Solid State Relays

    Image of Product. Relay with Integrated Heat Sink. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Solid State Relays.
    Image of Product. Relay with Integrated Heat Sink and Fan. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Solid State Relays.
    Image of Product. Relay. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Solid State Relays.

    Relay with

    Integrated Heat

    Sink

    Relay with Integrated Heat

    Sink and Fan

    Relay

    Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, switch faster, and are quieter. They mount on 35 mm DIN rail (also known as DIN 3) for fast installation. An LED indicator lights up when these relays are connected, so you can quickly confirm that they’re wired correctly. IP20 rated, their terminals are recessed, so they prevent fingers and other objects from touching live circuits.
    Integrated Heat Sink—Relays with an integrated heat sink disperse heat to increase the relay’s current rating.
    Integrated Fan—Relays with an integrated fan are best for applications that generate more heat. The fan automatically turns on to provide additional cooling. When the temperature exceeds 176° F, an alarm sends a signal to an external device, such as a controller or indicating light.
    No. of
    Terminals
    Input Voltage
    Control Current,
    mA
    Switching Current @
    Voltage (Load Type)
    Max. Switching
    Voltage, V AC
    hp @ Switching Voltage
    Ht.
    Wd.
    Dp.
    Features
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Single Phase
    424V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC2240 amp @ 600V AC (Full)6601 hp @ 115V AC
    3 hp @ 230V AC
    4.33"1.4"4.917"Integrated Heat Sink, LED Indicator6323T340000000
    44V DC, 6V DC, 12V DC, 24V DC, 30V DC1340 amp @ 600V AC (Full)6601 hp @ 115V AC
    3 hp @ 230V AC
    4.33"1.4"4.917"Integrated Heat Sink, LED Indicator6323T33000000
     
    2 Circuits Controlled with 2 Off—DPST-NO
     
    Three Phase
    824V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC240 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    4.33"2.84"4.66"Integrated Heat Sink, LED Indicator6323T83000000
    85V DC, 6V DC, 12V DC, 24V DC, 30V DC1040 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    4.33"2.84"4.66"Integrated Heat Sink, LED Indicator6323T84000000
     
    3 Circuits Controlled with 3 Off—3PST-NO
     
    Three Phase
    1524V AC, 120V AC, 208V AC, 240V AC, 277V AC/24V DC, 48V DC, 60V DC, 120V DC240 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    5.31"2.13"3.739"Integrated Heat Sink, Integrated Fan, LED Indicator6323T89000000
    155V DC, 6V DC, 12V DC, 24V DC, 30V DC1040 amp @ 600V AC (Full)6605 hp @ 230V AC
    10 hp @ 480V AC
    5.31"2.13"3.739"Integrated Heat Sink, Integrated Fan, LED Indicator6323T91000000
     

    High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. High-Current Time and Day Activated Switches.
    Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, hr.
    Tripper
    Type
    No. of
    Trippers
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Environment
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    140 amp @ 240V AC120121Removable2SPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K110000001 Pair7037K3200000
    240 amp @ 240V AC120121Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K13000001 Pair7037K320000
    240 amp @ 240V AC208/240/277121Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K140000001 Pair7037K320000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    140 amp @ 240V AC120101Removable2SPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K17000001 Pair7037K420000
    240 amp @ 240V AC120101Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K190000001 Pair7037K420000
    240 amp @ 240V AC208/240/277101Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K210000001 Pair7037K420000
     
    7-Day Timing Cycle
    440 amp @ 240V AC12033.5Removable44PST-NO
    12 1/2"8 1/4"4"Screw TerminalIndoor Only79915K660000007 Pair79915K7100000
     
    Screws

    Infrequent-Cycle Relays

    Image of Product. 1 Circuit. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 2 Terminals.
    Image of Product. 2 Circuits. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 4 Terminals.
    Image of Product. 3 Circuits. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 6 Terminals.
    Image of Product. 4 Circuits. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Infrequent-Cycle Relays, 8 Terminals.

    1 Circuit

    2 Circuits

    3 Circuits

    4 Circuits

    For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
    Auxiliary contacts for 3.8"-7.2" Ht. relays are also available. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on or off.
    Switching Current
    @ 600V AC, amp
    hp @
    Switching Voltage
    No. of
    Terminals
    Input Voltage
    Control
    Power
    Full
    Load
    Resistive
    Load
    Single Phase
    Three Phase
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Quick-Disconnect × Screw Terminal
    224V AC6 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K724000000
    224V AC6 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K861000000
    2120V AC6 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K72500000
    2120V AC6 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K862000000
    2208V AC, 240V AC6 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K72600000
    2208V AC, 240V AC6 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K863000000
     
    2 Circuits Controlled with 2 Off—DPST-NO
     
    Quick-Disconnect × Screw Terminal
    424V AC6.5 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K75400000
    424V AC6.5 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K764000000
    4120V AC6.5 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K75500000
    4120V AC6.5 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K765000000
    4208V AC, 240V AC6.5 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    3.2"2"2.3"0.25"6564K75600000
    4208V AC, 240V AC6.5 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.2"2"2.3"0.25"6564K766000000
    424V DC3.1 W30402 hp @ 115V AC
    5 hp @ 230V AC
    3.8"2.4"3.4"0.25"6564K516000000
    424V DC3.1 W40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    3.8"2.4"3.4"0.25"6564K519000000
     
    3 Circuits Controlled with 3 Off—3PST-NO
     
    Quick-Disconnect × Screw Terminal
    624V AC7 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K941000000
    624V AC7 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K951000000
    6120V AC7 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K942000000
    6120V AC7 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K952000000
    6208V AC, 240V AC7 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K943000000
    6208V AC, 240V AC7 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K953000000
    624V DC3.1 W30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K517000000
    624V DC3.1 W40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.4"3.4"0.25"6564K521000000
     
    4 Circuits Controlled with 4 Off—4PST-NO
     
    Quick-Disconnect × Screw Terminal
    824V AC50.4 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K201000000
    824V AC50.4 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K301000000
    8120V AC50.4 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K202000000
    8120V AC50.4 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K302000000
    8208V AC, 240V AC50.4 VA30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K203000000
    8208V AC, 240V AC50.4 VA40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K303000000
    824V DC5.1 W30402 hp @ 115V AC
    5 hp @ 230V AC
    10 hp @ 230V AC
    15 hp @ 460V AC
    15 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K518000000
    824V DC5.1 W40503 hp @ 115V AC
    7 1/2 hp @ 230V AC
    10 hp @ 230V AC
    20 hp @ 460V AC
    20 hp @ 575V AC
    3.8"2.7"3.4"0.25"6564K522000000
     
    Enclosures

    Vehicle Relays

    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket Mount, 4 Terminals.
    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket and Surface Mount, 4 Terminals.
    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket Mount, 5 Terminals.

    Relay-Socket

    Mount, 4

    Terminals

    Relay-Socket and

    Surface Mount, 4

    Terminals

    Relay-Socket

    Mount, 5

    Terminals

    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket and Surface Mount, 5 Terminals.
    Image of Product. Front orientation. Relay Sockets. Vehicle Relays, Sockets with Crimp- On Terminals.
    Image of Product. Front orientation. Relay Sockets. Vehicle Relays, Sockets with Wire Leads.

    Relay-Socket and

    Surface Mount, 5

    Terminals

    Sockets with

    Crimp- On

    Terminals

    Sockets with Wire

    Leads

    These relays handle the high starting (inrush) currents that often occur when turning on a vehicle. Also known as ISO relays, their blade terminals meet ISO 8092-1 dimensional standards to fit in road vehicles for easy maintenance and repair.
    Relays with surge suppression coverage prevent damage to sensitive equipment by reducing the 300V to 500V spike that happens when you switch relays off.
    Surface Mount—Relays for surface mounting have a tab for added security in high-vibration applications.
    Partial—Relays with partial surge suppression coverage bring this spike down to 100V.
    Full—Relays with full surge suppression coverage eliminate the voltage spike.
    Dual Output—Relays with dual output let you control two separate loads or circuits independently. For example, in a car window, these relays could control it moving up and down.
    Vehicle Relays
    Sockets with
    Crimp- On Terminals
    Sockets with
    Wire Leads
    Switching Current @ Voltage
    No. of
    Terminals
    Input Voltage,
    V DC
    Off (Normally Open)
    Circuit Position
    On (Normally Closed)
    Circuit Position
    Max. Switching
    Voltage, V DC
    Max. Starting
    Current, amp
    Control Current,
    mA
    Surge Suppression
    Coverage
    Relay Terminal
    Layout
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Features
    Each
    Each
    Each
    Relay-Socket Mount
     
    1 Circuit Controlled with 1 Off—SPST-NO
    41240 amp @ 12V DC18150155PartialType B1"1"0.9"0.25"9672K1130000008228K42000008228K13000000
    41240 amp @ 12V DC20150141Type B1"1"0.9"0.25"9672K115000008228K4200008228K1300000
    51240 amp @ 12V DC20150141Type B1"1"0.9"0.25"Dual Output9672K114000008228K4200008228K1300000
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51240 amp @ 12V DC20 amp @ 12V DC18150133FullType B1"1"0.9"0.25"9672K106000008228K4200008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC18150155PartialType B1"1"0.9"0.25"9672K107000008228K4200008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC20150141Type B1"1"0.9"0.25"9672K105000008228K4200008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC20150163PartialType B1"1"0.9"0.25"9672K108000008228K4200008228K1300000
     
    Relay-Socket and Surface Mount
     
    1 Circuit Controlled with 1 Off—SPST-NO
    41240 amp @ 12V DC18150155PartialType B1"1"0.9"0.25"9672K112000008228K4200008228K1400000
    51240 amp @ 12V DC20150141Type B1"1"0.9"0.25"Dual Output9672K29000008228K4200008228K1400000
    51240 amp @ 12V DC20150141FullType B1"1"0.9"0.25"Dual Output9672K116000008228K4200008228K1400000
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51240 amp @ 12V DC20 amp @ 12V DC20150141Type B1"1"0.9"0.25"9672K109000008228K4200008228K1400000
    51240 amp @ 12V DC20 amp @ 12V DC20150163PartialType B1"1"0.9"0.25"9672K111000008228K4200008228K1400000
     

    Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays

    Image of Product. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays, 10 Terminals.
    Image of Product. Front orientation. Contains Annotated. Infrequent-Cycle Relays. Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays, 12 Terminals.

    10 Terminals

    12 Terminals

    Operate equipment that cycles on and off from your control cabinet. Often called definite-purpose contactors, these relays meet UL 508 for use with air conditioning and heating. Mount them directly to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They have recessed terminals that prevent fingers and other objects from touching live circuits. You can wire the control circuit on either side of the relay, which helps you use less wire.
    Switching Current
    @ 600V AC, amp
    hp @
    Switching Voltage
    No. of
    Terminals
    Input
    Voltage
    Control
    Power
    Full
    Load
    Resistive
    Load
    Max. Switching
    Voltage, V AC
    Single Phase
    Three Phase
    Ht.
    Wd.
    Dp.
    Each
     
    3 Circuits Controlled with 3 Off—3PST-NO
    1024V AC9 VA40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"1.8"3.5"9114T3510000000
    10120V AC9 VA40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"1.8"3.5"9114T352000000
    10240V AC9 VA40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"1.8"3.5"9114T353000000
    1024V DC5.4 W40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"1.8"4.2"9114T45000000
     
    4 Circuits Controlled with 4 Off—4PST-NO
    1224V AC9 VA40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"2.4"3.5"9114T411000000
    12120V AC9 VA40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"2.4"3.5"9114T412000000
    12240V AC9 VA40506003 hp @ 120V AC
    7 1/2 hp @ 240V AC
    10 hp @ 240V AC
    30 hp @ 480V AC
    40 hp @ 600V AC
    3.5"2.4"3.5"9114T413000000
     
    Accessories and Replacements for Infrequent-Cycle Relays

    Weatherproof Vehicle Relays

    Image of Product. Front orientation. Contains Annotated. Vehicle Relays. Weatherproof Vehicle Relays, Relay-Socket Mount.
    Image of Product. Front orientation. Contains Annotated. Vehicle Relays. Weatherproof Vehicle Relays, Relay-Socket and Surface Mount.
    Image of Product. Front orientation. Relay Sockets. Weatherproof Vehicle Relays, Sockets with Crimp- On Terminals.
    Image of Product. Front orientation. Relay Sockets. Weatherproof Vehicle Relays, Sockets with Wire Leads.

    Relay-Socket Mount

    Relay-Socket and

    Surface Mount

    Sockets

    with

    Crimp- On

    Terminals

    Sockets with Wire Leads

    An extended housing shields the terminals on these relays from weather. They're also rated IP54—when they're plugged into the relay socket, they're sealed to keep splashing water, like rain, from getting inside. They handle high starting (inrush) currents that often occur when turning on a vehicle. To prevent damage to sensitive equipment, these relays will partially suppress a momentary surge in voltage when the relay switches off. They’ll take a voltage spike of 300V to 500V and bring it down to 100V.
    Surface Mount—Relays for surface mounting have a tab for added security in high-vibration applications.
    Vehicle Relays
    Sockets with
    Crimp- On Terminals
    Sockets with
    Wire Leads
    Switching Current @ Voltage
    No. of
    Terminals
    Input Voltage,
    V DC
    Off (Normally Open)
    Circuit Position
    On (Normally Closed)
    Circuit Position
    Max. Switching
    Voltage, V DC
    Max. Starting
    Current, amp
    Control Current,
    mA
    Surge Suppression
    Coverage
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Features
    Each
    Each
    Each
    Relay-Socket Mount
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51240 amp @ 12V DC20 amp @ 12V DC18150114Partial1.4"1.4"1.8"0.11"Extended Housing9672K302000000———09672K304000000
    51240 amp @ 12V DC20 amp @ 12V DC18150155Partial1.4"1.4"1.8"0.25"Extended Housing9672K301000008228K190000008228K1500000
     
    Relay-Socket and Surface Mount
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51240 amp @ 12V DC20 amp @ 12V DC18150114Partial1.4"1.4"1.8"0.11"Extended Housing9672K30300000———09672K30400000
    51240 amp @ 12V DC20 amp @ 12V DC18150138Partial1.4"1.4"1.8"0.25"Extended Housing9672K44000008228K19000008228K1500000
     

    Outdoor High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Tripper
    Type
    No. of
    Trippers
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    140 amp @ 240V AC120121 hr.Removable2SteelSPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K8100000001 Pair7037K3200000
    240 amp @ 240V AC120/208/240/2774815 min.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal7037K1500000———0
    240 amp @ 240V AC120121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K830000001 Pair7037K320000
    240 amp @ 240V AC208/240/277121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K840000001 Pair7037K320000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    240 amp @ 240V AC120101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K890000001 Pair7037K420000
    240 amp @ 240V AC208/240/277101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K910000001 Pair7037K420000
     
    7-Day Timing Cycle
    240 amp @ 240V AC120/208/240/27762 hr.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal79915K59000000———0
    440 amp @ 240V AC12033.5 hr.Removable14Steel4PST
    12 1/2"8 1/4"4"Screw Terminal79915K680000007 Pair79915K7100000
     
    Screws